Optimal pressure sensor placement and assessment for leak location using a relaxed isolation index: Application to the Barcelona water network

被引:39
作者
Cuguero-Escofet, Miquel A. [1 ]
Puig, Vicenc [1 ]
Quevedo, Joseba [1 ]
机构
[1] Polytech Univ Catalonia UPC, CS2AC, Supervis Safety & Automat Control Res Ctr, Terrassa Campus,Gaia Res Bldg, Barcelona 08222, Spain
关键词
Sensor placement; Fault detection and isolation; Leak location; Correlation coefficient; Water distribution networks; OPTIMIZATION;
D O I
10.1016/j.conengprac.2017.03.003
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Water distribution networks are large complex systems affected by leaks, which often entail high costs and may severely jeopardise the overall water distribution performance. Successful leak location is paramount in order to minimize the impact of these leaks when occurring. Sensor placement is a key issue in the leak location process, since the overall performance and success of this process highly depends on the choice of the sensors gathering data from the network. Common problems when isolating leaks in large scale highly gridded real water distribution networks include leak mislabelling and the obtention of large number of possible leak locations. This is due to similarity of leak effect in the measurements, which may be caused by topological issues and led to incomplete coverage of the whole network. The sensor placement strategy may minimize these undesired effects by setting the sensor placement optimisation problem with the appropriate assumptions (e.g. geographically cluster alike leak behaviors) and by taking into account real aspects of the practical application, such as the acceptable leak location distance. In this paper, a sensor placement methodology considering these aspects and a general sensor distribution assessment method for leak diagnosis in water distribution systems is presented and exemplified with a small illustrative case study. Finally, the proposed method is applied to two real District Metered Areas (DMAs) located within the Barcelona water distribution network.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 25 条
[1]   Optimal Design of Sensor Placement in Water Distribution Networks [J].
Aral, Mustafa M. ;
Guan, Jiabao ;
Maslia, Morris L. .
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT-ASCE, 2010, 136 (01) :5-18
[2]   Model-based leak detection and location in water distribution networks considering an extended-horizon analysis of pressure sensitivities [J].
Casillas Ponce, Myrna V. ;
Garza Castanon, Luis E. ;
Puig Cayuela, Vicenc .
JOURNAL OF HYDROINFORMATICS, 2014, 16 (03) :649-670
[3]   Entropy-Based Sensor Placement Optimization for Waterloss Detection in Water Distribution Networks [J].
Christodoulou, Symeon E. ;
Gagatsis, Anastasis ;
Xanthos, Savvas ;
Kranioti, Sofia ;
Agathokleous, Agathoklis ;
Fragiadakis, Michalis .
WATER RESOURCES MANAGEMENT, 2013, 27 (13) :4443-4468
[4]   A selective literature review of transient-based leak detection methods [J].
Colombo, Andrew F. ;
Lee, Pedro ;
Karney, Bryan W. .
JOURNAL OF HYDRO-ENVIRONMENT RESEARCH, 2009, 2 (04) :212-227
[5]  
Farley M., 2003, LOSSES WATER DISTRIB
[6]   An introduction to ROC analysis [J].
Fawcett, Tom .
PATTERN RECOGNITION LETTERS, 2006, 27 (08) :861-874
[7]   GENETIC ALGORITHMS - A POWERFUL TOOL FOR LARGE-SCALE NONLINEAR OPTIMIZATION PROBLEMS [J].
GALLAGHER, K ;
SAMBRIDGE, M .
COMPUTERS & GEOSCIENCES, 1994, 20 (7-8) :1229-1236
[8]   Acoustic Detection of Leaks in Water Pipelines Using Measurements inside Pipe [J].
Khulief, Y. A. ;
Khalifa, A. ;
Ben Mansour, R. ;
Habib, M. A. .
JOURNAL OF PIPELINE SYSTEMS ENGINEERING AND PRACTICE, 2012, 3 (02) :47-54
[9]  
Koza JR, 1995, WESCON 95 - CONFERENCE RECORD, P589, DOI 10.1109/WESCON.1995.485447
[10]   Efficient Sensor Placement Optimization for Securing Large Water Distribution Networks [J].
Krause, Andreas ;
Leskovec, Jure ;
Guestrin, Carlos ;
VanBriesen, Jeanne ;
Faloutsos, Christos .
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT-ASCE, 2008, 134 (06) :516-526