Detective quantum efficiency [DQE(0)] of CZT semiconductor detectors for digital radiography

被引:1
作者
Giakos, GC [1 ]
Suryanarayanan, S
Guntupalli, R
Odogba, J
Shah, N
Vedantham, S
Chowdhury, S
Mehta, K
Sumrain, S
Patnekar, N
Moholkar, A
Kumar, V
Endorf, RE
机构
[1] Univ Akron, Dept Elect & Comp Engn, Imaging Syst Detectors & Sensors Lab, Akron, OH 44325 USA
[2] Univ Akron, Dept Biomed Engn, Akron, OH 44325 USA
[3] Univ Akron, Div Engn & Appl Math, Akron, OH 44325 USA
[4] Univ Cincinnati, Dept Phys, Cincinnati, OH 45221 USA
关键词
detective quantum efficiency; digital radiography; semiconductor detectors;
D O I
10.1109/TIM.2004.834590
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the detective quantum efficiency (DQE) of cadmium zinc telluride (CZT) detector samples for digital radiography has been measured. Specifically, this study is aimed at investigating the zero-frequency DQE(0) under different X-ray tube and detector parameters. The experimental results of this study indicate that the DQE(0) of the CZT samples is strongly dependent upon the irradiation geometry. This is attributed to the incomplete charge collection process, which can be further improved by controlling the purity of the samples and the contact type.
引用
收藏
页码:1479 / 1484
页数:6
相关论文
共 30 条
  • [1] Allison D, 1997, IEEE NUCL SCI CONF R, P1248
  • [2] Antonuk LE, 1998, RADIOLOGY, V209P, P357
  • [3] Antonuk LE, 1998, RADIOLOGY, V209P, P358
  • [4] A REAL-TIME, FLAT-PANEL, AMORPHOUS-SILICON, DIGITAL X-RAY IMAGER
    ANTONUK, LE
    YORKSTON, J
    HUANG, WD
    SIEWERDSEN, JH
    BOUDRY, JM
    ELMOHRI, Y
    MARX, MV
    [J]. RADIOGRAPHICS, 1995, 15 (04) : 993 - 1000
  • [5] BREAST IMAGING - DUAL-ENERGY PROJECTION RADIOGRAPHY WITH DIGITAL RADIOGRAPHY
    ASAGA, T
    CHIYASU, S
    MASTUDA, S
    MASTUURA, H
    KATO, H
    ISHIDA, M
    KOMAKI, T
    [J]. RADIOLOGY, 1987, 164 (03) : 869 - 870
  • [6] A physical image quality evaluation of a CCD-based X-ray image intensifier digital fluorography system for cardiac applications
    Baker, EL
    Cowen, AR
    Kemner, R
    Bastiaens, R
    [J]. PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 430 - 441
  • [7] Performance characteristics of a Kodak computed radiography system
    Bradford, CD
    Peppler, WW
    Dobbins, JT
    [J]. MEDICAL PHYSICS, 1999, 26 (01) : 27 - 37
  • [8] CD1-XZNXTE4 GAMMA-RAY DETECTORS
    BUTLER, JF
    LINGREN, CL
    DOTY, FP
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) : 605 - 609
  • [9] BUTLER JF, 1994, INT SOC OPT ENG P SP, V2009, P121
  • [10] BUTLER JF, 1993, SPIE, V1896, P30