Uncertainty analysis and field implementation of a fault detection method for residential HVAC systems

被引:7
作者
Rogers, Austin [1 ]
Guo, Fangzhou [1 ]
Rasmussen, Bryan [1 ]
机构
[1] Texas A&M Univ, Dept Mech Engn, College Stn, TX 77843 USA
关键词
DIAGNOSIS;
D O I
10.1080/23744731.2019.1676093
中图分类号
O414.1 [热力学];
学科分类号
摘要
The vast majority of fault detection and diagnosis (FDD) methods for air conditioning systems are developed for packaged commercial systems. This paper presents a method for obtaining key operating parameters for air conditioning systems (airflow rate, cooling capacity, system efficiency, and refrigerant mass flow) in a way that is well-suited for the residential sector. The method relies on an air-side capacity estimate and will be compared and contrasted with a more traditional method that relies on a refrigerant-side capacity estimate. These methods are compared in terms of their sensitivity to input parameters, their uncertainty in the outputs, and their sensor requirements. The proposed air-side sensing method requires fewer sensors and has a significant advantage for residential split systems because it requires no outdoor unit sensors. The air-side sensing method is then successfully implemented on a field operating residential system. The experimental results show that the proposed method is sensitive to manually introduced airflow faults.
引用
收藏
页码:320 / 333
页数:14
相关论文
共 28 条
  • [21] Decoupling features and virtual sensors for diagnosis of faults in vapor compression air conditioners
    Li, Haorong
    Braun, James E.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2007, 30 (03) : 546 - 564
  • [22] Virtual Refrigerant Pressure Sensors for Use in Monitoring and Fault Diagnosis of Vapor-Compression Equipment
    Li, Haorong
    Braun, James E.
    [J]. HVAC&R RESEARCH, 2009, 15 (03): : 597 - 616
  • [23] A critical review of fault modeling of HVAC systems in buildings
    Li, Yanfei
    O'Neill, Zheng
    [J]. BUILDING SIMULATION, 2018, 11 (05) : 953 - 975
  • [24] NEME C, 1999, A992 AM COUNC AN EFF
  • [25] Rossi T.M., 1997, HVACR Research, V3, P19
  • [26] Yu D, 2011, J THERM SCI ENG APPL, V3, P1, DOI DOI 10.1115/1.4003702
  • [27] A virtual supply airflow rate meter for rooftop air-conditioning units
    Yu, Daihong
    Li, Haorong
    Yang, Mo
    [J]. BUILDING AND ENVIRONMENT, 2011, 46 (06) : 1292 - 1302
  • [28] Fault diagnosis for heat pumps with parameter identification and clustering
    Zogg, D.
    Shafai, E.
    Geering, H. P.
    [J]. CONTROL ENGINEERING PRACTICE, 2006, 14 (12) : 1435 - 1444