Radiation Exposure from Fluoroscopy during Hip Arthroscopy

被引:2
作者
Seijas, Roberto [1 ,2 ,3 ]
Catala, Jordi [4 ]
Cepas, Miguel Angel [5 ]
Sallent, Andrea [6 ]
Ares, Oscar [7 ]
Barastegui, David [1 ,2 ,8 ]
机构
[1] Hosp Quiron, Inst Cugat, Dept Orthoped Surg, Barcelona, Spain
[2] Garcia Cugat Fdn, Barcelona, Spain
[3] Univ Int Catalunya, Dept Anat, Barcelona, Spain
[4] Inst Guirado, Dept Radiol, Barcelona, Spain
[5] Hosp Quiron, Barcelona, Spain
[6] Hosp Valle De Hebron, Dept Orthoped, Barcelona, Spain
[7] Hosp Clin Barcelona, Dept Orthoped & Trauma, Barcelona, Spain
[8] Mutualitat Catalana Futbolistes, Barcelona, Spain
关键词
femoroacetabular impingement; hip arthroscopy; fluoroscopy; radiation exposure; ESTABLISHMENT;
D O I
10.1055/s-0039-3400278
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective Hip arthroscopy for femoroacetabular impingement treatment is a procedure that is not exempted from complications. The most common complications are related to the arthroscopic portals and the traction system. The use of fluoroscopy helps in hip arthroscopy; however, the radiation exposure is a risk that has not yet been studied. Materials and Methods A retrospective study with 100 arthroscopies was performed. Surgical indication in all cases was femoroacetabular impingement. Surgical times and radiation exposure during the procedure had been recorded and reviewed for the present study. Results A mean of 138.20 cGy cm (2) radiation exposures was observed per patient and procedure for a mean time of radiation exposure of 0.36 minutes. These values are much lower than the values described as being at risk by the nuclear security commissions. Conclusions Radiation exposure in a hip arthroscopy due to femoroacetabular impingement is in margins well below the limits at risk for the patient.
引用
收藏
页码:E184 / E187
页数:4
相关论文
共 50 条
[41]   Factors influencing radiation exposure during internal fixation of hip fractures [J].
Kelly G.A. ;
Rowan F.E. ;
Hurson C. .
European Journal of Orthopaedic Surgery & Traumatology, 2017, 27 (5) :637-641
[42]   Occupational Radiation Exposure During Intraoperative 3-Dimensional Fluoroscopy in Pelvis and Acetabular Surgery [J].
Gosselin, Michelle M. ;
Ngo, Daniel H. ;
Levack, Ashley E. ;
Kutzler, Michael A. ;
Osunbayo, Olaolu ;
Feng, Janet Ching-Mei ;
Gary, Joshua L. ;
Warner, Stephen J. ;
Routt, Milton L. Chip .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2024, 38 (11S) :S29-S34
[43]   Arthroscopy of the hip [J].
Byrd, JWT .
SPORTS MEDICINE AND ARTHROSCOPY REVIEW, 2002, 10 (02) :151-162
[44]   Radiation exposure to the orthopaedic surgical team during fluoroscopy: "How far away is far enough?" [J].
Mehlman, CT ;
DiPasquale, TG .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (06) :392-398
[45]   Hip arthroscopy [J].
Gollwitzer, H. ;
Banke, I. J. ;
Schauwecker, J. .
ORTHOPADE, 2016, 45 (02) :183-193
[46]   Investigation of Radiation Exposure of Medical Staff During Lateral Fluoroscopy for Posterior Spinal Fusion Surgery [J].
Watanabe, Seiya ;
Nakanishi, Kazuo ;
Mura, Masakatsu ;
Yutori, Ato ;
Hitomi, Go ;
Uchino, Kazuya ;
Iba, Hideaki ;
Sugimoto, Yoshihisa ;
Mitani, Shigeru .
JOURNAL OF CLINICAL MEDICINE, 2024, 13 (21)
[47]   Effect of the presence of cysts in the hip joint on hip arthroscopy [J].
Ciceklidag, Murat ;
Ayanoglu, Tacettin ;
Kaptan, Ahmet Yigit ;
Vural, Abdurrahman ;
Kalaycioglu, Oya ;
Ozer, Mustafa ;
Kanatli, Ulunay .
JOINT DISEASES AND RELATED SURGERY, 2024, 35 (03) :645-653
[48]   Reduction of radiation exposure during catheter ablation for paroxysmal supraventricular tachycardia: The effect of a low frame rate of digital pulsed fluoroscopy [J].
Lee, Soo-Yong ;
Kim, Jun ;
Lee, Sang-Hyun ;
Choi, Jin-Hee ;
Kim, Jeong-Su ;
Park, Yong-Hyun ;
Kim, June-Hong ;
Chun, Kook -Jin .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 177 (02) :573-574
[49]   Fluoroscopy integrated 3D mapping significantly reduces radiation exposure during ablation for a wide spectrum of cardiac arrhythmias [J].
Christoph, Marian ;
Wunderlich, Carsten ;
Moebius, Stefanie ;
Forkmann, Mathias ;
Sitzy, Judith ;
Salmas, Jozef ;
Mayer, Julia ;
Huo, Yan ;
Piorkowski, Christopher ;
Gaspar, Thomas .
EUROPACE, 2015, 17 (06) :928-937
[50]   Injections prior to hip arthroscopy are associated with increased risk of repeat hip arthroscopy at 1 and 5 years [J].
Johnson, Andrea H. ;
Brennan, Jane C. ;
Maley, Alyssa ;
Levermore, Sandra B. ;
Turcotte, Justin J. ;
Petre, Benjamin M. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (02) :823-829