Glenoid baseplate screw fixation in reverse shoulder arthroplasty: does locking screw position and orientation matter?

被引:12
作者
Abdic, Sejla [1 ,2 ]
Lockhart, Jason [1 ,3 ]
Alnusif, Naser [1 ,4 ]
Johnson, James A. [1 ,2 ,3 ]
Athwal, George S. [1 ,2 ,4 ]
机构
[1] St Josephs Hosp, Rothl McFarlane Hand & Upper Limb Ctr, London, ON, Canada
[2] Western Univ, Dept Surg, London, ON, Canada
[3] Western Univ, Mech & Mat Engn, London, ON, Canada
[4] London Hlth Sci Ctr, Div Orthopaed Surg, London, ON, Canada
关键词
Reverse shoulder arthroplasty; baseplate fixation; micromotion; screw orientation; locking screw; compression screw; cuff tear arthropathy; COMPONENT; STRENGTH; DESIGN; FORCES; RANGE; PLATE;
D O I
10.1016/j.jse.2020.08.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The longevity of a reverse total shoulder arthroplasty prosthesis can be compromised by glenoid baseplate loosening. Circular baseplate designs can be secured with superoinferior (SI) locking screws and anteroposterior (AP) compression screws or vice versa (AP-locking and SI-compression screws). This biomechanical cadaveric study investigated screw position (locking screws SI vs. AP and compression screws AP and SI) and screw orientation (parallel vs. divergent) to determine quantitative differences in baseplate micromotion. Methods: Ten paired fresh-frozen cadaveric scapulae (n = 20) were implanted with a standard circular baseplate (empty set = 29 mm). The specimens were randomized into SI-locking or AP-locking screw configurations with the screw orientation directed either parallel or angled divergently at 15 degrees. This yielded a total of 4 groups for statistical comparison: SI-locking(parallel), SI-locking(divergent), AP-locking(parallel), and divergent, AP-locking(divergent), which were subjected to axial eccentric loading on the implanted baseplates, similar to the American Standard of Testing of Materials standard for shoulder joint arthroplasty. Results: In both static and cyclic testing, there were no statistically significant differences (P = .6) in micromotion between SI-locking (2.9 +/- 0.8 mu m) and AP-locking (3.5 +/- 1.5 mu m) configurations. In addition, there were no statistically significant differences (P - .2) in the divergent screw orientation group (2.0 +/- 0.7 mu m) vs. the parallel group (4.0 +/- 1.5 mu m). Conclusion: All configurations of screw position and screw orientation tested in a circular reverse baseplate have similar time-zero fix- ation in an intact glenoid bone model. In addition, the resultant micromotions for all configurations tested fell far below the 150 mu m threshold for bone ongrowth. (C) 2020 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:1207 / 1213
页数:7
相关论文
共 32 条
[1]  
Affonso Jesse, 2012, Instr Course Lect, V61, P157
[2]  
[Anonymous], 2015, Standard Test Method for Compressive Properties of Rigid Plastics, Vi, P1, DOI [10.1520/D0695-15.2, DOI 10.1520/D0695-15.2]
[3]   The reverse shoulder arthroplasty angle: a new measurement of glenoid inclination for reverse shoulder arthroplasty [J].
Boileau, Pascal ;
Gauci, Marc-Olivier ;
Wagner, Eric R. ;
Clowez, Gilles ;
Chaoui, Jean ;
Chelli, Mikael ;
Walch, Gilles .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (07) :1281-1290
[4]   Angled BIO-RSA (bony-increased offset-reverse shoulder arthroplasty): a solution for the management of glenoid bone loss and erosion [J].
Boileau, Pascal ;
Morin-Salvo, Nicolas ;
Gauci, Marc-Olivier ;
Seeto, Brian L. ;
Chalmers, Peter N. ;
Holzer, Nicolas ;
Walch, Gilles .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (12) :2133-2142
[5]   Factors affecting fixation of the glenoid component of a reverse total shoulder prothesis [J].
Chebli, Caroline ;
Huber, Philippe ;
Watling, Jonathan ;
Bertelsen, Alexander ;
Bicknell, Ryan T. ;
Matsen, Frederick, III .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (02) :323-327
[6]   Complications in Reverse Total Shoulder Arthroplasty [J].
Cheung, Emilie ;
Willis, Matthew ;
Walker, Matthew ;
Clark, Rachel ;
Frankle, Mark A. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2011, 19 (07) :439-449
[7]   Complication rates, dislocation, pain, and postoperative range of motion after reverse shoulder arthroplasty in patients with and without repair of the subscapularis [J].
Clark, Jason C. ;
Ritchie, Joseph ;
Song, Frederick S. ;
Kissenberth, Michael J. ;
Tolan, Stefan J. ;
Hart, Nathan D. ;
Hawkins, Richard J. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (01) :36-41
[8]   Reverse shoulder arthroplasty for instability arthropathy [J].
Clavert, Philippe ;
Kling, Agathe ;
Sirveaux, Francois ;
Favard, Luc ;
Mole, Daniel ;
Walch, Gilles ;
Boileau, Pascal .
INTERNATIONAL ORTHOPAEDICS, 2019, 43 (07) :1653-1658
[9]   Midterm clinical and radiologic results of reverse shoulder arthroplasty with an eccentric glenosphere [J].
Collotte, Philippe ;
Erickson, John ;
Vieira, Thais Dutra ;
Domos, Peter ;
Walch, Gilles .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (05) :976-981
[10]   Effects of Hybrid Plating With Locked and Nonlocked Screws on the Strength of Locked Plating Constructs in the Osteoporotic Diaphysis [J].
Doornink, Josef ;
Fitzpatrick, Dan C. ;
Boldhaus, Sebastian ;
Madey, Steven M. ;
Bottlang, Michael .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 69 (02) :411-417