Mineralization of mefenamic acid from hospital wastewater using electro-Fenton degradation: Optimization and identification of removal mechanism issues

被引:53
|
作者
Dolatabadi, Maryam [1 ,2 ]
Ahmadzadeh, Saeid [3 ,4 ]
Ghaneian, Mohammad T. [1 ]
机构
[1] Shahid Sadoughi Univ Med Sci, Dept Environm Hlth Engn, Environm Sci & Technol Res Ctr, Yazd, Iran
[2] Kerman Univ Med Sci, Student Res Comm, Kerman, Iran
[3] Kerman Univ Med Sci, Inst Neuropharmacol, Pharmaceut Res Ctr, Kerman, Iran
[4] Kerman Univ Med Sci, Food Drug & Cosmet Safety Res Ctr, Kerman, Iran
关键词
degradation; electro-Fenton process; hospital wastewater; Mefenamic acid; CARBON-NANOTUBE FILTER; EFFICIENT REMOVAL; AQUEOUS-SOLUTIONS; BISPHENOL-A; ADSORPTION; KINETICS;
D O I
10.1002/ep.13380
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Mefenamic acid (MFA) is a nonsteroidal anti-inflammatory drug widely used for the short-term treatment of mild to moderate pain as well as treatment of primary dysmenorrhea and for decreasing the pain and blood loss during menstrual periods. Since MFA has been detected in raw and sewage water worldwide, the current work deals with the optimizing of removal of MFA from hospital wastewater using the electro-Fenton (E-Fenton) process. A cylindrical Pyrex reactor containing 250 ml of wastewater was employed for treatment investigation. The effects of main variables on the removal process were investigated and the optimum experimental condition was obtained with adequate desirability under the response surface methodology. The obtained results revealed that the removal efficiency of 95.3% was achieved under the optimal experimental condition, including MFA initial concentration of 7.0 mg L-1, the H2O2 dosage of 700 mu l/L, the current density of 6.6 mA cm(-2), and the reaction time of 12 min. The removal mechanism studies showed that (OH)-O-center dot as the dominant radical species plays the main role in E-Fenton process. The MFA removal followed the pseudo-first-order kinetic model. Under the optimum condition of the E-Fenton process, the removal efficiency of MFA from synthetic wastewater was in satisfactory agreement with the real hospital wastewater treatment.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Optimization of Fenton and electro-Fenton oxidation of biologically treated coking wastewater using response surface methodology
    Zhu, Xiaobiao
    Tian, Jinping
    Liu, Rui
    Chen, Lujun
    SEPARATION AND PURIFICATION TECHNOLOGY, 2011, 81 (03) : 444 - 450
  • [22] ELECTRO-FENTON REMOVAL OF POLYVINYL ALCOHOL FROM AQUEOUS SOLUTIONS USING AN ACTIVATED CARBON FIBER CATHODE
    Chou, Wei-Lung
    Chen, Li-Shien
    Wang, Chih-Ta
    Lee, Sheng-Ru
    FRESENIUS ENVIRONMENTAL BULLETIN, 2012, 21 (12): : 3735 - 3742
  • [23] Medical laboratory wastewater treatment by electro-fenton process: Modeling and optimization using central composite design
    Basturk, Irfan
    Varank, Gamze
    Murat Hocaoglu, Selda
    Yazici Guvenc, Senem
    WATER ENVIRONMENT RESEARCH, 2021, 93 (03) : 393 - 408
  • [24] COD removal from real dyeing wastewater by electro-Fenton technology using an activated carbon fiber cathode
    Wang, Chih-Ta
    Chou, Wei-Lung
    Chung, Mei-Hui
    Kuo, Yi-Ming
    DESALINATION, 2010, 253 (1-3) : 129 - 134
  • [25] Enhanced Electro-Fenton Mineralization of Acid Orange 7 Using a Carbon Nanotube Fiber-Based Cathode
    Thi Xuan Huong Le
    Aieman, Beien
    Vilatela, Juan J.
    Bechelany, Mikhael
    Cretin, Marc
    FRONTIERS IN MATERIALS, 2018, 5
  • [26] Removal of the Insecticide Imidacloprid from Water in Commercial Formulation using Electro-Fenton and Photo-Electro-Fenton: Optimization of COD Removal through Response Surface Methodology RSM-CCD
    Iberache, Noureddine
    Titchou, Fatima Ezzahra
    Errami, Mohamed
    Ben-Aazza, Said
    Driouiche, Ali
    Akbour, Rachid Ait
    Hamdani, Mohamed
    Hadf, Abdallah
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2024, 196
  • [27] Prompt removal of antibiotic by adsorption/electro-Fenton degradation using an iron-doped perlite as heterogeneous catalyst
    Puga, A.
    Rosales, E.
    Pazos, M.
    Sanroman, M. A.
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2020, 144 : 100 - 110
  • [28] Optimization and modeling of electro-Fenton process for treatment of phenolic wastewater using nickel and sacrificial stainless steel anodes
    Radwan, Mahmoud
    Alalm, Mohamed Gar
    Eletriby, Hisham
    JOURNAL OF WATER PROCESS ENGINEERING, 2018, 22 : 155 - 162
  • [29] Modeling and optimization of advanced oxidation treatment of beer industry wastewater using Electro-Fenton process
    Thirugnanasambandham, K.
    Sivakumar, V.
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2015, 34 (04) : 1072 - 1079
  • [30] BOX-BEHNKEN DESIGN OPTIMIZATION OF ELECTRO-FENTON/-PERSULFATE PROCESSES FOLLOWING THE ACIDIFICATION FOR TSS REMOVAL FROM BIODIESEL WASTEWATER
    Yazici Guvenc, Senem
    Varank, Gamze
    SIGMA JOURNAL OF ENGINEERING AND NATURAL SCIENCES-SIGMA MUHENDISLIK VE FEN BILIMLERI DERGISI, 2020, 38 (04): : 1767 - 1780