Impact of a motion correction algorithm on quality and diagnostic utility in unselected patients undergoing coronary CT angiography

被引:11
作者
Sheta, Hussam Mahmoud [1 ]
Egstrup, Kenneth [1 ]
Husic, Mirza [1 ]
Heinsen, Laurits Juhl [1 ]
Lambrechtsen, Jess [1 ]
机构
[1] OUH Svendborg Sygehus, Med Forskningsafdeling, Inst Reg Hlth Res, Valdemarsgade 53, DK-5700 Svendborg, Denmark
关键词
Coronary computed tomography; Motion correction algorithm; Motion artifacts; Diagnostic utility; Snapshot Freeze; SPIRAL COMPUTED-TOMOGRAPHY; HEART-RATE-VARIABILITY; IMAGE QUALITY; ROW CT; ARTERY-DISEASE; RECONSTRUCTION; ACCURACY; VISUALIZATION; EXPERIENCE; RESOLUTION;
D O I
10.1016/j.clinimag.2015.10.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aims: The aims of the study were to investigate the diagnostic utility of motion correction reconstruction algorithm Snapshot Freeze (SSF) compared to the standard reconstruction algorithm (STD) in coronary computed tomography angiography (CCTA) images where a prescan heart-rate-lowering protocol is fully integrated. Methods: CCTA was performed in 140 patients. Two independent blinded readers made image evaluation of the SSF and STD images. Results: SSF reduced the motion artifacts (30% vs. 41%; P<.05) and improved the image quality ("excellent' images: 52% vs. 42%; P=.022), but did not influence diagnostic utility ("nondiagnostic" images: 10% vs. 14%; P=.104). Conclusion: The use of the SSF algorithm reduced the presence of motion artifacts and improved image quality, but did not influence the diagnostic utility. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:217 / 221
页数:5
相关论文
共 27 条
[1]   Comparison of image quality in contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography [J].
Achenbach, S ;
Giesler, T ;
Ropers, D ;
Ulzheimer, S ;
Anders, K ;
Wenkel, E ;
Pohle, K ;
Kachelriess, M ;
Derlien, H ;
Kalender, WA ;
Daniel, WG ;
Bautz, W ;
Baum, U .
INVESTIGATIVE RADIOLOGY, 2003, 38 (02) :119-128
[2]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[3]   Enhanced temporal resolution at cardiac CT with a novel CT image reconstruction algorithm: Initial patient experience [J].
Apfaltrer, Paul ;
Schoendube, Harald ;
Schoepf, U. Joseph ;
Allmendinger, Thomas ;
Tricarico, Francesco ;
Schindler, Andreas ;
Vogt, Sebastian ;
Sunnegardh, Johan ;
Stierstorfer, Karl ;
Henzler, Thomas ;
Fink, Christian ;
Bruder, Herbert ;
Flohr, Thomas G. ;
Ebersberger, Ullrich .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (02) :270-274
[4]   Non-invasive detection of coronary artery disease in patients with left bundle branch block using 64-slice computed tomography [J].
Ghostine, Said ;
Caussin, Christophe ;
Daoud, Beatrice ;
Habis, Michel ;
Perrier, Eric ;
Pesenti-Rossi, David ;
Sigal-Cinqualbre, Anne ;
Angel, Claude-Yves ;
Lancelin, Bernard ;
Capderou, Andre ;
Paul, Jean-Francois .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (10) :1929-1934
[5]   Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection [J].
Giesler, T ;
Baum, U ;
Ropers, D ;
Ulzheimer, S ;
Wenkel, E ;
Mennicke, M ;
Bautz, W ;
Kalender, WA ;
Daniel, WG ;
Achenbach, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (04) :911-916
[6]   Non-invasive coronary computed tomographic angiography for patients with suspected coronary artery disease:: the Coronary Angiography by Computed Tomography with the Use of a Submillimeter resolution (CACTUS) trial [J].
Hausleiter, Joerg ;
Meyer, Tanja ;
Hadamitzky, Martin ;
Zankl, Maria ;
Gerein, Pia ;
Doerrler, Katharina ;
Kastrati, Adnan ;
Martinoff, Stefan ;
Schoemig, Albert .
EUROPEAN HEART JOURNAL, 2007, 28 (24) :3034-3041
[7]   Multi-detector row CT coronary angiography: Influence of reconstruction technique and heart rate on image quality [J].
Herzog, C ;
Arning-Erb, M ;
Zangos, S ;
Eichler, K ;
Hammerstingl, R ;
Dogan, S ;
Ackermann, H ;
Vogl, TJ .
RADIOLOGY, 2006, 238 (01) :75-86
[8]   Noninvasive coronary angiography with 16-detector row CT: Effect of heart rate [J].
Hoffmann, MHK ;
Shi, HS ;
Manzke, R ;
Schmid, FT ;
De Vries, L ;
Grass, M ;
Brambs, HR ;
Aschoff, AJ .
RADIOLOGY, 2005, 234 (01) :86-97
[9]   Relationship between Heart Rate and Optimal Reconstruction Phase in Dual-source CT Coronary Angiography [J].
Horii, Yosuke ;
Yoshimura, Norihiko ;
Hori, Yoshiro ;
Takano, Toru ;
Inagawa, Shoichi ;
Akazawa, Kohei ;
Aoyama, Hidefumi .
ACADEMIC RADIOLOGY, 2011, 18 (06) :726-730
[10]   Coronary artery motion and cardiac phases: Dependency on heart rate - Implications for CT image reconstruction [J].
Husmann, Lars ;
Leschka, Sebastian ;
Desbiolles, Lotus ;
Schepis, Tiziano ;
Gaemperli, Oliver ;
Seifert, Burkhardt ;
Cattin, Philippe ;
Frauenfelder, Thomas ;
Flohr, Thomas G. ;
Marincek, Borut ;
Kaufmann, Philipp A. ;
Alkadhi, Hatem .
RADIOLOGY, 2007, 245 (02) :567-576