Laboratory versus Field Calibration of Capacitance Probes

被引:39
作者
Luis Gabriel, Jose [1 ]
Lizaso, Jon I. [1 ]
Quemada, Miguel [1 ]
机构
[1] Univ Politecn Madrid, Dep Prod Vegetal, E-28040 Madrid, Spain
关键词
SOIL-MOISTURE MEASUREMENT; WATER-CONTENT; IRRIGATION; TEMPERATURE; MANAGEMENT; DYNAMICS; DRAINAGE; SENSORS;
D O I
10.2136/sssaj2009.0157
中图分类号
S15 [土壤学];
学科分类号
0903 ; 090301 ;
摘要
Capacitance probes (CP) based on responses to electromagnetic properties in soil are widely used for monitoring soil volumetric water content (theta(v)), but proper calibration is necessary to obtain reliable results. The objectives of this study were to: (i) compare errors in evaluating theta(v) when using soil-spccific equations as opposed to the manufacturer's default equation; (ii) compare the CP calibration equations obtained in the laboratory and in the field; and (iii) evaluate the accuracy of CP under field conditions using soil-specific equations as opposed to the manufacturer's default equation. Laboratory and field calibrations were conducted by fitting statistical relationships between readings from CP and theta(v) measured from soil cores. The accuracies of the obtained calibration equations were evaluated under field conditions during, two irrigation cycles. In both calibration studies, the manufacturer's default equation consistently overcalculated theta(v) (RMSE > 0.044 m(3) m(-3)), whereas custom CP calibration equations provided accurate theta(v) determinations (RMSE < 0.028 m(3) m(-3)). Even when theta(v) was overestimated, the manufacturer's default equation was able to reproduce theta(v) dynamics during irrigation. Therefore, if users are interested in relative differences in theta(v), they may use the manufacturer's default equation. If absolute values are needed, however, soil-specific calibration is required. The accuracy of CP in monitoring theta(v) under field conditions was slightly better using the laboratory calibration equation (RMSE = 0.019 m(3) m(-3)) rather than the field calibration equation (RMSE = 0.023 m(3) m(-3)). The use of a laboratory calibration is recommended given that it is easily reproducible, facilitates work planning, and minimizes uncertainties.
引用
收藏
页码:593 / 601
页数:9
相关论文
共 27 条
[1]  
Allen R.G., 1998, FAO Irrigation and Drainage Paper 56
[2]   Drainage and nitrate leaching in a crop rotation under different N-fertilizer strategies: application of capacitance probes [J].
Arregui, L. M. ;
Quemada, M. .
PLANT AND SOIL, 2006, 288 (1-2) :57-69
[3]   Soil material, temperature, and salinity effects on calibration of multisensor capacitance probes [J].
Baumhardt, RL ;
Lascano, RJ ;
Evett, SR .
SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2000, 64 (06) :1940-1946
[4]   The dielectric behaviour of clay soils and its application to time domain reflectometry [J].
Bridge, BJ ;
Sabburg, J ;
Habash, KO ;
Ball, JAR ;
Hancock, NH .
AUSTRALIAN JOURNAL OF SOIL RESEARCH, 1996, 34 (06) :825-835
[5]   Soil moisture monitoring at the field scale using automatic capacitance probes [J].
Chanzy, A ;
Chadoeuf, J ;
Gaudu, JC ;
Mohrath, D ;
Richard, G ;
Bruckler, L .
EUROPEAN JOURNAL OF SOIL SCIENCE, 1998, 49 (04) :637-648
[6]   Soil profile water content determination: Sensor accuracy, axial response, calibration, temperature dependence, and precision [J].
Evett, Steven R. ;
Tolk, Judy A. ;
Howell, Terry A. .
VADOSE ZONE JOURNAL, 2006, 5 (03) :894-907
[7]   Advances in crop water management using capacitive water sensors [J].
Fares, A. ;
Polyakov, V. .
ADVANCES IN AGRONOMY, VOL 90, 2006, 90 :43-77
[8]  
Fares A, 2004, VADOSE ZONE J, V3, P1390
[9]   Evaluation of capacitance probes for optimal irrigation of citrus through soil moisture monitoring in an entisol profile [J].
Fares, A ;
Alva, AK .
IRRIGATION SCIENCE, 2000, 19 (02) :57-64
[10]   Real-time soil water monitoring for optimum water management [J].
Fares, Ali ;
Hamdhani, H. ;
Polyakov, Viktor ;
Dogan, A. ;
Valenzuela, Hector .
JOURNAL OF THE AMERICAN WATER RESOURCES ASSOCIATION, 2006, 42 (06) :1527-1535