Investigation of the presence of Legionella pneumophila in water samples from Erzurum and surrounding provinces in Turkey

被引:2
|
作者
Yilmaz, Ahmet [1 ]
Orhan, Figen [2 ]
机构
[1] Erzurum Prov Directorate Hlth, Erzurum, Turkey
[2] Ataturk Univ, Vocat Sch Hlth Serv, Dept Med Lab Tech, Erzurum, Turkey
关键词
Legionella pneumophila; hospital; hotel; water samples; HOSPITAL WATER; HOT-WATER; PATHOGENS; RISK;
D O I
10.26444/aaem/135052
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Introduction and objective. Legionnaires' disease, which is a waterborne disease leading to pneumonia that can result in death, is one of the major health issues today. The study aims to carry out a three-year retrospective review of routine Legionella follow-up analyses in various samples taken mostly from hospitals in the province of Erzurum and nearby provinces, and to discover a the frequency of isolation of the agent and serogroups from each kind of media. Materials and method. The study included a total of 2,025 water samples taken from hospitals, hotels, Turkish baths and shopping malls in Erzurum, and 13 nearby cities between 2016 and 2018. Samples were filtered by 0.45 mu m-diameter membrane filter paper in the Public Health Laboratory of Erzurum and examined for L. pneumophila using culture method, according to the criteria set out in ISO 11731-2. Results. The presence of L. pneumophila was found in 65 of the 2,025 water samples taken in hospitals, and in none of 40 samples taken in hotels, Turkish baths and shopping malls. L. pneumophila serogroup 2-14 was detected in 46 (70.8%) of 65 samples found positive, whereas L. pneumophila serogroup 1 was detected in 18 (27.7%). Furthermore, both the L. pneumophila serogroup 2-14 and L. pneumophila serogroup 1 were detected simultaneously in one example (1.5%). The first three samples indicate that the highest positivity rates were in hot water taps (11.6%), hot water tanks (6.1%) and shower heads (4.8%). Conclusions. The Prevalence rat of L. pneumophila was found to be quite low compared to other studies conducted in the western regions of Turkey. Legionella positivity was found to be higher in the hot water systems of hospitals and related points, compared to the other sample points.
引用
收藏
页码:255 / 259
页数:5
相关论文
共 50 条
  • [1] Exploring the Legionella pneumophila positivity rate in hotel water samples from Antalya, Turkey
    Ozen, Nevgun Sepin
    Ataman, Senay Tuglu
    Emek, Mestan
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2017, 24 (13) : 12238 - 12242
  • [2] New system for the detection of Legionella pneumophila in water samples
    Parraga-Nino, Noemi
    Quero, Sara
    Ventos-Alfonso, Alba
    Uria, Naroa
    Castillo-Fernandez, Oscar
    Ezenarro, Josune J.
    Munoz, Francesc-Xavier
    Garcia-Nunez, Marian
    Sabria, Miguel
    TALANTA, 2018, 189 : 324 - 331
  • [3] SPR based immunosensor for detection of Legionella pneumophila in water samples
    Enrico, De Lorenzis
    Manera, Maria G.
    Montagna, Giovanni
    Cimaglia, Fabio
    Chiesa, Maurizio
    Poltronieri, Palmiro
    Santino, Angelo
    Rella, Roberto
    OPTICS COMMUNICATIONS, 2013, 294 : 420 - 426
  • [4] Design of an optical nanobiosensor for detection of Legionella pneumophila in water samples
    Karimiravesh, Raheleh
    Mobarez, Ashraf Mohabati
    Behmanesh, Mehrdad
    Nikkhah, Maryam
    Abadi, Amin Talebi Bezmin
    Esmaeilli, Saber
    IRANIAN JOURNAL OF MICROBIOLOGY, 2022, 14 (06) : 802 - 812
  • [5] Comparison of two culture methods for the enumeration of Legionella pneumophila from potable water samples
    Boczek, Laura A.
    Tang, Min
    Formal, Casey
    Lytle, Darren
    Ryu, Hodon
    JOURNAL OF WATER AND HEALTH, 2021, 19 (03) : 468 - 477
  • [6] Evaluation of a Legionella urinary antigen enzyme immunoassay for rapid Detection of Legionella pneumophila in water samples
    Blanco, S.
    Prat, C.
    Sanchez, M. D.
    Ferrer, D.
    Pellicer, T.
    Haba, L.
    Latorre, I.
    Vilaplana, C.
    Ausina, V.
    Dominguez, J.
    INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2008, 211 (1-2) : 168 - 171
  • [7] Detection and quantification of Legionella pneumophila in water samples using competitive PCR
    Declerck, Priscilla
    Behets, Jonas
    Lammertyn, Elke
    Lebeau, Ilya
    Anne, Jozef
    Ollevier, Frans
    CANADIAN JOURNAL OF MICROBIOLOGY, 2006, 52 (06) : 584 - 590
  • [8] Investigation of Legionella pneumophila and free living amoebas in the domestic hot water systems in Istanbul
    Burak, Dilara Meryem
    Zeybek, Zuhal
    TURKISH JOURNAL OF BIOLOGY, 2011, 35 (06) : 679 - 685
  • [9] PRESENCE OF BACTERIA Legionella pneumophila IN WARM TAP WATER IN RELATION TO ECOLOGICAL FACTORS
    Rakic, Anita
    Peric, Jelena
    Stambuk-Giljanovic, Nives
    HRVATSKE VODE, 2013, 21 (83) : 1 - 6
  • [10] Evaluation of a most probable number method for the enumeration of Legionella pneumophila from potable and related water samples
    Sartory, D. P.
    Spies, K.
    Lange, B.
    Schneider, S.
    Langer, B.
    LETTERS IN APPLIED MICROBIOLOGY, 2017, 64 (04) : 271 - 275