Carotid Arterial Wall MRI at 3T Using 3D Variable-Flip-Angle Turbo Spin-Echo (TSE) with Flow-Sensitive Dephasing (FSD)

被引:127
|
作者
Fan, Zhaoyang [1 ,2 ]
Zhang, Zhuoli [1 ]
Chung, Yiu-Cho [3 ]
Weale, Peter [3 ]
Zuehlsdorff, Sven [3 ]
Carr, James [1 ]
Li, Debiao [1 ,2 ]
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Evanston, IL 60208 USA
[3] Siemens Med Solut USA Inc, Chicago, IL USA
关键词
carotid artery; magnetic resonance imaging; atherosclerosis; 3D SPACE; black-blood; RAPID EXTENDED COVERAGE; BLACK-BLOOD MRI; ATHEROSCLEROTIC PLAQUE; MAGNETIC-RESONANCE; 1.5; T; ARTIFACTS; ANGIOGRAPHY; SEQUENCES; CONTRAST; LESIONS;
D O I
10.1002/jmri.22058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the effectiveness of flow-sensitive dephasing (FSD) magnetization preparation in improving blood signal suppression of three-dimensional (3D) turbo spin-echo (TSE) sequence (SPACE) for isotropic high-spatial-resolution carotid arterial wall imaging at 3T. Materials and Methods: The FSD-prepared SPACE sequence (FSD-SPACE) was implemented by adding two identical FSD gradient pulses right before and after the first refocusing 180 degrees-pulse of the SPACE sequence in all three orthogonal directions. Nine healthy volunteers were imaged at 3T with SPACE, FSD-SPACE, and multislice T2-weighted 2D TSE coupled with saturation band (SB-TSE). Apparent carotid wall-lumen contrast-to-noise ratio (aCNR(w-1)) and apparent lumen area (aLA) at the locations with residual-blood (rb) signal shown on SPACE images were compared between SPACE and FSD-SPACE. Carotid aCNR(w-1) and lumen (LA) and wall area (WA) measured from FSD-SPACE were compared to those measured from SB-TSE. Results: Plaque-mimicking flow artifacts identified in seven carotids on SPACE images were eliminated on FSD-SPACE images. The FSD preparation resulted in slightly reduced aCNR(w-1) (P = 0.025), but significantly improved aCNR between the wall and rb regions (P < 0.001) and larger aLA (P < 0.001). Compared to SB-TSE, FSD-SPACE offered comparable aCNR(w-1) with much higher spatial resolution, shorter imaging time, and larger artery coverage. The LA and WA measurements from the two techniques were in good agreement based on intraclasss correlation coefficient (0.988 and 0.949, respectively; P < 0.001) and Bland-Altman analyses. Conclusion: FSD-SPACE is a time-efficient 3D imaging technique for carotid arterial wall with superior spatial resolution and blood signal suppression.
引用
收藏
页码:645 / 654
页数:10
相关论文
共 30 条
  • [21] Improved Imaging of Cochlear Nerve Hypoplasia Using a 3-Tesla Variable Flip-Angle Turbo Spin-Echo Sequence and a 7-cm Surface Coil
    Giesemann, Anja M.
    Raab, Peter
    Lyutenski, Stefan
    Dettmer, Sabine
    Bueltmann, Eva
    Froemke, Cornelia
    Lenarz, Thomas
    Lanfermann, Heinrich
    Goetz, Friedrich
    LARYNGOSCOPE, 2014, 124 (03) : 751 - 754
  • [22] SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences
    Jung, Joon-Yong
    Jee, Won-Hee
    Park, Michael Yong
    Lee, So-Yeon
    Kim, Yang-Soo
    EUROPEAN RADIOLOGY, 2013, 23 (02) : 487 - 495
  • [23] High-resolution 3D arteriography of chronic total peripheral occlusions using a T1-W turbo spin-echo sequence with inner-volume Imaging
    Sampath, Smita
    Raval, Amish N.
    Lederman, Robert J.
    McVeigh, Elliot R.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (01) : 40 - 49
  • [24] Whole-Brain Intracranial Vessel Wall Imaging at 3 Tesla Using Cerebrospinal Fluid-Attenuated T1-Weighted 3D Turbo Spin Echo
    Fan, Zhaoyang
    Yang, Qi
    Deng, Zixin
    Li, Yuxia
    Bi, Xiaoming
    Song, Shlee
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) : 1142 - 1150
  • [25] Semiautomated Segmentation and Volume Measurements of Cervical Carotid High-Signal Plaques Using 3D Turbo Spin-Echo T1-Weighted Black-Blood Vessel Wall Imaging: A Preliminary Study
    Inoue, Katsuhiro
    Nakayama, Ryohei
    Isoshima, Shiho
    Takase, Shinichi
    Yamahata, Tsunehiro
    Umino, Maki
    Maeda, Masayuki
    Sakuma, Hajime
    DIAGNOSTICS, 2022, 12 (04)
  • [26] Assessment of knee cartilage using accelerated 3 T MRI: Evaluation of an isotropic 3D fast spin-echo sequence (CUBE) with compressed sensing technique
    Willaume, Thibault
    Ehlinger, Matthieu
    Favreau, Henri
    Weingertner, Noelle
    Zorn, Pierre-Emmanuel
    Dillenseger, Jean-Philippe
    Koch, Guillaume
    Velten, Michel
    Bierry, Guillaume
    MAGNETIC RESONANCE IMAGING, 2025, 117
  • [27] Value of three-dimensional T2-weighted turbo spin-echo imaging with tissue-specific variable refocusing flip angle for 3-T magnetic resonance imaging of prostate cancer: comparison with conventional two- and three-dimensional T2-weighted turbo spin-echo imaging
    Tanaka, Utaru
    Ueno, Yoshiko
    Morinaga, Yukiko
    Miyake, Hideaki
    Kyotani, Katsusuke
    Ueda, Yu
    Kitajima, Kazuhiro
    Sofue, Keitaro
    Suenaga, Yuko
    Sugimura, Kazuro
    Takahashi, Satoru
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (12) : 707 - 717
  • [28] Improved motion-sensitized driven-equilibrium preparation for 3D turbo spin echo T1 weighted imaging after gadolinium administration for the detection of brain metastases on 3T MRI
    Lee, Sangjoon
    Park, Dong Woo
    Lee, Ji Young
    Lee, Young-Jun
    Kim, Taeyoon
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1063)
  • [29] Elimination of residual blood flow-related signal in 3D volume-selective TSE arterial wall imaging using velocity-sensitive phase reconstruction
    Crowe, LA
    Varghese, A
    Mohiaddin, RH
    Yang, GZ
    Firmin, DN
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (03) : 416 - 421
  • [30] Perirenal lymphatic systems: Evaluation using spectral presaturation with inversion recovery T2-weighted MR images with 3D volume isotropic turbo spin-echo acquisition at 3.0T
    Matsumoto, Shunro
    Mori, Hiromu
    Kiyonaga, Maki
    Yamada, Yasunari
    Takaji, Ryo
    Sato, Fuminori
    Mimata, Hiromitsu
    Hijiya, Naoki
    Moriyama, Masatsugu
    Tanoue, Rika
    Tomonari, Kenichiro
    Matsumoto, Tomohiro
    Hasebe, Terumitsu
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (04) : 897 - 905