Dose-Toxicity Relationship of Gadoxetate Disodium and Transient Severe Respiratory Motion Artifact

被引:68
|
作者
Davenport, Matthew S. [1 ]
Bashir, Mustafa R. [2 ]
Pietryga, Jason A. [2 ]
Weber, Joseph T. [3 ]
Khalatbari, Shokoufeh [4 ]
Hussain, Hero K. [1 ]
机构
[1] Univ Michigan Hlth Syst, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Duke Univ, Med Ctr, Dept Radiol, Div Abdominal Imaging, Durham, NC 27710 USA
[3] Pulm & Crit Care Associates SC, Cudahy, WI USA
[4] Univ Michigan, Michigan Inst Clin & Hlth Res, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
artifact; complication; gadoxetate disodium; respiratory motion; OBSTRUCTIVE PULMONARY-DISEASE; GD-EOB-DTPA; HEPATOCELLULAR-CARCINOMA; DYNAMIC HYPERINFLATION; PROTOCOL OPTIMIZATION; LIVER-TRANSPLANTATION; LESION APPEARANCE; CIRRHOTIC LIVER; ENHANCED MRI; EXACERBATIONS;
D O I
10.2214/AJR.13.11587
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this article is to determine whether there is a dose-toxicity relationship between gadoxetate disodium and transient severe respiratory motion artifact. MATERIALS AND METHODS. Gadoxetate disodium-enhanced MRI studies (559 studies of 559 patients) using a fixed 20-mL (2 mL/s; n = 112) or 10-mL (1-2 mL/s; n = 447) volume at two health systems were included (dose range, 0.05-0.42 mL/kg; mean, 0.15 mL/ kg; above-label dosing, 479 [86%]). Each dynamic phase was assigned a respiratory motion score from 1 (none) to 5 (nondiagnostic). Examinations with an unenhanced score of 1-2, arterial score of 4-5, and venous or late-dynamic scores of 1-3 were labeled as transient severe respiratory motion artifact. Stepwise multivariate logistic regression was performed. RESULTS. The overall incidence of transient severe respiratory motion artifact was 12% (67/559; site 1, 15% [35/232]; site 2, 9.8% [32/327]). The administered volume of contrast material had a statistically significant effect (20 mL, 20% [22/112] vs 10 mL, 10%, [45/447]; multivariate p = 0.01; odds ratio, 2.1 [20 vs 10 mL]; 95% CI, 1.2-3.7). There was no dose-toxicity relationship for dose-by-weight (p = 0.61 [multivariate]) or above-label dosing (p = 0.88 [univariate]; 13% [10/80] rate for at-or below-label dosing vs 12% [57/479] rate for above-label dosing). Chronic obstructive pulmonary disease was the only non-doserelated predictor in the multivariate model (p < 0.0001; OR, 5.1 [95% CI, 2.5-11.5]; 39% [12/31] vs 10% [55/528]). CONCLUSION. Gadoxetate disodium-associated transient severe respiratory motion artifact is significantly more common after 20-mL administration (2 mL/s) and occurs significantly more often in patients with chronic obstructive pulmonary disease. The volumerelated effect suggests a nonallergiclike mechanism.
引用
收藏
页码:796 / 802
页数:7
相关论文
共 33 条
  • [21] Transient respiratory motion artifacts in multiple arterial phases on abdominal dynamic magnetic resonance imaging: a comparison using gadoxetate disodium and gadobutrol
    Tanabe, Masahiro
    Higashi, Mayumi
    Iida, Etsushi
    Onoda, Hideko
    Ihara, Kenichiro
    Ariyoshi, Shoko
    Kameda, Fumi
    Miyoshi, Keisuke
    Furukawa, Matakazu
    Okada, Munemasa
    Ito, Katsuyoshi
    JAPANESE JOURNAL OF RADIOLOGY, 2021, 39 (02) : 178 - 185
  • [22] Transient respiratory motion artifacts in multiple arterial phases on abdominal dynamic magnetic resonance imaging: a comparison using gadoxetate disodium and gadobutrol
    Masahiro Tanabe
    Mayumi Higashi
    Etsushi Iida
    Hideko Onoda
    Kenichiro Ihara
    Shoko Ariyoshi
    Fumi Kameda
    Keisuke Miyoshi
    Matakazu Furukawa
    Munemasa Okada
    Katsuyoshi Ito
    Japanese Journal of Radiology, 2021, 39 : 178 - 185
  • [23] Comparison of transient severe motion in gadoxetate disodium and gadopentetate dimeglumine-enhanced MRI: effect of modified breath-holding method
    Ji Soo Song
    Eun Jung Choi
    Eun Hae Park
    Ju-Hyung Lee
    European Radiology, 2018, 28 : 1132 - 1139
  • [24] CAIPIRINHA-Dixon-TWIST (CDT)-VIBE MR imaging of the liver at 3.0T with gadoxetate disodium: a solution for transient arterial-phase respiratory motion-related artifacts?
    Gruber, Leonhard
    Rainer, Vera
    Plaikner, Michaela
    Kremser, Christian
    Jaschke, Werner
    Henninger, Benjamin
    EUROPEAN RADIOLOGY, 2018, 28 (05) : 2013 - 2021
  • [25] Transient severe motion during arterial phase in patients with Gadoxetic acid administration: Can a five hepatic arterial subphases technique mitigate the artifact?
    Xiao, Yu-Dong
    Ma, Cong
    Liu, Jun
    Li, Hua-Bing
    Zhou, Shun-Ke
    Zhang, Zi-Shu
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2018, 15 (03) : 3133 - 3139
  • [26] Respiratory motion in children and young adults undergoing liver magnetic resonance imaging with intravenous gadoxetate disodium contrast material
    Leah A. Gilligan
    Andrew T. Trout
    Christopher G. Anton
    Andrew H. Schapiro
    Alexander J. Towbin
    Jonathan R. Dillman
    Pediatric Radiology, 2019, 49 : 1171 - 1176
  • [27] Influence of age on gadoxetic acid disodium-induced transient respiratory motion artifacts in pediatric liver MRI
    Hojreh, Azadeh
    Ba-Ssalamah, Ahmed
    Lang, Christian
    Poetter-Lang, Sarah
    Huber, Wolf-Dietrich
    Tamandl, Dietmar
    PLOS ONE, 2022, 17 (03):
  • [28] Relationship between the degree of abdominal wall movement and the image quality of contrast-enhanced MRI: semi-quantitative study especially focused on the occurrence of transient severe motion artifact
    Ikeno, Hiroshi
    Kobayashi, Satoshi
    Kozaka, Kazuto
    Ogi, Takahiro
    Inoue, Dai
    Yoneda, Norihide
    Yoshida, Kotaro
    Ohno, Naoki
    Gabata, Toshifumi
    Kitao, Azusa
    JAPANESE JOURNAL OF RADIOLOGY, 2020, 38 (02) : 165 - 177
  • [29] Transient arterial phase respiratory motion-related artifact in MR imaging of the liver: an analysis of four different gadolinium-based contrast agents
    Shah, Mansi R.
    Flusberg, Milana
    Paroder, Viktoriya
    Rozenblit, Alla M.
    Chemyak, Victoria
    CLINICAL IMAGING, 2017, 41 : 23 - 27
  • [30] Relationship between the degree of abdominal wall movement and the image quality of contrast-enhanced MRI: semi-quantitative study especially focused on the occurrence of transient severe motion artifact
    Hiroshi Ikeno
    Satoshi Kobayashi
    Kazuto Kozaka
    Takahiro Ogi
    Dai Inoue
    Norihide Yoneda
    Kotaro Yoshida
    Naoki Ohno
    Toshifumi Gabata
    Azusa Kitao
    Japanese Journal of Radiology, 2020, 38 : 165 - 177