Analysis of the Mechanical Behavior and Effect of Cyclic Fatigue on the Implant-Abutment Interface

被引:0
作者
German Sandoval, Ramon [1 ]
Ortiz Magdaleno, Marine [1 ]
Sanchez Robles, Paula [1 ]
Zavala Alonso, Norma [2 ]
Romo Ramirez, Gabriel Fernando [1 ]
机构
[1] Autonomous Univ San Luis Potosi, Fac Stomatol, Aesthet Cosmet Restorat & Implantol Dent, San Luis Potosi, San Luis Potosi, Mexico
[2] Autonomous Univ San Luis Potosi, Fac Stomatol, Dept Dent Sci Adv Educ, San Luis Potosi, San Luis Potosi, Mexico
关键词
Abutment; Implant; Microgap; Cyclic fatigue; Compressive stress; FINITE-ELEMENT-ANALYSIS; STRESS-DISTRIBUTION; MARGINAL FIT; OSSEOINTEGRATED IMPLANTS; ZIRCONIA ABUTMENTS; VERTICAL MISFIT; MUCOSAL BARRIER; TITANIUM; MICROLEAKAGE; CONNECTIONS;
D O I
10.15517/IJDS.2021.45011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The seal of the interface formed at the implant-abutment connection is essential for the long-term success of the implant-supported restoration. The aim of this study was to analyze the mechanical behavior and the effect of cyclic fatigue before and after in the marginal fit of implant-abutment according to the manufacturing technique of the abutment. Materials and methods: Machined titanium abutments (DENTIS), cast abutments with Nickel-Chromium alloy (VeraBond II), and manufacturing custom milled Zirconia abutments (Zirkonzahn) were evaluated. The implant-abutment assemblies were subjected to cyclic loads of 133 N at a frequency of 19.1 Hz for 200,000 cycles. The microgap was measured using Scanning Electronic Microscope and the distribution of compressive stress by the three-dimensional Finite Element (FE) method. Results: The microgap measurement values of the machined abutments were 1.62 mu m and 1.92 mu m, cast abutments were 14.14 mu m, and 28.44 mu m, and the milled abutments were 14.18 mu m and 20.15 mu m before and after cyclic fatigue, respectively. Only the cast abutments and the machined abutments showed a statistically significant difference before and after cyclic fatigue (p <= 0.05). The FE analysis showed that the critical areas of compressive stress were located at the implant-abutment connection, increasing in the cast abutments and decreasing in the milled and the machined abutments. Conclusion: Cyclic fatigue exerts an effect on the dimensions of the microgap at the implant-abutment interface before and after loading; this microgap depends of the type of abutment material and the manufacturing technique.
引用
收藏
页码:104 / 114
页数:11
相关论文
共 40 条
[1]   The mucosal barrier following abutment dis/reconnection - An experimental study in dogs [J].
Abrahamsson, I ;
Berglundh, T ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1997, 24 (08) :568-572
[2]  
[Anonymous], 1996, ISO 5832 31996 E, P42
[3]   PHOTOELASTIC STRESS ANALYSIS OF EXTERNAL VERSUS INTERNAL IMPLANT-ABUTMENT CONNECTIONS [J].
Asvanund, Pattapon ;
Morgano, Steven M. .
JOURNAL OF PROSTHETIC DENTISTRY, 2011, 106 (04) :266-271
[4]   Stress distribution in fixed-partial prosthesis and peri-implant bone tissue with different framework materials and vertical misfit levels: a three-dimensional finite element analysis [J].
Bacchi, Atais ;
Consani, Rafael L. X. ;
Mesquita, Marcelo F. ;
dos Santos, Mateus B. F. .
JOURNAL OF ORAL SCIENCE, 2013, 55 (03) :239-244
[5]   THE INFLUENCE OF IMPLANT DIAMETER AND LENGTH ON STRESS DISTRIBUTION OF OSSEOINTEGRATED IMPLANTS RELATED TO CRESTAL BONE GEOMETRY: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS [J].
Baggi, Luigi ;
Cappelloni, Ilaria ;
Di Girolamo, Michele ;
Maceri, Franco ;
Vairo, Giuseppe .
JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (06) :422-431
[6]  
Baixe S, 2010, INT J ORAL MAX IMPL, V25, P455
[7]   Design of dynamic test equipment for the testing of dental implants [J].
Barry, M ;
Kennedy, D ;
Keating, K ;
Schauperl, Z .
MATERIALS & DESIGN, 2005, 26 (03) :209-216
[8]  
Bidez M W, 1992, J Oral Implantol, V18, P264
[9]  
Binon PP, 1996, INT J PROSTHODONT, V9, P511
[10]   Fatigue induced changes in conical implant-abutment connections [J].
Blum, Kai ;
Wiest, Wolfram ;
Fella, Christian ;
Balles, Andreas ;
Dittmann, Jonas ;
Rack, Alexander ;
Maier, Dominik ;
Thomann, Ralf ;
Spies, Benedikt Christopher ;
Kohal, Ralf Joachim ;
Zabler, Simon ;
Nelson, Katja .
DENTAL MATERIALS, 2015, 31 (11) :1415-1426