A Study of Calibration Method for Lenticular Glasses-free 3D Display Using Light Transport Matrix

被引:0
|
作者
Fukatsu, Asuka [1 ]
Nishihara, Isao [1 ]
Nakata, Takayuki [1 ]
机构
[1] Toyama Prefectural Univ, Dept Informat Syst Engn, Toyama, Japan
来源
INTERNATIONAL WORKSHOP ON ADVANCED IMAGING TECHNOLOGY (IWAIT) 2022 | 2022年 / 12177卷
关键词
Calibration; Autostereoscopic display; 3D display; Lenticular lens;
D O I
10.1117/12.2626121
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In recent years, glasses-free 3D displays are expected to play an active role in various fields and have been studied. Lenticular glasses-free 3D displays are calibrated based on a one-to-one correspondence between the ray vector emitted from the display and the ray vector observed by the camera. However, in the real world, light emitted from a single pixel on the display affects multiple pixels in the camera, so it is necessary to consider a one-to-many correspondence. In this study, we investigate a calibration method that takes into account the spread of light generated in the real environment by using the light transport matrix that shows the correspondence between the display and the camera. We obtained the light transport matrix and conducted an experiment to generate a display image calibrated to the camera position. The generated image was drawn on the display and observed using the same camera, and it was confirmed that the image was calibrated to the camera position. In the future, we aim to expand the parallax by increasing the number of cameras.
引用
收藏
页数:5
相关论文
共 30 条
  • [11] A prototype system for 3D measurement using flexible calibration method
    Fukuda, Masanori
    Miyasaka, Takeo
    Araki, Kazuo
    THREE-DIMENSIONAL IMAGE CAPTURE AND APPLICATIONS VII, 2006, 6056
  • [12] Hybrid calibration method for improving 3D measurement accuracy of structured light systems
    Marrugo, Andres G.
    Vargas, Raul
    Zhang, Song
    Romero, Lenny A.
    INTERFEROMETRY XX, 2020, 11490
  • [13] A simple calibration method for structured light-based 3D profile measurement
    Xu, Jing
    Douet, Jules
    Zhao, Jianguo
    Song, Libin
    Chen, Ken
    OPTICS AND LASER TECHNOLOGY, 2013, 48 : 187 - 193
  • [14] Dynamic head tracked 3D display using fast spatial light modulator
    Zhang, Lei
    Surman, Phil
    Zheng, Yuanjin
    2017 OPTO-ELECTRONICS AND COMMUNICATIONS CONFERENCE (OECC) AND PHOTONICS GLOBAL CONFERENCE (PGC), 2017,
  • [15] Polynomial-fitting Based Calibration for an Active 3D Sensing System Using Dynamic Light Section Method
    Ikura, Mikihiro
    Pathak, Sarthak
    Yamashita, Atsushi
    Asama, Hajime
    Komuro, Takashi
    Shimizu, Tsuyoshi
    FIFTEENTH INTERNATIONAL CONFERENCE ON QUALITY CONTROL BY ARTIFICIAL VISION, 2021, 11794
  • [16] Ray-space based 3D image input method for a color 3D display using a method of the reconstruction of parallax rays
    Takahashi, H
    Yamada, K
    Shimizu, E
    THREE-DIMENSIONAL TV, VIDEO AND DISPLAY, 2002, 4864 : 72 - 79
  • [17] Calibration Method of 3D Body Measurement System Using Stripe Grating Projection
    Huang, Xiuxiang
    Tan, Qing
    Xia, Yimin
    Liu, Zeyuan
    Cai, Lei
    FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY II, PTS 1 AND 2, 2012, 503-504 : 1265 - +
  • [18] Extrinsic Calibration between a 3D Laser Scanner and a Camera using PCA method
    Park, Sang Un
    Chung, Myung Jin
    2012 9TH INTERNATIONAL CONFERENCE ON UBIQUITOUS ROBOTS AND AMBIENT INTELLIGENCE (URAL), 2012, : 527 - 528
  • [19] A high accuracy and robustness 3D imaging method for line structured light single plane calibration
    Chen X.
    Zhang Z.
    Yang X.
    Xu J.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2021, 42 (10): : 179 - 187
  • [20] A Calibration Method of 3D Shape Measurement System Using 3D Scanner, Turn-table and Arm-robot
    Ukida, Hiroyuki
    Sasao, Tomoyo
    Terada, Kenji
    Yoshida, Atsuya
    2019 58TH ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS OF JAPAN (SICE), 2019, : 136 - 141