Occupational exposure from external radiation used in medical practices in Pakistan by film badge dosimetry

被引:26
作者
Jabeen, A. [1 ]
Munir, M. [1 ]
Khalil, A. [1 ]
Masood, M. [1 ]
Akhter, P. [1 ]
机构
[1] Pakistan Inst Nucl Sci & Technol PINSTECH, Directorate Syst & Serv, Div Hlth Phys, Radiat Dosimetry Grp, Islamabad, Pakistan
关键词
D O I
10.1093/rpd/ncq134
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Occupational exposure data of workers due to external sources of radiation in various medical practices such as nuclear medicine (NM), radiotherapy and diagnostic radiology (DR) in Pakistan were collected and analysed. Whole-body doses of workers were measured by film badge dosimetry technique during 2003-2007. Annual average effective dose in NM, radiotherapy and DR varied in the range of 1.39-1.80, 1.05-1.45 and 1.22-1.71 mSv, respectively, during 2003-2007. These values are quite low and well below the annual limit of 20 mSv averaged over a period of 5 consecutive years. Nobody received the radiation dose > 50 mSv in any single year over a period of 5 consecutive years; therefore, no overexposure case has been detected. Decreasing trend of annual average dose values in aforementioned categories of work during 2003-2007 indicates the improvement of radiation protection status in medical field in Pakistan.