Preliminary results for 2-D separation with high-performance thin-layer chromatography and pressurized planar electrochromatography

被引:25
作者
Chomicki, Adam [1 ]
Slazak, Piotr [1 ]
Dzido, Tadeusz H. [1 ]
机构
[1] Med Univ Lublin, Dept Phys Chem, PL-20081 Lublin, Poland
关键词
2-D Separation; High-performance thin-layer chromatography; Pressurized planar electrochromatography; MASS-SPECTROMETRY; MULTIDIMENSIONAL SEPARATION; LIQUID-CHROMATOGRAPHY; CLOSED-SYSTEM; APPARATUS; PEPTIDES; FLOW;
D O I
10.1002/elps.200900471
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Preliminary results of 2-D separation of test dye mixture using high-performance thin-layer chromatography (HPTLC) and pressurized planar electrochromatography (PPEC) arc demonstrated. The advantage of 2-D HPTLC/PPEC separation is based on different separation selectivities obtained in both HPTLC and PPEC systems. HPTLC RP18 W plates of 5 x 20 cm from Merck were used in the investigations. in the first dimension, a HPTLC process was performed using 5 cm length of the plate and in the second dimension PPEC separation was obtained applying plate of 20 cm length. PPEC process followed prewetting the chromatographic plate with sample zones on it, which were partly separated after first dimensional (HPTLC) separation. In the experiments, the modified version of PPEC device for 20 cm. long chromatographic plate and the reservoir for prewetting the adsorbent layer were applied.
引用
收藏
页码:3718 / 3725
页数:8
相关论文
共 19 条
[1]   Influence of the electrical double-layer on electroosmotic flow in capillary electrochromatography [J].
Cikalo, MG ;
Bartle, KD ;
Myers, P .
JOURNAL OF CHROMATOGRAPHY A, 1999, 836 (01) :35-51
[2]   Apparatus for pressurized planar electrochromatography in a completely closed system [J].
Dzido, Tadeusz H. ;
Plocharz, Pawel W. ;
Slazak, Piotr .
ANALYTICAL CHEMISTRY, 2006, 78 (13) :4713-4721
[3]   Adaptation of a horizontal DS chamber to planar electrochromatography in a closed system [J].
Dzido, TH ;
Mróz, J ;
Józwiak, GW .
JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2004, 17 (06) :404-410
[4]   Orthogonality of separation in two-dimensional liquid chromatography [J].
Gilar, M ;
Olivova, P ;
Daly, AE ;
Gebler, JC .
ANALYTICAL CHEMISTRY, 2005, 77 (19) :6426-6434
[5]   Multidimensional separation of peptides for effective proteomic analysis [J].
Issaq, HJ ;
Chan, KC ;
Janini, GM ;
Conrads, TP ;
Veenstra, TD .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 817 (01) :35-47
[6]  
Koesdjojo M.T., 2008, HDB CAPILLARY MICROC, V3rd, P183
[7]   New coupling of planar chromatography with direct analysis in real time mass spectrometry [J].
Morlock, Gertrud ;
Ueda, Yoshihisa .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1143 (1-2) :243-251
[8]   Use of multidimensional separation protocols for the purification of trace components in complex biological samples for proteomics analysis [J].
Nice, E. C. ;
Rothacker, J. ;
Weinstock, J. ;
Lim, L. ;
Catimel, B. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1168 (1-2) :190-210
[9]  
Niessen WMA, 2006, CHROMATOGR SCI SER, V97, P3
[10]   Results with an apparatus for pressurized planar ectrochromatography [J].
Novotny, AL ;
Nurok, D ;
Replogle, RW ;
Hawkins, GL ;
Santini, RE .
ANALYTICAL CHEMISTRY, 2006, 78 (08) :2823-2831