Glaucoma detection by Stratus OCT

被引:59
作者
Hougaard, Jesper Leth [1 ]
Heijl, Anders [1 ]
Bengtsson, Boel [1 ]
机构
[1] Lund Univ, Malmo Univ Hosp, Dept Clin Sci, SE-20502 Malmo, Sweden
关键词
diagnosis; glaucoma; optical coherence tomography; retinal nerve fiber layer; Stratus OCT;
D O I
10.1097/IJG.0b013e318032e4d4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the diagnostic accuracy of retinal nerve fiber layer thickness (RNFLT) summary report parameters from Stratus optical coherence tomography (OCT) in glaucoma patients. Patients and Methods: We obtained Stratus OCT measurements of peripapillary circle scans (average values) of the regular image resolution "FAST RNFLT" protocol, and of 1 circle scan of the high resolution "RNFLT" protocol in one eye of each of 62 glaucoma patients with mild or moderate visual field (VF) loss and 90 healthy subjects. Sensitivity, specificity, and diagnostic accuracy [(true positive + true negative)/all] were evaluated for all summary report parameters including the newer (eg, "Imax," the maximum thickness point in the inferior quadrant) at the normative limits of the Stratus OCT. Results: The diagnostic accuracy of full circle RNFLT using the 5% normal limit was 89% with the FAST RNFLT and 87% with the RNFLT protocol; this was at least as good as any other parameter. The diagnostic performance of the 2 protocols did not differ significantly for most parameters. In eyes with mild VF loss (n = 39) diagnostic sensitivities reached 72% and 77% at specificities >= 95% using the FAST RNFLT and RNFLT protocol, respectively. Conclusions: The diagnostic accuracy of the full circle RNFLT was as good as any Stratus OCT parameter on the basis of the peripapillary RNFL thickness measurements, including localized measurements. The sensitivity was moderately high in patients with mild glaucomatous VF loss. There seems to be room for further development of OCT interpretation tools for early diagnosis of glaucoma.
引用
收藏
页码:302 / 306
页数:5
相关论文
共 16 条
[1]   Relevance vector machine and support vector machine classifier analysis of scanning laser polarimetry retinal nerve fiber layer measurements [J].
Bowd, C ;
Medeiros, FA ;
Zhang, ZH ;
Zangwill, LM ;
Hao, JC ;
Lee, TW ;
Sejnowski, TJ ;
Weinreb, RN ;
Goldbaum, MH .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (04) :1322-1329
[2]   Sensitivity and specificity of the StratusOCT for perimetric glaucoma [J].
Budenz, DL ;
Michael, A ;
Chang, RT ;
McSoley, J ;
Katz, J .
OPHTHALMOLOGY, 2005, 112 (01) :3-9
[3]   Optical coherence tomography machine learning classifiers for glaucoma detection: A preliminary study [J].
Burgansky-Eliash, Z ;
Wollstein, G ;
Chu, TJ ;
Ramsey, JD ;
Glymour, C ;
Noecker, RJ ;
Ishikawa, H ;
Schuman, JS .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (11) :4147-4152
[4]   Analysis of GDx-VCC polarimetry data by wavelet-Fourier analysis across glaucoma stages [J].
Essock, EA ;
Zheng, YF ;
Gunvant, P .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (08) :2838-2847
[5]   Fourier analysis of optical coherence tomography and scanning laser polarimetry retinal nerve fiber layer measurements in the diagnosis of glaucoma [J].
Essock, EA ;
Sinai, MJ ;
Bowd, C ;
Zangwill, LM ;
Weinreb, RN .
ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (09) :1238-1245
[6]  
Harwerth RS, 1999, INVEST OPHTH VIS SCI, V40, P2242
[7]   Modelling the normal retinal nerve fibre layer thickness as measured by Stratus optical coherence tomography [J].
Hougaard, Jesper Leth ;
Ostenfeld, Carl ;
Heijl, Anders ;
Bengtsson, Boel .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (12) :1607-1614
[8]  
HOUGAARD JL, 2006, IN PRESS ACTA OPHTHA
[9]  
Kerrigan-Baumrind LA, 2000, INVEST OPHTH VIS SCI, V41, P741
[10]   Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography [J].
Medeiros, FA ;
Zangwill, LM ;
Bowd, C ;
Vessani, RM ;
Susanna, R ;
Weinreb, RN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (01) :44-55