Multi-parameter quantitative mapping of R1, R2*, PD, and MTsat is reproducible when accelerated with Compressed SENSE

被引:6
作者
Berg, Ronja C. [1 ,2 ]
Leutritz, Tobias [3 ]
Weiskopf, Nikolaus [3 ,4 ]
Preibisch, Christine [1 ,2 ,3 ,5 ]
机构
[1] Tech Univ Munich, Sch Med, Dept Diagnost & Intervent Neuroradiol, Klinikum rechts Isar, Ismaninger Str22, D-81675 Munich, Germany
[2] Tech Univ Munich, Sch Med, Dept Neurol, Klinikum Rechts Isar, Munich, Germany
[3] Max Planck Inst Human Cognit & Brain Sci, Dept Neurophys, Leipzig, Germany
[4] Univ Leipzig, Felix Bloch Inst Solid State Phys, Fac Phys & Earth Sci, Leipzig, Germany
[5] Tech Univ Munich, TUM Neuroimaging Ctr, Sch Med, Klinikum rechts Isar, Munich, Germany
基金
欧洲研究理事会;
关键词
Multi-parameter mapping; Quantitative MRI; Compressed SENSE; Imaging acceleration; Reproducibility; NMR RELAXATION-TIMES; HUMAN BRAIN; 1.5; T; MRI; TISSUE; FREQUENCY; ACCURACY; VALUES; MOTION; FLASH;
D O I
10.1016/j.neuroimage.2022.119092
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Multi-parameter mapping (MPM) magnetic resonance imaging (MRI) provides quantitative estimates of the longitudinal and effective transverse relaxation rates R1 and R2 *, proton density (PD), and magnetization transfer saturation (MTsat). Thereby, MPM enables better comparability across sites and time than conventional weighted MRI. However, for MPM, several contrasts must be acquired, resulting in prolonged measurement durations and thus preventing MPM's application in clinical routines. State-of-the-art imaging acceleration techniques such as Compressed SENSE (CS), a combination of compressed sensing and sensitivity encoding, can be used to reduce the scan time of MPM. However, the accuracy and precision of the resulting quantitative parameter maps have not been systematically evaluated. In this study, we therefore investigated the effect of CS acceleration on the fidelity and reproducibility of MPM acquisitions. In five healthy volunteers and in a phantom, we compared MPM metrics acquired without imaging acceleration, with the standard acceleration (SENSE factor 2.5), and with Compressed SENSE with acceleration factors 4 and 6 using a 32-channel head coil. We evaluated the reproducibility and repeatability of accelerated MPM using data from three scan sessions in gray and white matter volumes-of-interest (VOIs). Accelerated MPM provided precise and accurate quantitative parameter maps. For most parameters, the results of the CS-accelerated protocols correlated more strongly with the non-accelerated protocol than the standard SENSE-accelerated protocols. Furthermore, for most VOIs and contrasts, coefficients of variation were lower when calculated from data acquired with different imaging accelerations within a single scan session than from data acquired in different scan sessions with the same acceleration method. These results suggest that MPM with Compressed SENSE acceleration factors up to at least 6 yields reproducible quantitative parameter maps that are highly comparable to those acquired without imaging acceleration. Compressed SENSE can thus be used to considerably reduce the scan duration of R1, R2*, PD, and MTsat mapping, and is highly promising for clinical applications of MPM.
引用
收藏
页数:14
相关论文
共 83 条
[1]   Accelerated Isotropic Sub-Millimeter Whole-Heart Coronary MRI: Compressed Sensing Versus Parallel Imaging [J].
Akcakaya, Mehmet ;
Basha, Tamer A. ;
Chan, Raymond H. ;
Manning, Warren J. ;
Nezafat, Reza .
MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) :815-822
[2]   Unified segmentation [J].
Ashburner, J ;
Friston, KJ .
NEUROIMAGE, 2005, 26 (03) :839-851
[3]  
Balbastre Y., ARXIV PREPRINT ARXIV
[4]   T1 mapping with the variable flip angle technique: A simple correction for insufficient spoiling of transverse magnetization [J].
Baudrexel, Simon ;
Noeth, Ulrike ;
Schuere, Jan-Ruediger ;
Deichmann, Ralf .
MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (06) :3082-3092
[5]   Non-invasive mapping of connections between human thalamus and cortex using diffusion imaging [J].
Behrens, TEJ ;
Johansen-Berg, H ;
Woolrich, MW ;
Smith, SM ;
Wheeler-Kingshott, CAM ;
Boulby, PA ;
Barker, GJ ;
Sillery, EL ;
Sheehan, K ;
Ciccarelli, O ;
Thompson, AJ ;
Brady, JM ;
Matthews, PM .
NATURE NEUROSCIENCE, 2003, 6 (07) :750-757
[6]  
Berg R., 2020, EVALUATING COMPRESSE
[7]   A REVIEW OF H-1 NUCLEAR-MAGNETIC-RESONANCE RELAXATION IN PATHOLOGY - ARE T1 AND T2 DIAGNOSTIC [J].
BOTTOMLEY, PA ;
HARDY, CJ ;
ARGERSINGER, RE ;
ALLENMOORE, G .
MEDICAL PHYSICS, 1987, 14 (01) :1-37
[8]  
BOTTOMLEY PA, 1984, MED PHYS, V11, P425, DOI 10.1118/1.595535
[9]   Comparison of compressed SENSE and SENSE for quantitative liver MRI in children and young adults [J].
Boyarko, Alexander C. ;
Dillman, Jonathan R. ;
Tkach, Jean A. ;
Pednekar, Amol S. ;
Trout, Andrew T. .
ABDOMINAL RADIOLOGY, 2021, 46 (10) :4567-4575
[10]   T2 relaxation time of the normal-appearing white matter is related to the cognitive status in cerebral small vessel disease [J].
Brandhofe, Annemarie ;
Stratmann, Christoph ;
Schuere, Jan-Rudiger ;
Pilatus, Ulrich ;
Hattingen, Elke ;
Deichmann, Ralf ;
Noeth, Ulrike ;
Wagner, Marlies ;
Gracien, Rene-Maxime ;
Seiler, Alexander .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2021, 41 (07) :1767-1777