Non-enzymatic and rapid detection of glucose on PVA-CuO thin film using ARDUINO UNO based capacitance measurement unit

被引:12
作者
Dhiman, Tarun Kumar [1 ]
Poddar, Mrinal [1 ]
Lakshmi, G. B. V. S. [1 ]
Kumar, Rahul [1 ,2 ]
Solanki, Pratima R. [1 ]
机构
[1] Jawaharlal Nehru Univ, Special Ctr Nanosci, New Delhi 110067, India
[2] Jawaharlal Nehru Univ, Sch Phys Sci, New Delhi 110067, India
关键词
CuO thin films; Atomic force microscopy; Electron microscopy; Capacitance measurement; Glucose sensing; SENSOR; OXIDE; SENSITIVITY; NANOFIBERS; ELECTRODE; ARRAYS;
D O I
10.1007/s10544-021-00568-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Glucose measurement is one of the essential health monitoring practices for maintaining blood sugar levels. Here, we have fabricated a highly specific capacitive nano-sensor for non-enzymatic glucose detection. Capacitance measurements were carried out on polyvinyl alcohol capped copper oxide (PVA-CuO) thin films on indium tin oxide (ITO) coated glass using ARDUINO UNO. The capacitance study shows a decrease in capacitance with an increase in glucose concentrations. The applicability in real samples was performed by studying the glucose in the presence of fetal bovine serum. Most commonly found interfering agents were used for interference studies, which confirmed the capacitive nano-sensor specificity. The system was further checked for repeatability up to six readings and reproducibility up to 5 chips. The shelf-life study showed stability for four weeks of a chip. These studies indicate that this capacitance-based measurement unit can be used for reliable, rapid, and non-enzymatic detection of glucose in real sample.
引用
收藏
页数:11
相关论文
共 57 条
[1]   The Development of Non-Enzymatic Glucose Biosensors Based on Electrochemically Prepared Polypyrrole-Chitosan-Titanium Dioxide Nanocomposite Films [J].
Al-Mokaram, Ali M. A. Abdul Amir ;
Yahya, Rosiyah ;
Abdi, Mahnaz M. ;
Mahmud, Habibun Nabi Muhammad Ekramul .
NANOMATERIALS, 2017, 7 (06)
[2]   A non-enzymatic glucose sensor based on a CoNi2Se4/rGO nanocomposite with ultrahigh sensitivity at low working potential [J].
Amin, Bahareh Golrokh ;
Masud, Jahangir ;
Nath, Manashi .
JOURNAL OF MATERIALS CHEMISTRY B, 2019, 7 (14) :2338-2348
[3]   Co-Ni layered double hydroxides wrapped on leaf-shaped copper oxide hybrids for non-enzymatic detection of glucose [J].
An, Siying ;
Shang, Ningzhao ;
Chen, Boying ;
Kang, Yujie ;
Su, Ming ;
Wang, Chun ;
Zhang, Yufan .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2021, 592 :205-214
[4]  
Berggren C, 2001, ELECTROANAL, V13, P173, DOI 10.1002/1521-4109(200103)13:3<173::AID-ELAN173>3.0.CO
[5]  
2-B
[6]   Significant enhancement of optical absorption through nano-structuring of copper based oxide semiconductors: possible future materials for solar energy applications [J].
Bhaumik, Anagh ;
Shearin, Austin M. ;
Patel, Rishi ;
Ghosh, Kartik .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2014, 16 (22) :11054-11066
[7]  
Block C.D., 2008, REV CURRENT EVIDENCE
[8]  
Buda RA, 2014, 2014 IEEE CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), P964, DOI 10.1109/IECBES.2014.7047655
[9]   Capacitive detection of glucose using molecularly imprinted polymers [J].
Cheng, ZL ;
Wang, EK ;
Yang, XR .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (03) :179-185
[10]  
CLARK LC, 1988, METHOD ENZYMOL, V137, P68