Study of the relative responsiveness of five sensibility tests for assessment of recovery after median nerve injury and repair

被引:55
作者
Jerosch-Herold, C [1 ]
机构
[1] Univ E Anglia, Sch Occupat Therapy & Physiotherapy, Norwich NR4 7TJ, Norfolk, England
关键词
D O I
10.1016/S0266-7381(03)00017-2/jhsb.2003.0917
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A longitudinal dynamic cohort study was conducted on patients with median nerve injuries to evaluate the relative responsiveness of five sensibility tests: touch threshold using the WEST (monofilaments), static two-point discrimination, locognosia, a pick-up test and an object recognition test. Repeated assessments were performed starting at 6 months after surgery. In order to compare the relative responsiveness of each test, effect size and the standard response mean were calculated for sensibility changes occurring between 6 and 18 months after repair. Large effect sizes (> 0.8) and standard response means (> 0.8) were obtained for the WEST, locognosia, pick-up and object recognition tests. Two-point discrimination was hardly measurable at any time point and exhibited strong flooring effects. Further analysis of all time points was undertaken to assess the strength of the monotonic relationship between test scores and time elapsed since surgery. Comparison of monotonicity between the five tests indicated that the WEST performed best, whereas two-point discrimination performed worst. Theses results suggest that the monofilament test (WEST), locognosia test, Moberg pick-up test and tactile gnosis test capture sensibility changes over time well and should be considered for inclusion in the outcome assessment of patients with median nerve injury.
引用
收藏
页码:255 / 260
页数:6
相关论文
共 29 条
[1]  
ALQUATTAN M, 1995, CANADIAN J PLASTIC S, V3, P51
[2]   A taxonomy for responsiveness [J].
Beaton, DE ;
Bombardier, C ;
Katz, JN ;
Wright, JG .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2001, 54 (12) :1204-1217
[3]  
Bell-Krotoski J, 1993, J Hand Ther, V6, P114
[4]  
Bell-Krotoski J A, 1997, J Hand Ther, V10, P297
[5]   THE REPEATABILITY OF TESTING WITH SEMMES-WEINSTEIN MONOFILAMENTS [J].
BELLKROTOSKI, J ;
TOMANCIK, E .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1987, 12A (01) :155-161
[6]  
BIRCH R, 1996, J BONE JOINT SURG BR, V68, P3
[7]  
Cohen J, 1977, STAT POWER BEHAV SCI
[8]  
DELLON AL, 1983, J HAND SURG-AM, V8, P865
[9]  
Fisher L.D., 1993, BIOSTATISTICS METHOD
[10]   MEASURING CHANGE OVER TIME - ASSESSING THE USEFULNESS OF EVALUATIVE INSTRUMENTS [J].
GUYATT, G ;
WALTER, S ;
NORMAN, G .
JOURNAL OF CHRONIC DISEASES, 1987, 40 (02) :171-178