EFFECTS OF TWO DIFFERENT ANESTHETIC PROTOCOLS ON 64-MDCT CORONARY ANGIOGRAPHY IN DOGS

被引:10
作者
Drees, Randi [1 ]
Johnson, Rebecca A. [1 ]
Pinkerton, Marie [2 ]
Del Rio, Alejandro Munoz [3 ,4 ]
Saunders, Jimmy H. [5 ]
Francois, Christopher J. [3 ,4 ]
机构
[1] UW Madison VMTH, Dept Surg Sci, Madison, WI 53706 USA
[2] UW Madison VMTH, Dept Pathobiol Sci, Madison, WI 53706 USA
[3] UW Madison, Dept Med Phys, Madison, WI 53792 USA
[4] UW Madison, Dept Radiol, Sch Med & Publ Hlth, Madison, WI 53792 USA
[5] UGent, Fac Vet Med, B-9820 Merelbeke, Belgium
关键词
computed tomography; dexmedetomidine; fentanyl; heart; midazolam; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; MINIMUM ALVEOLAR CONCENTRATION; CONTINUOUS RATE INFUSION; CONSTANT RATE INFUSION; ISOFLURANE ANESTHESIA; DIAGNOSTIC-ACCURACY; LIDOCAINE-KETAMINE; PULMONIC STENOSIS; IMAGE QUALITY; HEART-RATE;
D O I
10.1111/vru.12185
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Heart rate is a major factor influencing diagnostic image quality in computed tomographic coronary artery angiography (MDCT-CA), with an ideal heart rate of 60-65 beats/min in humans. The purpose of this prospective study was to compare effects of two different clinically applicable anesthetic protocols on cardiovascular parameters and 64-MDCT-CA quality in 10 healthy dogs. Scan protocols and bolus volumes were standardized. Image evaluations were performed in random order by a board-certified veterinary radiologist who was unaware of anesthetic protocols used. Heart rate during image acquisition did not differ between protocols (P = 1), with 80.6 +/- 7.5 bpm for protocol A and 79.2 +/- 14.2 bpm for protocol B. Mean blood pressure was significantly higher (P > 0.05) using protocol B (protocol A 62.9 +/- 9.1 vs. protocol B 72.4 +/- 15.9 mmHg). The R-R intervals allowing for best depiction of individual coronary artery segments were found in the end diastolic period and varied between the 70% and 95% interval. Diagnostic quality was rated excellent, good, and moderate in the majority of the segments evaluated, with higher scores given for more proximal segments and lower for more distal segments, respectively. Blur was the most commonly observed artifact and mainly affected the distal segments. No significant differences were identified between the two protocols for optimal reconstruction interval, diagnostic quality and measured length individual segments, or proximal diameter of the coronary arteries (P = 1). Findings indicated that, when used with a standardized bolus volume, both of these anesthetic protocols yielded diagnostic quality coronary 64-MDCT-CA exams in healthy dogs. (C) 2014 American College of Veterinary Radiology.
引用
收藏
页码:46 / 54
页数:9
相关论文
共 39 条
[1]   Reduction of the minimum alveolar concentration of isoflurane in dogs using a constant rate of infusion of lidocaine-ketamine in combination with either morphine or fentanyl [J].
Aguado, Delia ;
Benito, Javier ;
Gomez de Segura, Ignacio A. .
VETERINARY JOURNAL, 2011, 189 (01) :63-66
[2]  
[Anonymous], 2012, R LANG ENV STAT COMP
[3]  
Austen W G, 1975, Circulation, V51, P5
[4]   Dexmedetomidine Alters the Cardiovascular Response During Infra-Renal Aortic Cross-Clamping in Sevoflurane-Anesthetized Dogs [J].
Braz, Leandro G. ;
Cerqueira Braz, Jose R. ;
Machado Castiglia, Yara M. ;
Galvaeo Vianna, Pedro T. ;
Vane, Luiz A. ;
Pinheiro Modolo, Norma S. ;
do Nascimento, Paulo, Jr. ;
da Silva, Andre L. ;
Kinsky, Michael P. .
JOURNAL OF INVESTIGATIVE SURGERY, 2008, 21 (06) :360-368
[5]  
BUCHANAN JW, 1990, J AM VET MED ASSOC, V196, P115
[6]  
Buchanan JW, 2001, J VET INTERN MED, V15, P101, DOI 10.1892/0891-6640(2001)015<0101:POSRCA>2.3.CO
[7]  
2
[8]   Effects of nitroglycerin on the diagnostic accuracy of electrocardiogram-gated coronary computed tomography angiography [J].
Chun, Eun Ju ;
Lee, Whal ;
Choi, Young Hoon ;
Koo, Bon-Kwon ;
Choi, Sang Il ;
Jae, Hwan Jun ;
Kim, Hyo-Cheol ;
So, Young Ho ;
Chung, Jin Wook ;
Park, Jae Hyung .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (01) :86-92
[9]   Clinical Application of CT Coronary Angiography: State of the Art [J].
de Graaf, F. R. ;
Schuijf, J. D. ;
Delgado, V. ;
van Velzen, J. E. ;
Kroft, L. J. ;
de Roos, A. ;
Jukema, J. W. ;
van der Wall, E. E. ;
Bax, J. J. .
HEART LUNG AND CIRCULATION, 2010, 19 (03) :107-116
[10]   Evaluation of Contraindications and Efficacy of Oral Beta Blockade Before Computed Tomographic Coronary Angiography [J].
de Graaf, Fleur R. ;
Schuijf, Joanne D. ;
van Velzen, Joella E. ;
Kroft, Lucia J. ;
de Roos, Albert ;
Sieders, Allard ;
Jukema, J. Wouter ;
Schalij, Martin J. ;
van der Wall, Ernst E. ;
Bax, Jeroen J. .
AMERICAN JOURNAL OF CARDIOLOGY, 2010, 105 (06) :767-772