Evaluation of PM10, CO2, airborne bacteria, TVOCs, and formaldehyde in facilities for susceptible populations in South Korea

被引:36
作者
Hwang, Sung Ho [1 ]
Roh, Jaehoon [2 ,3 ,4 ,5 ]
Park, Wha Me [2 ,3 ]
机构
[1] Natl Canc Ctr, Natl Canc Control Inst, 323 Ilsan Ro, Goyang Si, Gyeonggi Do, South Korea
[2] Yonsei Univ, Coll Med, Inst Occupat Hlth, Seoul, South Korea
[3] Yonsei Univ, Grad Sch Publ Hlth, Seoul, South Korea
[4] Yonsei Univ, Coll Med, Dept Prevent Med, Seoul, South Korea
[5] Inchen Workers Hlth Ctr, Incheon, South Korea
基金
新加坡国家研究基金会;
关键词
Airborne bacteria; Carbon dioxide; Formaldehyde; PM10; Susceptible population; Total volatile organic compounds; INDOOR AIR-QUALITY; PARTICULATE MATTER PM10; METROPOLITAN SUBWAY STATIONS; VOLATILE ORGANIC-COMPOUNDS; INFANT-DEATH-SYNDROME; ELEMENTARY-SCHOOLS; RELATIVE-HUMIDITY; CULTURABLE FUNGI; NITROGEN-DIOXIDE; RISK-ASSESSMENT;
D O I
10.1016/j.envpol.2018.07.013
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Poor indoor air quality can have adverse effects on human health, especially in susceptible populations: however, few studies have measured multiple pollutants in facilities for susceptible populations at a national scale in South Korea. Therefore, we measured the concentrations of indoor pollutants (fine particulate matter (PM10), CO2, airborne bacteria (AB), total volatile organic compounds (TVOCs), and formaldehyde) to determine their possible relation to other indoor environmental factors and characteristics of facilities with susceptible populations, such as hospitals, geriatric hospitals, elderly care facilities, and postnatal care centers throughout South Korea. Indoor pollutants were sampled at 82 indoor facilities, including 62 facilities for susceptible populations. Spearman's correlation, Kruskal Wallis, and Mann-Whitney analyses were used to examine the relationship among and differences between pollutants at indoor facilities and indoor/outdoor differences in PM10 concentration. There were significant correlations between indoor temperature and AB concentration (r = 0.37, p < 0.01), TVOCs, and formaldehyde (r = 0.264, p < 0.01). Indoor PM10 concentrations were higher than outdoor concentrations at all facilities for susceptible populations (p < 0.01). CO2 might be a good indicator for predicting indoor pollutants when categorized into two levels (<= 750 ppm and >750 ppm). The hazard quotient of formaldehyde was higher than the acceptable level of 1 for children under the age of eight in postnatal care centers, indicative of unsafe levels. Therefore, more depth study for exposure characteristics of formaldehyde and indoor air quality (IAQ) in postnatal care facilities as a national scale is needed for finding the children exposure levels. (C) 2018 Published by Elsevier Ltd.
引用
收藏
页码:700 / 708
页数:9
相关论文
共 57 条
[1]   A review of standards and guidelines set by international bodies for the parameters of indoor air quality [J].
Abdul-Wahab, Sabah Ahmed ;
En, Stephen Chin Fah ;
Elkamel, Ali ;
Ahmadi, Lena ;
Yetilmezsoy, Kaan .
ATMOSPHERIC POLLUTION RESEARCH, 2015, 6 (05) :751-767
[2]  
[Anonymous], 1999, BIOAER ASS CONTR
[3]  
[Anonymous], 1998, NIOSH MAN AN METH
[4]  
[Anonymous], HOUS HLTH ID PRIOR M
[5]  
[Anonymous], 2000, PREVENTING MANAGING, P1, DOI [10.1007/BF02986808, DOI 10.1007/BF02986808]
[6]  
[Anonymous], 2013, HLTH EFF PART MATT
[7]   Indoor NO2 air pollution and lung function of professional cooks [J].
Arbex, M. A. ;
Martins, L. C. ;
Pereira, L. A. A. ;
Negrini, F. ;
Cardoso, A. A. ;
Melchert, W. R. ;
Arbex, R. F. ;
Saldiva, P. H. N. ;
Zanobetti, A. ;
Braga, A. L. F. .
BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2007, 40 (04) :527-534
[8]   Children's response to air pollutants [J].
Bateson, Thomas F. ;
Schwartz, Joel .
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART A-CURRENT ISSUES, 2008, 71 (03) :238-243
[9]   Children's exposure to indoor air in urban nurseries - Part II: Gaseous pollutants' assessment [J].
Branco, P. T. B. S. ;
Nunes, R. A. O. ;
Alvim-Ferraz, M. C. M. ;
Martins, F. G. ;
Souse, S. I. V. .
ENVIRONMENTAL RESEARCH, 2015, 142 :662-670
[10]   Measurement of nucleation and soot mode particle emission from a diesel passenger car in real world and laboratory in situ dilution [J].
Casati, Roberto ;
Scheer, Volker ;
Vogt, Rainer ;
Benter, Thorsten .
ATMOSPHERIC ENVIRONMENT, 2007, 41 (10) :2125-2135