Hybrid Repair of an Aortic Arch Aneurysm Rupture in a Redo Sternotomy

被引:2
作者
Nguyen, Tam [1 ]
Claydon, Matthew [1 ]
Marasco, Silvana [1 ]
机构
[1] Alfred Hosp, Dept Vasc Surg, Prahran, Vic 3181, Australia
关键词
Aortic arch; Aneurysm; Rupture; Hybrid repair;
D O I
10.1016/j.hlc.2014.07.068
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose To report a case of operative intervention for an aortic arch aneurysm rupture via a hybrid approach. Methods and Results Ten years after successful open repair of an acute type A aortic dissection a male presented with a rupture of his distal aortic arch aneurysm. A hybrid procedure was carried out which involved debranching of the innominate and left common carotid arteries and stent-graft deployment landing proximally into the ascending aorta and distally into the descending thoracic aorta. Conclusions Ruptured aortic arch aneurysms present a challenging and complex surgical dilemma. Open repair carries high mortality and pure endovascular repair is unfeasible; hence a hybrid repair presents an attractive solution.
引用
收藏
页码:E258 / E260
页数:3
相关论文
共 50 条
  • [11] Hybrid Repair of the Aortic Arch in Patients with Extensive Aortic Disease
    Antoniou, G. A.
    Mireskandari, M.
    Bicknell, C. D.
    Cheshire, N. J. W.
    Gibbs, R. G.
    Hamady, M.
    Wolfe, J. H. N.
    Jenkins, M. P.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2010, 40 (06) : 715 - 721
  • [12] Abrupt rupture of an aortic arch aneurysm into the pulmonary artery
    Nishimura, Yoshiharu
    Okamura, Yoshitaka
    Uchita, Shunji
    Honda, Kentaro
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 36 (01) : 212 - 213
  • [13] Multidetector-row CT imaging of aneurysm rupture of the aortic arch
    Hoshino, Y
    Yamada, I
    Hayashi, S
    Machida, M
    Taya, T
    Ohki, I
    Takahashi, A
    Kurihara, T
    Arai, T
    Miyamoto, Y
    Togo, Y
    Hasegawa, A
    INTERNAL MEDICINE, 2004, 43 (07) : 634 - 636
  • [14] Hybrid procedure to treat aortic arch aneurysm combined with aortic arch coarctation and left internal carotid artery aneurysm (Case Report)
    Zhou, Weimin
    Zhou, Wei
    Qiu, Jiehua
    Zeng, Qingzhong
    JOURNAL OF CARDIOTHORACIC SURGERY, 2014, 9
  • [15] A Technique for Safe Redo Sternotomy in Patients with Aortic Proximity to the Sternum
    Mavroudis, Constantine D.
    Smood, Benjamin
    Grasty, Madison A.
    Fuller, Stephanie
    Desai, Nimesh D.
    WORLD JOURNAL FOR PEDIATRIC AND CONGENITAL HEART SURGERY, 2022, 13 (01) : 89 - 91
  • [16] Hybrid procedure to treat aortic arch aneurysm combined with aortic arch coarctation and left internal carotid artery aneurysm (Case Report)
    Weimin Zhou
    Wei Zhou
    Jiehua Qiu
    Qingzhong Zeng
    Journal of Cardiothoracic Surgery, 9
  • [17] Cardiac tamponade secondary to rupture of a distal aortic arch aneurysm
    Toshihiro Fukui
    Toshihiko Saga
    Hiroshi Kawasaki
    Takuzumi Nishioka
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2002, 50 (5): : 227 - 230
  • [18] Hybrid Open-Endovascular Repair in a Patient With Giant Contained Aortic Aneurysm Rupture
    Lee, David
    Moore, January
    Almerey, Tariq
    Hakaim, Albert
    Farres, Houssam
    VASCULAR AND ENDOVASCULAR SURGERY, 2020, 54 (08) : 725 - 728
  • [19] Re-Rupture 2 Years after Endovascular Aortic Aneurysm Repair Rupture
    Moulakakis, Konstantinos G.
    Tsimpoukis, Andreas
    Katsanos, Konstantinos
    Sintou, Eleni
    Papadoulas, Spyros
    VASCULAR AND ENDOVASCULAR SURGERY, 2023, 57 (07) : 760 - 763
  • [20] Computed tomography angiography of hybrid thoracic endovascular aortic repair of the aortic arch
    Akhtar, Nila J.
    Oderich, Gustavo S.
    Vrtiska, Terri J.
    Williamson, Eric E.
    Araoz, Philip A.
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2013, 11 (05) : 589 - 606