Selvester score predicts implantable cardioverter defibrillator shocks in patients with non-ischemic cardiomyopathy

被引:1
作者
Arisoy, Fazil [1 ]
Ozcan Celebi, Ozlem [2 ]
Erbay, Ilke [2 ]
Tufekcioglu, Omac [2 ]
Aydogdu, Sinan [2 ]
Temizhan, Ahmet [2 ]
机构
[1] Kilis State Hosp, Dept Cardiol, Kilis, Turkey
[2] Univ Hlth Sci, Ankara City Hosp, Dept Cardiol, Ankara, Turkey
关键词
ICD; non ischemic cardiomyopathy; Selvester score; shock; SUDDEN CARDIAC DEATH; QRS SCORE; PRIMARY PREVENTION; THERAPY; MANAGEMENT; AMIODARONE;
D O I
10.1002/joa3.12571
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The implantable cardiac defibrillator is the cornerstone of prevention of sudden cardiac death in non-ischemic cardiomyopathy. The Selvester score, which is frequently investigated in ischemic cardiomyopathy, has not been investigated in the field of non-ischemic cardiomyopathy. Aim: The aim of this study was to evaluate the Selvester score for determining appropriate implantable cardiac defibrillator shocks in non-ischemic cardiomyopathy patients. Materials and methods: In all, 131 non-ischemic cardiomyopathy patients were included in the study. A simplified Selvester score was calculated from ECG data. Patients were divided into two groups according to whether they received ICD shock. Results: Of the patients, 28.2% received appropriate implantable cardiac defibrillator shock. The Selvester score was significantly higher in patients receiving appropriate shock when compared to patients with no implantable cardiac defibrillator shocks (8.8 +/- 4.6 vs 7.2 +/- 3.3, P = .040). The median QRS duration was significantly longer in patients receiving appropriate shock than in patients with no shocks (130.14 +/- 35.08 ms vs 120.12 +/- 20.57 ms, P = .045). We determined that the cutoff value for the Selvester score to predict ICD shocks was 6.5 with a sensitivity of 72.0% and a specificity of 83% (AUC = 0.717; %95 GA: 0.627-0.807, P < .001). Conclusion: Selvester score was higher in patients receiving appropriate shock than in patients who did not receive any implantable cardiac defibrillator shock. From this study, the Selvester score is associated with the risk of ventricular tachycardia/ventricular fibrillation in non-ischemic cardiomyopathy so that careful attention is necessary to manage the patients with high Selvester score.
引用
收藏
页码:1046 / 1051
页数:6
相关论文
共 50 条
  • [41] Prevalence of Appropriate Cardioverter-Defibrillator Shocks in 1038 Consecutive Patients With Implantable Cardioverter-Defibrillators
    Kruger, Adam
    Aronow, Wilbert S.
    Lai, Hoang
    Desai, Harit
    Singla, Atul
    Frishman, William H.
    Cohen, Martin
    Sorbera, Carmine
    AMERICAN JOURNAL OF THERAPEUTICS, 2009, 16 (04) : 323 - 325
  • [42] Shocks burden and increased mortality in implantable cardioverter-defibrillator patients
    Larsen, Gail K.
    Evans, John
    Lambert, William E.
    Chen, Yiyi
    Raitt, Merritt H.
    HEART RHYTHM, 2011, 8 (12) : 1881 - 1886
  • [43] Use of implantable cardioverter defibrillator in nonischaemic cardiomyopathy: a U-turn?
    Gaita, Fiorenzo
    Castagno, Davide
    Anselmino, Matteo
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2018, 19 : E63 - E67
  • [44] Cardioverter-defibrillator reduces mortality risk in eligible ischemic and non-ischemic cardiomyopathy patients: Sub-analysis of the multi- center Improve SCA study
    Singh, Balbir
    Hsieh, Yu-Cheng
    Liu, Yen -Bin
    Lin, Kuo-Hung
    Joung, Boyoung
    Rodriguez, Diego A.
    Chasnoits, Alexandr R.
    Huang, Dejia
    Zhang, Shu
    O'Brien, Janet E.
    Lexcen, Daniel R.
    Cerkvenik, Jeffrey
    Van Dorn, Brian
    Ching, Chi-Keong
    INDIAN HEART JOURNAL, 2023, 75 (02) : 115 - 121
  • [45] Pattern of late gadolinium enhancement predicts arrhythmic events in patients with non-ischemic cardiomyopathy
    Shin, Dong Geum
    Lee, Hye-Jeong
    Park, Junbeom
    Uhm, Jae-Sun
    Pak, Hui-Nam
    Lee, Moon-Hyoung
    Kim, Young Jin
    Joung, Boyoung
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 222 : 9 - 15
  • [46] Relation of multicenter automatic defibrillator implantation trial implantable cardioverter-defibrillator score with long-term cardiovascular events in patients with implantable cardioverter-defibrillator
    Uslu, Abdulkadir
    Dogan, Cem
    Duman, Hakan
    Tanboga, Ibrahim Halil
    Askin, Lutfu
    Sevimli, Serdar
    NORTHERN CLINICS OF ISTANBUL, 2019, 6 (01) : 40 - 47
  • [47] Myocardial Scar Characterization and Future Ventricular Arrhythmia in Patients With Ischemic Cardiomyopathy and an Implantable Cardioverter-Defibrillator
    Noordman, Alwin B. P.
    Maass, Alexander H.
    Groenveld, Hessel
    Mulder, Bart A.
    Rienstra, Michiel
    Blaauw, Yuri
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [48] Additional antitachycardia pacing programming strategies further reduce unnecessary implantable cardioverter-defibrillator shocks
    Joung, Boyoung
    Lexcen, Daniel R.
    Ching, Chi-Keong
    Silver, Marc T.
    Piccini, Jonathan P.
    Sterns, Laurence D.
    Rabinovich, Rafael
    Pickett, Robert A.
    Liu, Shufeng
    Brown, Mark L.
    Cheng, Alan
    HEART RHYTHM, 2020, 17 (01) : 98 - 105
  • [49] Feedback to providers improves evidence-based implantable cardioverter-defibrillator programming and reduces shocks
    Silver, Marc T.
    Sterns, Laurence D.
    Piccini, Jonathan P.
    Joung, Boyoung
    Ching, Chi-Keong
    Pickett, Robert A.
    Rabinovich, Rafael
    Liu, Shufeng
    Peterson, Brett J.
    Lexcen, Daniel R.
    HEART RHYTHM, 2015, 12 (03) : 545 - 553
  • [50] Timing of Prophylactic Implantable Cardioverter-Defibrillator Implantation in Patients With Cardiomyopathy
    Littmann, Laszlo
    Narveson, Sara Y.
    Fesel, Nicole M.
    Marconi, Sarah L.
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (01) : 161 - 162