Dose-Toxicity Relationship of Gadoxetate Disodium and Transient Severe Respiratory Motion Artifact

被引:68
|
作者
Davenport, Matthew S. [1 ]
Bashir, Mustafa R. [2 ]
Pietryga, Jason A. [2 ]
Weber, Joseph T. [3 ]
Khalatbari, Shokoufeh [4 ]
Hussain, Hero K. [1 ]
机构
[1] Univ Michigan Hlth Syst, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Duke Univ, Med Ctr, Dept Radiol, Div Abdominal Imaging, Durham, NC 27710 USA
[3] Pulm & Crit Care Associates SC, Cudahy, WI USA
[4] Univ Michigan, Michigan Inst Clin & Hlth Res, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
artifact; complication; gadoxetate disodium; respiratory motion; OBSTRUCTIVE PULMONARY-DISEASE; GD-EOB-DTPA; HEPATOCELLULAR-CARCINOMA; DYNAMIC HYPERINFLATION; PROTOCOL OPTIMIZATION; LIVER-TRANSPLANTATION; LESION APPEARANCE; CIRRHOTIC LIVER; ENHANCED MRI; EXACERBATIONS;
D O I
10.2214/AJR.13.11587
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this article is to determine whether there is a dose-toxicity relationship between gadoxetate disodium and transient severe respiratory motion artifact. MATERIALS AND METHODS. Gadoxetate disodium-enhanced MRI studies (559 studies of 559 patients) using a fixed 20-mL (2 mL/s; n = 112) or 10-mL (1-2 mL/s; n = 447) volume at two health systems were included (dose range, 0.05-0.42 mL/kg; mean, 0.15 mL/ kg; above-label dosing, 479 [86%]). Each dynamic phase was assigned a respiratory motion score from 1 (none) to 5 (nondiagnostic). Examinations with an unenhanced score of 1-2, arterial score of 4-5, and venous or late-dynamic scores of 1-3 were labeled as transient severe respiratory motion artifact. Stepwise multivariate logistic regression was performed. RESULTS. The overall incidence of transient severe respiratory motion artifact was 12% (67/559; site 1, 15% [35/232]; site 2, 9.8% [32/327]). The administered volume of contrast material had a statistically significant effect (20 mL, 20% [22/112] vs 10 mL, 10%, [45/447]; multivariate p = 0.01; odds ratio, 2.1 [20 vs 10 mL]; 95% CI, 1.2-3.7). There was no dose-toxicity relationship for dose-by-weight (p = 0.61 [multivariate]) or above-label dosing (p = 0.88 [univariate]; 13% [10/80] rate for at-or below-label dosing vs 12% [57/479] rate for above-label dosing). Chronic obstructive pulmonary disease was the only non-doserelated predictor in the multivariate model (p < 0.0001; OR, 5.1 [95% CI, 2.5-11.5]; 39% [12/31] vs 10% [55/528]). CONCLUSION. Gadoxetate disodium-associated transient severe respiratory motion artifact is significantly more common after 20-mL administration (2 mL/s) and occurs significantly more often in patients with chronic obstructive pulmonary disease. The volumerelated effect suggests a nonallergiclike mechanism.
引用
收藏
页码:796 / 802
页数:7
相关论文
共 33 条
  • [1] Transient Respiratory Motion Artifact During Arterial Phase MRI With Gadoxetate Disodium: Risk Factor Analyses
    Kim, So Yeon
    Park, Seong Ho
    Wu, En-Haw
    Wang, Z. Jane
    Hope, Thomas A.
    Chang, Wei-Chou
    Yeh, Benjamin M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (06) : 1220 - 1227
  • [2] Transient Severe Respiratory Motion Artifacts After Application of Gadoxetate Disodium: What We Currently Know
    Well, Lennart
    Weinrich, Julius Matthias
    Adam, Gerhard
    Bannas, Peter
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2018, 190 (01): : 20 - 30
  • [3] Fully automatic quantification of transient severe respiratory motion artifact of gadoxetate disodium-enhanced MRI during arterial phase
    Jang, Jinseong
    Chung, Yong Eun
    Kim, Sungwon
    Hwang, Dosik
    MEDICAL PHYSICS, 2022, 49 (11) : 7247 - 7261
  • [4] Respiratory Motion Artifact Affecting Hepatic Arterial Phase MR Imaging with Gadoxetate Disodium Is More Common in Patients with a Prior Episode of Arterial Phase Motion Associated with Gadoxetate Disodium
    Bashir, Mustafa R.
    Castelli, Patricia
    Davenport, Matthew S.
    Larson, Douglas
    Marin, Daniele
    Hussain, Hero K.
    Jaffe, Tracy A.
    RADIOLOGY, 2015, 274 (01) : 141 - 148
  • [5] Transient Severe Motion Artifact Related to Gadoxetate Disodium-Enhanced Liver MRI: Frequency and Risk Evaluation at a German Institution
    Well, Lennart
    Rausch, Vanessa Hanna
    Adam, Gerhard
    Henes, Frank Oliver
    Bannas, Peter
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2017, 189 (07): : 651 - 660
  • [6] Rate of gadoxetate disodium (Eovist®) induced transient respiratory motion in children and young adults
    Lanier, Hunter
    Wallace, Andrew
    Khanna, Geetika
    ABDOMINAL RADIOLOGY, 2020, 45 (01) : 101 - 106
  • [7] Respiratory Motion Artifact Affecting Hepatic Arterial Phase Imaging with Gadoxetate Disodium: Examination Recovery with a Multiple Arterial Phase Acquisition
    Pietryga, Jason A.
    Burke, Lauren M. B.
    Marin, Daniele
    Jaffe, Tracy A.
    Bashir, Mustafa R.
    RADIOLOGY, 2014, 271 (02) : 426 - 434
  • [8] Characterization of Severe Arterial Phase Respiratory Motion Artifact on Gadoxetate Disodium-Enhanced MRI - Assessment of Interrater Agreement and Reliability
    Ringe, Kristina Imeen
    Luetkens, Julian A.
    Fimmers, Rolf
    Hammerstingl, Renate Maria
    Layer, Guenter
    Maurer, Martin H.
    Naehle, Claas Philip
    Michalik, Sabine
    Reimer, Peter
    Schraml, Christina
    Schreyer, Andreas G.
    Stumpp, Patrick
    Vogl, Thomas J.
    Wacker, Frank K.
    Willinek, Winfried
    Kukuk, Guido Mattias
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2018, 190 (04): : 341 - 347
  • [9] Rate of gadoxetate disodium (Eovist®) induced transient respiratory motion in children and young adults
    Hunter Lanier
    Andrew Wallace
    Geetika Khanna
    Abdominal Radiology, 2020, 45 : 101 - 106
  • [10] Transient severe motion in the arterial phase during gadoxetate disodium-enhanced MR imaging: evaluation of patients with multiple MR examinations
    Im, Won Hyeong
    Song, Ji Soo
    Park, Eun Hae
    Kwak, Hyo Sung
    ABDOMINAL RADIOLOGY, 2017, 42 (10) : 2393 - 2401