Phenylaminopropyl silica - a new specific stationary phase for high-performance liquid chromatography of phenols

被引:38
作者
Kiseleva, MG [1 ]
Nesterenko, PN [1 ]
机构
[1] Moscow MV Lomonosov State Univ, Dept Chem, Div Analyt Chem, Moscow 119899, Russia
关键词
phenylaminopropyl silica; stationary phases; LC; linear solvation energy relationships; mobile phase composition; phenols;
D O I
10.1016/S0021-9673(00)00872-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The chromatographic properties of a new stationary phase, phenylaminopropyl silica (PhA-silica), containing phenylaminopropyl residues covalently bonded to the silica surface were studied. The presence of secondary amino groups, phenyl rings and alkyl linkers in the attached molecule makes it especially suitable for the separation of phenols by mixed mode retention mechanism including a combination of hydrogen-bonding, hydrophobic, electrostatic and pi-pi interactions with the stationary phase. The effects of mobile phase pH, ionic strength, nature and concentration of organic modifier on the retention of phenols on PhA-silica were investigated under conditions of reversed-phase HPLC. To elucidate the role of the amino group in the attached molecule in retention of phenols the selectivity of PhA-silica was compared with that obtained for phenylpropyl silica in the framework of a linear solvation energy relationship (LSER) model. The isocratic separation of phenol, and its nine methyl-, chloro- and nitro-substituted derivatives was achieved on a 150x4.6 mm I.D. chromatographic column packed with 7 mum particles of PhA-silica. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:23 / 34
页数:12
相关论文
共 33 条
[1]   HYDROGEN-BONDING .34. THE FACTORS THAT INFLUENCE THE SOLUBILITY OF GASES AND VAPORS IN WATER AT 298-K, AND A NEW METHOD FOR ITS DETERMINATION [J].
ABRAHAM, MH ;
ANDONIANHAFTVAN, J ;
WHITING, GS ;
LEO, A ;
TAFT, RS .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1994, (08) :1777-1791
[2]  
ABRAHAM MH, 1997, U COLL LONDON DATABA
[3]   Test analytes for studies of the molecular mechanism of chromatographic separations by quantitative structure-retention relationships [J].
Al-Haj, MA ;
Kaliszan, R ;
Nasal, A .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :2976-2985
[4]  
Baranowska I, 1998, JPC-J PLANAR CHROMAT, V11, P119
[5]   Influence of solvent effects on retention for a porous polymer sorbent in reversed phase liquid chromatography [J].
Bolliet, D ;
Poole, CF .
CHROMATOGRAPHIA, 1997, 46 (7-8) :381-398
[6]   Conjoint prediction of the retention of neutral and ionic compounds (phenols) in reversed-phase liquid chromatography using the solvation parameter model [J].
Bolliet, D ;
Poole, CF ;
Rosés, M .
ANALYTICA CHIMICA ACTA, 1998, 368 (1-2) :129-140
[7]   Retention of ionizable compounds on HPLC. pH scale in methanol-water and the pK and pH values of buffers [J].
Bosch, E ;
Bou, P ;
Allemann, H ;
Roses, M .
ANALYTICAL CHEMISTRY, 1996, 68 (20) :3651-3657
[8]   LIQUID-CHROMATOGRAPHY ELECTROCHEMISTRY PROCEDURE FOR THE DETERMINATION OF CHLOROPHENOLIC COMPOUNDS IN PULP-MILL EFFLUENTS AND RECEIVING WATERS [J].
BUTLER, ECV ;
DALPONT, G .
JOURNAL OF CHROMATOGRAPHY, 1992, 609 (1-2) :113-123
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF STRUCTURAL ISOMERS USING A CYCLODEXTRIN-POLY(ALLYLAMINE) COATED SILICA COLUMN [J].
CRINI, G ;
TORRI, G ;
LEKCHIRI, Y ;
MARTEL, B ;
JANUS, L ;
MORCELLET, M .
CHROMATOGRAPHIA, 1995, 41 (7-8) :424-430
[10]   SYNTHESIS AND CHARACTERIZATION OF A POLYMERIC FLUOROCARBON-DIAMINE REVERSED-PHASE WEAK ANION-EXCHANGE SILICA HPLC COLUMN PACKING [J].
DANIELSON, ND ;
WANGSA, J ;
SHAMSI, SA .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (13) :2579-2592