共 50 条
Definition and validation of a system for classifying the undersized Corail femoral stem in total hip arthroplasty
被引:6
|作者:
McConnell, Jamie S.
[1
]
Syed, Farhan A.
[2
]
Saunders, Paul
[2
]
Kattimani, Raviprasad
[3
]
Ugwuoke, Anthony
[4
]
Magra, Merzesh
[5
]
Young, Steve K.
[2
]
机构:
[1] Barnet & Chase Farm Hosp NHS Trust, London, England
[2] Warwick Hosp, Warwick, England
[3] Macclesfield Hosp, Macclesfield, Cheshire, England
[4] Countess Chester Hosp, Chester, Cheshire, England
[5] Univ Hosp Morecambe Bay NHS Fdn Trust, Kendal, England
关键词:
Hydroxyapatite;
uncemented;
undersizing;
D O I:
10.1177/1120700021996001
中图分类号:
R826.8 [整形外科学];
R782.2 [口腔颌面部整形外科学];
R726.2 [小儿整形外科学];
R62 [整形外科学(修复外科学)];
学科分类号:
摘要:
Introduction: The uncemented total hip arthroplasty relies on a secure initial fixation of the femoral stem to achieve osseointegration. Undersizing of the femoral implant compromises this. Surgeons routinely review postoperative radiographs to assess appropriate sizing, but existing methods of assessment lack standardisation. We present a system of accurately and reliably classifying radiological undersizing, which will help us better understand the factors that might have led to undersizing. Aim: To describe and evaluate a classification system for assessing radiological undersizing of the uncemented stem in hip arthroplasty. Method: We conducted a retrospective review of 1,337 consecutive hip arthroplasties using the Corail stem. Two independent investigators reviewed post-operative radiographs and classified them as either appropriately sized or undersized. Undersized stems were sub-categorised into four subtypes: uniformly undersized, varus undersized, valgus undersized or 'cocktail-glass' undersized. Inter- and intra-observer agreement was determined. The accuracy of our classification system was validated by comparison with digital re-templating. We further assessed patient demographics and stem size in relation to sizing. Results: 1 in 5 cases (19.75%) were deemed radiologically undersized. The commonest subtypes of undersizing were uniformly (47%) and varus (39%) undersized. When assessing sizing and subtype categorisation, inter-observer agreement was 89-92% and intra-observer agreement 86%. Classification decisions showed 92% and 97% accuracy for uniformly undersizing and varus undersizing respectively when validated against digital re-templating. Age, gender and smaller stem size were significantly associated with radiological undersizing. The Corail KLA model (125 degrees neck) was found to have a higher incidence of stems undersized in varus. Conclusions: This study describes and validates a classification system for the analysis of radiological undersizing.
引用
收藏
页码:737 / 746
页数:10
相关论文