Reducing aeration energy consumption in a large-scale membrane bioreactor: Process simulation and engineering application

被引:83
|
作者
Sun, Jianyu [1 ]
Liang, Peng [1 ]
Yan, Xiaoxu [1 ]
Zuo, Kuichang [1 ]
Xiao, Kang [1 ,2 ]
Xia, Junlin [1 ]
Qiu, Yong [1 ]
Wu, Qing [1 ]
Wu, Shijia [1 ]
Huang, Xia [1 ]
Qi, Meng [1 ]
Wen, Xianghua [1 ]
机构
[1] Tsinghua Univ, Sch Environm, State Key Joint Lab Environm Simulat & Pollut Con, Beijing 100084, Peoples R China
[2] Univ Chinese Acad Sci, Coll Resources & Environm, Beijing 100049, Peoples R China
关键词
Membrane bioreactor; Ammonia-N-based aeration control strategy; Simulation; Engineering application; ACTIVATED-SLUDGE MODEL; WASTE-WATER TREATMENT; OPTIMIZATION; DESIGN; STATE; MBR;
D O I
10.1016/j.watres.2016.02.026
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Reducing the energy consumption of membrane bioreactors (MBRs) is highly important for their wider application in wastewater treatment engineering. Of particular significance is reducing aeration in aerobic tanks to reduce the overall energy consumption. This study proposed an in situ ammonia-N-based feedback control strategy for aeration in aerobic tanks; this was tested via model simulation and through a large-scale (50,000 m(3)/d) engineering application. A full-scale MBR model was developed based on the activated sludge model (ASM) and was calibrated to the actual MBR. The aeration control strategy took the form of a two-step cascaded proportion-integration (PI) feedback algorithm. Algorithmic parameters were optimized via model simulation. The strategy achieved real-time adjustment of aeration amounts based on feedback from effluent quality (i.e., ammonia-N). The effectiveness of the strategy was evaluated through both the model platform and the full-scale engineering application. In the former, the aeration flow rate was reduced by 15-20%. In the engineering application, the aeration flow rate was reduced by 20%, and overall specific energy consumption correspondingly reduced by 4% to 0.45 kWh/m(3)-effluent, using the present practice of regulating the angle of guide vanes of fixed-frequency blowers. Potential energy savings are expected to be higher for MBRs with variable-frequency blowers. This study indicated that the ammonia-N-based aeration control strategy holds promise for application in full-scale MBRs. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:205 / 213
页数:9
相关论文
共 50 条
  • [1] Configuration of a simple dialysis membrane bioreactor suitable for large-scale application
    Kleuser, B
    Kocher, HP
    Memmert, K
    Stenz, M
    Straubhaar, B
    Zurini, M
    ANIMAL CELL TECHNOLOGY: PRODUCTS FROM CELLS, CELLS AS PRODUCTS, 1999, : 303 - 305
  • [2] Energy Consumption Simulation of the Air Conditioning System in Large-scale Buildings
    Zhang, Guangming
    Shen, Xue
    Tang, Guizhong
    APPLIED ENERGY TECHNOLOGY, PTS 1 AND 2, 2013, 724-725 : 1506 - 1509
  • [3] APPLICATION OF CHEMICAL-ENGINEERING TO LARGE-SCALE SOLAR-ENERGY
    CHUBB, TA
    NEMECEK, JJ
    SIMMONS, DE
    SOLAR ENERGY, 1978, 20 (03) : 219 - 224
  • [4] Application of filling process simulation in MIM of large-scale complex part
    State Key Laboratory of Powder Metallurgy, Central South University, Changsha 410083, China
    不详
    Fenmo Yejin Cailiao Kexue yu Gongcheng, 2009, 2 (89-95):
  • [5] Aeration optimization of large-scale membrane bioreactors in a sewage treatment plant
    Tang, M.
    Liu, J.
    WATER PRACTICE AND TECHNOLOGY, 2019, 14 (01): : 198 - 202
  • [6] Reducing energy consumption in large-scale sensor networks through hierarchical aggregation and sleeping schedule
    Li, Wenfeng
    Shen, Lianfeng
    WMSCI 2007: 11TH WORLD MULTI-CONFERENCE ON SYSTEMICS, CYBERNETICS AND INFORMATICS, VOL II, PROCEEDINGS, 2007, : 74 - 79
  • [7] Numerical simulation of aeration flow phenomena in bench-scale submerged flat membrane bioreactor
    Kim, Dae Chun
    Chung, Kun Yong
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2019, 69 : 241 - 254
  • [8] Large-scale building simulation using cloud computing for estimating lifecycle energy consumption
    Richman, Russell
    Zirnhelt, Hayes
    Fix, Stuart
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2014, 41 (03) : 252 - 262
  • [9] Development of a membrane dialysis bioreactor and its application to a large-scale culture of a symbiotic bacterium, Symbiobacterium thermophilum
    Ueda, K
    Saka, H
    Ishikawa, Y
    Kato, T
    Takeshita, Y
    Shiratori, H
    Ohno, M
    Hosono, K
    Wada, M
    Ishikawa, Y
    Beppu, T
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2002, 60 (03) : 300 - 305
  • [10] Development of a membrane dialysis bioreactor and its application to a large-scale culture of a symbiotic bacterium, Symbiobacterium thermophilum
    K. Ueda
    H. Saka
    Yoshiyuki Ishikawa
    T. Kato
    Y. Takeshita
    H. Shiratori
    M. Ohno
    K. Hosono
    M. Wada
    Yohichi Ishikawa
    T. Beppu
    Applied Microbiology and Biotechnology, 2002, 60 : 300 - 305