The Effects of the Odstock Drop Foot Stimulator on Perceived Quality of Life for People With Stroke and Multiple Sclerosis

被引:31
作者
Barrett, Catherine [1 ]
Taylor, Paul [2 ]
机构
[1] Bournemouth Univ, Sch Hlth & Social Care, Poole BH12 5BB, Dorset, England
[2] Bournemouth Univ, Sch Design Engn & Comp, Poole BH12 5BB, Dorset, England
来源
NEUROMODULATION | 2010年 / 13卷 / 01期
关键词
FES; gait; MS; quality of life; stroke; RANDOMIZED CONTROLLED-TRIAL; ASSISTIVE TECHNOLOGY; WALKING; SPEED;
D O I
10.1111/j.1525-1403.2009.00250.x
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Introduction. Gait speed is often used as a proxy for gait quality. However, some users of FES devices for correction of dropped foot choose to continue to use the device despite no significant change in speed. The Psychosocial Impact of Assistive Devices Scale (PIADS) was used to evaluate the effects of the Odstock Dropped Foot Stimulator (ODFS) on perceived quality of life (QOL) for people with stroke and multiple sclerosis (MS) and was compared with change in walking speed. Method. A total of 21 people with stroke and 20 with MS completed the PIADS questionnaire after 18 weeks of using the ODFS. Walking speed was recorded more than 10 m with and without stimulation. Results. Both groups recorded positive median scores for all three sections of the PIADS questionnaire: Competence (1.25 stroke, 0.91 MS), Adaptability (1.25 stroke, 0.50 MS), and Self-esteem (0.88 stroke, 0.75 MS). These were significantly greater for the stroke than the MS group for Competence, p = 0.04 and Adaptability, p = 0.006. There was no significant correlation between changes in PIADS and changes in walking speed. Conclusions. FES for correction of dropped foot has a beneficial effect on perceived QOL for people with stroke and MS but this is not correlated with an objective measures of gait.
引用
收藏
页码:58 / 64
页数:7
相关论文
共 24 条
[1]  
[Anonymous], 1998, REHAB COMMUNITY CARE
[2]   A randomized trial to investigate the effects of functional electrical stimulation and therapeutic exercise on walking performance for people with multiple sclerosis [J].
Barrett, C. L. ;
Mann, G. E. ;
Taylor, P. N. ;
Strike, P. .
MULTIPLE SCLEROSIS JOURNAL, 2009, 15 (04) :493-504
[3]   Phase II trial to evaluate the ActiGait implanted drop-foot stimulator in established hemiplegia [J].
Burridge, Jane ;
Haugland, Morten ;
Larsen, Birgit ;
Pickering, Ruth M. ;
Svaneborg, Niels ;
Iversen, Helle K. ;
Christensen, P. Brogger ;
Haase, Jens ;
Brennum, Jannick ;
Sinkjaer, Thomas .
JOURNAL OF REHABILITATION MEDICINE, 2007, 39 (03) :212-218
[4]   The effects of common peroneal stimulation on the effort and speed of walking: a randomized controlled trial with chronic hemiplegic patients [J].
Burridge, JH ;
Taylor, PN ;
Hagan, SA ;
Wood, DE ;
Swain, ID .
CLINICAL REHABILITATION, 1997, 11 (03) :201-210
[5]  
Day H., 1996, Canadian Journal of Rehabilitation, V9, P159, DOI DOI 10.1080/09638280110066343
[6]   Effects of a new radio frequency - Controlled neuroprosthesis on gait symmetry and Rhythmicity in patients with chronic hemiparesis [J].
Hausdorff, Jeffrev M. ;
Ring, Haim .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2008, 87 (01) :4-13
[7]   Persisting symptoms and carers' views of outcome after subarachnoid haemorrhage [J].
Hellawell, DJ ;
Taylor, R ;
Pentland, B .
CLINICAL REHABILITATION, 1999, 13 (04) :333-340
[8]  
HOFFER JA, 2005, IN RES FULL IMPL NEU
[9]  
JUTAI J, 2003, TECHNOL DISABIL, V14, P107
[10]  
Jutai J., 2002, Technology and Disability, V14, P107, DOI [10.3233/tad-2002-14305, DOI 10.3233/TAD-2002-14305]