Radiation Exposure from Fluoroscopy during Hip Arthroscopy

被引:1
|
作者
Seijas, Roberto [1 ,2 ,3 ]
Catala, Jordi [4 ]
Cepas, Miguel Angel [5 ]
Sallent, Andrea [6 ]
Ares, Oscar [7 ]
Barastegui, David [1 ,2 ,8 ]
机构
[1] Hosp Quiron, Inst Cugat, Dept Orthoped Surg, Barcelona, Spain
[2] Garcia Cugat Fdn, Barcelona, Spain
[3] Univ Int Catalunya, Dept Anat, Barcelona, Spain
[4] Inst Guirado, Dept Radiol, Barcelona, Spain
[5] Hosp Quiron, Barcelona, Spain
[6] Hosp Valle De Hebron, Dept Orthoped, Barcelona, Spain
[7] Hosp Clin Barcelona, Dept Orthoped & Trauma, Barcelona, Spain
[8] Mutualitat Catalana Futbolistes, Barcelona, Spain
来源
SURGERY JOURNAL | 2019年 / 5卷 / 04期
关键词
femoroacetabular impingement; hip arthroscopy; fluoroscopy; radiation exposure; ESTABLISHMENT;
D O I
10.1055/s-0039-3400278
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective Hip arthroscopy for femoroacetabular impingement treatment is a procedure that is not exempted from complications. The most common complications are related to the arthroscopic portals and the traction system. The use of fluoroscopy helps in hip arthroscopy; however, the radiation exposure is a risk that has not yet been studied. Materials and Methods A retrospective study with 100 arthroscopies was performed. Surgical indication in all cases was femoroacetabular impingement. Surgical times and radiation exposure during the procedure had been recorded and reviewed for the present study. Results A mean of 138.20 cGy cm (2) radiation exposures was observed per patient and procedure for a mean time of radiation exposure of 0.36 minutes. These values are much lower than the values described as being at risk by the nuclear security commissions. Conclusions Radiation exposure in a hip arthroscopy due to femoroacetabular impingement is in margins well below the limits at risk for the patient.
引用
收藏
页码:E184 / E187
页数:4
相关论文
共 50 条
  • [1] Fluoroscopic Radiation Exposure During Hip Arthroscopy
    Gaymer, Caroline E.
    Achten, Juul
    Auckett, Roger
    Cooper, Lisa
    Griffin, Damian
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (05): : 870 - 873
  • [2] Intraoperative Radiation Exposure During Hip Arthroscopy
    Salvo, John P.
    Zarah, Jake
    Chaudhry, Zaira S.
    Poehling-Monaghan, Kirsten L.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2017, 5 (07):
  • [3] RADIATION EXPOSURE FROM FLUOROSCOPY DURING COLONOSCOPY
    OVERHOLT, BF
    MAHAN, G
    GASTROINTESTINAL ENDOSCOPY, 1980, 26 (02) : 73 - 73
  • [4] EXPOSURE TO RADIATION DURING FLUOROSCOPY
    不详
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1957, 163 (05): : 410 - 410
  • [5] EXPOSURE TO RADIATION DURING FLUOROSCOPY
    不详
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1957, 163 (12): : 1096 - 1096
  • [6] Radiation exposure from fluoroscopy during fixation of hip fracture and fracture of ankle: Effect of surgical experience
    Botchu, Rajesh
    Ravikumar, Kassetti
    INDIAN JOURNAL OF ORTHOPAEDICS, 2008, 42 (04) : 471 - 473
  • [7] The effect of surgical experience on the amount of radiation exposure from fluoroscopy during dynamic hip screw fixation
    Quah, C.
    Mehta, R.
    Shivji, F. S.
    Hassan, S.
    Chandrasenan, J.
    Moran, C. G.
    Forward, D. P.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2017, 99 (03) : 198 - 202
  • [8] Intraoperative radiation exposure in hip arthroscopy: a systematic review
    Shah, Ajay
    Nassri, Mohammed
    Kay, Jeffrey
    Simunovic, Nicole
    Mascarenhas, Vasco V.
    Andrade, Antonio J.
    Marin-Pena, Oliver R.
    Ayeni, Olufemi R.
    HIP INTERNATIONAL, 2020, 30 (03) : 267 - 275
  • [9] Fluoroscopy use and radiation exposure in the direct anterior hip approach
    Daines, Brian K.
    Yang, Charlie C.
    ANNALS OF JOINT, 2018, 3 (04):
  • [10] PATIENT AND PHYSICIAN RADIATION EXPOSURE DURING FLUOROSCOPY
    BENSON, JS