Natural history and predictors of temporary epicardial pacemaker wire function in patients after open heart surgery

被引:25
作者
Elmi, F
Tullo, NG
Khalighi, K
机构
[1] Geisinger Med Ctr, Danville, PA 17822 USA
[2] St Josephs Hosp, Dept Med, Div Cardiol, Cardiac Electrophysiol Serv, Paterson, NJ USA
[3] Seton Hall Univ, Ctr Med, Grad Sch Med Educ, Paterson, NJ USA
[4] Med Coll Penn & Hahnemann Univ, Easton Hosp, Dept Med,Div Cardiol, Cardiac Electophysiol & Pacemaker Serv, Easton, PA USA
关键词
cardiac surgery; open heart surgery; temporary pacemaker wires;
D O I
10.1159/000067312
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Study Objectives: To assess the short-term reliability of temporary epicardial pacing wires in patients after open heart surgery and to determine the influence of preoperative factors on the performance of these wires. Patients and Methods: In this prospective, longitudinal cohort study, 60 patients (41 men) with a mean age of 66.8 +/- 8.9 years were studied for 5.3 +/- 1.1 days postoperatively. Each patient's history, physical findings, hemodynamics and echocardiographic data were analyzed. Postoperatively, capture threshold, the electrogram amplitude and slew rate, and the lead impedance were determined daily in both chambers. Results: Both atrial and ventricular thresholds increased significantly (p < 0.001) by the 4th postoperative day. The P-wave amplitudes were consistently less than half of the R-wave amplitudes. Both P-and R-wave amplitudes deteriorated significantly by the 2nd postoperative day (p < 0.001 and p < 0.02, respectively). Atrial and ventricular slew rates and lead impedance decreased significantly during the observation period (p < 0.002). Conclusion: Although both atrial and ventricular temporary epicardial leads are reliable for short-term use, their function deteriorates on a daily basis. Perioperative factors are generally not helpful in predicting the performance of temporary epicardial pacing wires. Copyright (C) 2002 S. Karger AG, Basel.
引用
收藏
页码:175 / 180
页数:6
相关论文
共 16 条
[1]   CLINICAL-EVALUATION OF A NEW TEMPORARY PACEMAKER WIRE [J].
ARIS, A ;
CAMARA, ML ;
PADRO, JM ;
BONNIN, JO ;
SOLE, JO ;
CARALPS, JM .
ANNALS OF THORACIC SURGERY, 1983, 36 (02) :228-230
[2]  
CURTIS JJ, 1977, SURGERY, V82, P888
[3]  
DEBELDER MA, 1990, PACE, V13, P231
[4]  
Del Nido P, 1989, J Card Surg, V4, P99, DOI 10.1111/j.1540-8191.1989.tb00262.x
[5]   TEMPORARY EXTERNAL DDD PACING AFTER CARDIAC OPERATIONS [J].
FERGUSON, TB ;
COX, JL .
ANNALS OF THORACIC SURGERY, 1991, 51 (05) :723-732
[6]   PACING THRESHOLDS OF TEMPORARY EPICARDIAL ELECTRODES - VARIATION WITH ELECTRODE TYPE, TIME, AND EPICARDIAL POSITION [J].
KALLIS, P ;
BATRICK, N ;
BINDI, F ;
MASCARO, G ;
CHATZIS, A ;
KEOGH, BE ;
PARKER, DJ ;
TREASURE, T .
ANNALS OF THORACIC SURGERY, 1994, 57 (03) :623-626
[7]   VARIATIONS IN DISCHARGE RATE OF DEMAND PACEMAKERS NOT DUE TO MALFUNCTION [J].
KASTOR, JA ;
BERKOVITS, BV ;
DESANCTIS, RW .
AMERICAN JOURNAL OF CARDIOLOGY, 1970, 25 (03) :344-+
[8]  
Khalighi Koroush, 1994, Chest, V106, p128S
[9]   Low-energy cardioversion with epicardial wire electrodes: New treatment of atrial fibrillation after open heart surgery [J].
Liebold, A ;
Wahba, A ;
Birnbaum, DE .
CIRCULATION, 1998, 98 (09) :883-886
[10]   Performance of temporary epicardial stainless steel wire electrodes used to treat atrial fibrillation:: A study in patients following open heart surgery [J].
Liebold, A ;
Rödig, G ;
Birnbaum, DE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (02) :315-319