RMSSD Is More Sensitive to Artifacts Than Frequency-Domain Parameters: Implication in Athletes? Monitoring

被引:31
作者
Bourdillon, Nicolas [1 ,2 ]
Yazdani, Sasan [2 ]
Vesin, Jean-Marc [3 ]
Schmitt, Laurent [4 ]
Millet, Gregoire P. [1 ]
机构
[1] Univ Lausanne, Inst Sport Sci, CH-1015 Lausanne, Switzerland
[2] Be care SA, Renens, Switzerland
[3] Ecole Polytech Fed, EPFL, Appl Signal Proc Grp, ASPG, CH-1015 Lausanne, Switzerland
[4] Natl Ctr Nordic Ski Res & Performance, Premanon, France
关键词
Artifact; frequency-domain; heart rate variability; noise; time-domain; HEART-RATE-VARIABILITY; ECTOPIC BEATS; TIME;
D O I
10.52082/jssm.2022.260
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Easy-to-use and accurate heart rate variability (HRV) assessments are essential in athletes??? follow-up, but artifacts may lead to erroneous analysis. Artifact detection and correction are the purpose of extensive literature and implemented in dedicated analysis programs. However, the effects of number and/or magnitude of artifacts on various time-or frequency-domain parameters remain unclear. The purpose of this study was to assess the effects of artifacts on HRV parameters. Root mean square of the successive differences (RMSSD), standard deviation of the normal to normal inter beat intervals (SDNN), power in the low-(LF) and high-frequency band (HF) were computed from two 4-min RR recordings in 178 participants in both supine and standing positions, respectively. RRs were modified by (1) randomly adding or subtracting 10, 30, 50 or 100 ms to the successive RRs; (2) a single artifact was manually inserted; (3) artifacts were automatically corrected from signal naturally containing artifacts. Finally, RR recordings were analyzed before and after automatic detection-correction of artifacts. Modifying each RR by 10, 30, 50 and 100 ms randomly did not significantly change HRV parameters (range-6%, +6%, supine). In contrast, by adding a single artifact, RMSSD increased by 413% and 269%, SDNN by 54% and 47% in supine and standing positions, respectively. LF and HF changed only between-3% and +8% (supine and standing) in the artifact condition. When more than 0.9% of the signal contained artifacts, RMSSD was significantly biased, whilst when more than 1.4% of the signal contained artifacts LF and HF were significantly biased. RMSSD and SDNN were more sensitive to a single artifact than LF and HF. This indicates that, when using RMSSD only, a single artifact may induce erroneous interpretation of HRV. Therefore, we recommend using both time-and frequency-domain parameters to minimize the errors in the diagnoses of health status or fatigue in athletes.
引用
收藏
页码:260 / 266
页数:7
相关论文
共 26 条
[1]   The ClassA Framework: HRV Based Assessment of SNS and PNS Dynamics Without LF-HF Controversies [J].
Adjei, Tricia ;
von Rosenberg, Wilhelm ;
Nakamura, Takashi ;
Chanwimalueang, Theerasak ;
Mandic, Danilo P. .
FRONTIERS IN PHYSIOLOGY, 2019, 10
[2]   AN APPROACH TO ARTIFACT IDENTIFICATION - APPLICATION TO HEART PERIOD DATA [J].
BERNTSON, GG ;
QUIGLEY, KS ;
JANG, JF ;
BOYSEN, ST .
PSYCHOPHYSIOLOGY, 1990, 27 (05) :586-598
[3]   ECG artifacts and heart period variability: Don't miss a beat! [J].
Berntson, GG ;
Stowell, JR .
PSYCHOPHYSIOLOGY, 1998, 35 (01) :127-132
[4]   Minimal Window Duration for Accurate HRV Recording in Athletes [J].
Bourdillon, Nicolas ;
Schmitt, Laurent ;
Yazdani, Sasan ;
Vesin, Jean-Marc ;
Millet, Gregoire P. .
FRONTIERS IN NEUROSCIENCE, 2017, 11
[5]  
Camm AJ, 1996, CIRCULATION, V93, P1043
[6]   Endurance training guided individually by daily heart rate variability measurements [J].
Kiviniemi, Antti M. ;
Hautala, Arto J. ;
Kinnunen, Hannu ;
Tulppo, Mikko P. .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2007, 101 (06) :743-751
[7]   Evidence of Parasympathetic Hyperactivity in Functionally Overreached Athletes [J].
Le Meur, Yann ;
Pichon, Aurelien ;
Schaal, Karine ;
Schmitt, Laurent ;
Louis, Julien ;
Gueneron, Jacques ;
Vidal, Pierre Paul ;
Hausswirth, Christophe .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (11) :2061-2071
[8]   A robust algorithm for heart rate variability time series artefact correction using novel beat classification [J].
Lipponen J.A. ;
Tarvainen M.P. .
Journal of Medical Engineering and Technology, 2019, 43 (03) :173-181
[9]  
Manis G., 2005, P 1 INT WORKSH BIOS, P161
[10]   Respiratory sinus arrhythmia - testing the method of choice for evaluation of cardiovagal regulation [J].
Mestanik, Michal ;
Mestanikova, Andrea ;
Langer, Peter ;
Grendar, Marian ;
Jurko, Alexander, Jr. ;
Sekaninova, Nikola ;
Visnovcova, Nadezda ;
Tonhajzerova, Ingrid .
RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2019, 259 :86-92