Microfluidic Preparative Free-Flow Isoelectric Focusing: System Optimization for Protein Complex Separation

被引:64
作者
Wen, Jian [2 ]
Wilker, Erik W. [1 ]
Yaffe, Michael B. [1 ]
Jensen, Klavs F. [2 ]
机构
[1] MIT, Dept Biol & Biol Engn, Koch Inst Integrat Canc Res, Cambridge, MA 02139 USA
[2] MIT, Dept Chem Engn, Koch Inst Integrat Canc Res, Cambridge, MA 02139 USA
关键词
CAPILLARY-ELECTROPHORESIS; SAMPLE PREFRACTIONATION; ZONE-ELECTROPHORESIS; GLOBAL ANALYSIS; DEVICE; LIVER; RESOLUTION; MICROCHIP; MEMBRANES; PEPTIDES;
D O I
10.1021/ac902157e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Isoelectric focusing (IEF) is the first step for two-dimensional (2D) gel electrophoresis and plays an important role in sample purification for proteomics. However, biases in protein size and pI resolution, as well as limitations in sample volume, gel capacity, sample loss, and experimental time, remain challenges. In order to address some of the limitations of traditional IEF, we present a microfluidic free flow IEF (FF-IEF) device for continuous protein separation into 24 fractions. The device reproducibly establishes a nearly linear pH gradient from 4 to 10. Optimized dynamic coatings of 4% poly(vinyl alcohol) (PVA) minimize peak broadening by transverse electrokinetic flows. Even though the device operates at high electric fields (up to 370 V/cm), efficient cooling maintains solution temperature inside the separation channel controllably in the range 2-25 degrees C. Protein samples with a dynamic concentration range from mu g/mL to mg/mL can be loaded into the microdevice at a flow rate of 1 mL/h and residence time of similar to 12 min. By using a protein complex of nine proteins and 13 isoforms, we demonstrate improved separation with the FF-IEF system over traditional 2D get electrophoresis. Device-to-device reproducibility is also illustrated through the efficient depletion of the albumin and hemoglobin assays. Post-device sample concentrations result in a 10-20-fold increase, which allow for isolation and detection of low abundance proteins. The separation of specific proteins from a whole cell lysate is demonstrated as an example. The microdevice has the further benefits of retaining high molecular weight proteins, providing higher yield of protein that has a broader range in pI, and reducing experimental time compared to conventional IEF IGP gel strip approaches.
引用
收藏
页码:1253 / 1260
页数:8
相关论文
共 38 条
  • [1] Cascaded free-flow isoelectric focusing for improved focusing speed and resolution
    Albrecht, Jacob W.
    El-Ali, Jamil
    Jensen, Klavs F.
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (24) : 9364 - 9371
  • [2] Micro free-flow IEF enhanced by active cooling and functionalized gels
    Albrecht, Jacob W.
    Jensen, Klavs F.
    [J]. ELECTROPHORESIS, 2006, 27 (24) : 4960 - 4969
  • [3] Free-flow electrophoresis for fractionation of Arabidopsis thaliana membranes
    Bardy, N
    Carrasco, A
    Galaud, JP
    Pont-Lezica, R
    Canut, H
    [J]. ELECTROPHORESIS, 1998, 19 (07) : 1145 - 1153
  • [4] Recycling isoelectric focusing and isotachophoresis
    Bier, M
    [J]. ELECTROPHORESIS, 1998, 19 (07) : 1057 - 1063
  • [5] FREE-FLOW ISOELECTRIC-FOCUSING OF HUMAN CELLULAR LYSATES AS SAMPLE PREPARATION FOR PROTEIN-ANALYSIS
    BURGGRAF, D
    WEBER, G
    LOTTSPEICH, F
    [J]. ELECTROPHORESIS, 1995, 16 (06) : 1010 - 1015
  • [6] Cabrera CR, 2001, ELECTROPHORESIS, V22, P355, DOI 10.1002/1522-2683(200101)22:2<355::AID-ELPS355>3.0.CO
  • [7] 2-C
  • [8] Isoelectric focusing in a poly(dimethylsiloxane) microfluidic chip
    Cui, HC
    Horiuchi, K
    Dutta, P
    Ivory, CF
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (05) : 1303 - 1309
  • [9] Effects of separation length and voltage on isolectric focusing in a plastic microfluidic device
    Das, Champak
    Fan, Z. Hugh
    [J]. ELECTROPHORESIS, 2006, 27 (18) : 3619 - 3626
  • [10] Free-flow electrophoresis on an anodic bonded glass microchip
    Fonslow, BR
    Bowser, MT
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (17) : 5706 - 5710