Selective and sensitive liquid chromatography-tandem mass spectrometry method for the determination of levonorgestrel in human plasma

被引:31
作者
Theron, HB [1 ]
Coetzee, C [1 ]
Sutherland, FCW [1 ]
Wiesner, JL [1 ]
Swart, KJ [1 ]
机构
[1] PAREXEL, Clin Res Org, FARMOVS, ZA-9324 Brandhof, South Africa
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2004年 / 813卷 / 1-2期
关键词
levonorgestrel; 17-alpha-methyltestosterone; liquid-liquid extraction; plasma; liquid chromatography; mass spectrometry; atmospheric pressure photospray ionisation (APPI);
D O I
10.1016/j.jchromb.2004.10.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A selective, sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of levonorgestrel in plasma was developed. An Applied Biosystems API 3000 triple quadrupole mass spectrometer set to multiple reaction monitoring (MRM) mode, using atmospheric pressure photospray ionisation (APPI) in the positive mode. Using 17-alpha-methyltestosterone as internal standard (IS), liquid-liquid extraction was followed by reversed phase liquid chromatography using a phenyl-hexyl column and tandem mass spectrometric detection. The mean recovery for levonorgestrel and 17-alpha-methyltestosterone was 99.5 and 62.9%, respectively. The method was validated from 0.265 to 130 ng levonorgestrel/ml plasma with the lower limit of quantification (LLOQ) set at 0.265 ng/ml. This assay method makes use of the increased sensitivity and selectivity of tandem mass spectrometric (MS/MS) detection, allowing for a rapid (extraction and chromatography) and selective method for the determination of levonorgestrel in human plasma. The assay method was used in a pharmacokinetic study to quantify levonorgestrel in human plasma samples generated after administrating a single oral dose of 1.5 mg levonorgestrel to healthy female volunteers for up to five half lives. The total chromatographic runtime of this method was 5.0 min per sample, allowing for analysis of a large number of samples per batch. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:331 / 336
页数:6
相关论文
共 10 条
[1]   Micellar electrokinetic capillary chromatography as an alternative method for the determination of ethinylestradiol and levo-norgestrel [J].
Berzas, JJ ;
Del Castillo, B ;
Castañeda, G ;
Pinilla, MJ .
TALANTA, 1999, 50 (02) :261-268
[2]   Determination of steroid sex hormones and related synthetic compounds considered as endocrine disrupters in water by fully automated on-line solid-phase extraction-liquid chromatography-diode array detection [J].
de Alda, MJL ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 2001, 911 (02) :203-210
[3]  
JOHNSTON MA, 1981, J CHROMATOGR, V216, P269
[4]   Determination of endogenous and exogenous estrogens in effluents from sewage treatment plants at the ng/L-level [J].
Kuch, HM ;
Ballschmiter, K .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (04) :392-395
[5]   Cortisol and cortisone analysis in serum and plasma by atmospheric pressure photoionization tandem mass spectrometry [J].
Kushnir, MM ;
Neilson, R ;
Roberts, WL ;
Rockwood, AL .
CLINICAL BIOCHEMISTRY, 2004, 37 (05) :357-362
[6]   Determination of steroid hormones by membrane inlet mass spectrometry and desorption chemical ionization [J].
Lauritsen, FR ;
Rose, J .
ANALYST, 2000, 125 (09) :1577-1581
[7]   Matrix effect in quantitative LC/MS/MS analyses of biological fluids: A method for determination of finasteride in human plasma at picogram per milliliter concentrations [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :882-889
[8]   Determination of levonorgestrel in human serum by liquid chromatographic-electrospray tandem mass spectrometry [J].
Wang, QG ;
Wu, ZP ;
Wang, YM ;
Luo, G ;
Wu, ER ;
Gao, XF ;
Li, G .
ANALYTICAL LETTERS, 2001, 34 (01) :103-112
[9]   A SENSITIVE DIRECT RADIOIMMUNOASSAY FOR ASSESSING D-NORGESTREL LEVELS IN HUMAN-PLASMA [J].
WATSON, TG ;
STEWART, BJ .
ANNALS OF CLINICAL BIOCHEMISTRY, 1988, 25 :280-287
[10]  
*WHO, 1985, B WORLD HEALTH ORGAN, V63, P485