Carotid Arterial Wall MRI at 3T Using 3D Variable-Flip-Angle Turbo Spin-Echo (TSE) with Flow-Sensitive Dephasing (FSD)

被引:127
|
作者
Fan, Zhaoyang [1 ,2 ]
Zhang, Zhuoli [1 ]
Chung, Yiu-Cho [3 ]
Weale, Peter [3 ]
Zuehlsdorff, Sven [3 ]
Carr, James [1 ]
Li, Debiao [1 ,2 ]
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Evanston, IL 60208 USA
[3] Siemens Med Solut USA Inc, Chicago, IL USA
关键词
carotid artery; magnetic resonance imaging; atherosclerosis; 3D SPACE; black-blood; RAPID EXTENDED COVERAGE; BLACK-BLOOD MRI; ATHEROSCLEROTIC PLAQUE; MAGNETIC-RESONANCE; 1.5; T; ARTIFACTS; ANGIOGRAPHY; SEQUENCES; CONTRAST; LESIONS;
D O I
10.1002/jmri.22058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the effectiveness of flow-sensitive dephasing (FSD) magnetization preparation in improving blood signal suppression of three-dimensional (3D) turbo spin-echo (TSE) sequence (SPACE) for isotropic high-spatial-resolution carotid arterial wall imaging at 3T. Materials and Methods: The FSD-prepared SPACE sequence (FSD-SPACE) was implemented by adding two identical FSD gradient pulses right before and after the first refocusing 180 degrees-pulse of the SPACE sequence in all three orthogonal directions. Nine healthy volunteers were imaged at 3T with SPACE, FSD-SPACE, and multislice T2-weighted 2D TSE coupled with saturation band (SB-TSE). Apparent carotid wall-lumen contrast-to-noise ratio (aCNR(w-1)) and apparent lumen area (aLA) at the locations with residual-blood (rb) signal shown on SPACE images were compared between SPACE and FSD-SPACE. Carotid aCNR(w-1) and lumen (LA) and wall area (WA) measured from FSD-SPACE were compared to those measured from SB-TSE. Results: Plaque-mimicking flow artifacts identified in seven carotids on SPACE images were eliminated on FSD-SPACE images. The FSD preparation resulted in slightly reduced aCNR(w-1) (P = 0.025), but significantly improved aCNR between the wall and rb regions (P < 0.001) and larger aLA (P < 0.001). Compared to SB-TSE, FSD-SPACE offered comparable aCNR(w-1) with much higher spatial resolution, shorter imaging time, and larger artery coverage. The LA and WA measurements from the two techniques were in good agreement based on intraclasss correlation coefficient (0.988 and 0.949, respectively; P < 0.001) and Bland-Altman analyses. Conclusion: FSD-SPACE is a time-efficient 3D imaging technique for carotid arterial wall with superior spatial resolution and blood signal suppression.
引用
收藏
页码:645 / 654
页数:10
相关论文
共 30 条
  • [1] MRI of intracranial vertebral artery dissection: evaluation of intramural haematoma using a black blood, variable-flip-angle 3D turbo spin-echo sequence
    Takano, Koichi
    Yamashita, Shinnichi
    Takemoto, Koichiro
    Inoue, Tooru
    Kuwabara, Yasuo
    Yoshimitsu, Kengo
    NEURORADIOLOGY, 2013, 55 (07) : 845 - 851
  • [2] Prospective self-gating for swallowing motion: A feasibility study in carotid artery wall MRI using three-dimensional variable-flip-angle turbo spin-echo
    Fan, Zhaoyang
    Zuehlsdorff, Sven
    Liu, Xin
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 490 - 498
  • [3] MRI of intracranial vertebral artery dissection: evaluation of intramural haematoma using a black blood, variable-flip-angle 3D turbo spin-echo sequence
    Koichi Takano
    Shinnichi Yamashita
    Koichiro Takemoto
    Tooru Inoue
    Yasuo Kuwabara
    Kengo Yoshimitsu
    Neuroradiology, 2013, 55 : 845 - 851
  • [4] Characterization of carotid atherosclerosis with black-blood carotid plaque imaging using variable flip-angle 3D turbo spin-echo: Comparison with 2D turbo spin-echo sequences
    Takano, Koichi
    Yamashita, Shinnichi
    Takemoto, Koichiro
    Inoue, Tooru
    Sakata, Noriyuki
    Kuwabara, Yasuo
    Yoshimitsu, Kengo
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) : E304 - E309
  • [5] Carotid arterial wall MRI of apolipoprotein e-deficient mouse at 7 T using DANTE-prepared variable-flip-angle rapid acquisition with relaxation enhancement
    Yang, Yuanbo
    Li, Zhonghao
    Liu, Qiang
    Guo, Yihao
    Mei, Yingjie
    Lyu, Jian
    Zhao, Ming
    Feng, Yanqiu
    Xie, Guoxi
    MAGNETIC RESONANCE IMAGING, 2022, 86 : 1 - 9
  • [6] Comparison of Gated and Ungated Black-Blood Fast Spin-echo MRI of Carotid Vessel Wall at 3T
    Zhu, Chengcheng
    Graves, Martin J.
    Sadat, Umar
    Young, Victoria E.
    Gillard, Jonathan H.
    Patterson, Andrew J.
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2016, 15 (03) : 266 - 272
  • [7] Identification and quantitative evaluation of symptomatic cerebral venous thrombosis using 3D variable flip angle turbo spin echo
    Xiong, Jingtong
    Liu, Ying
    Zhang, Chen
    Chen, Honghai
    Bian, Jie
    Qu, Xiaofeng
    MAGNETIC RESONANCE IMAGING, 2023, 103 : 131 - 138
  • [8] 3D Noncontrast MR Angiography of the Distal Lower Extremities Using Flow-Sensitive Dephasing (FSD)-Prepared Balanced SSFP
    Fan, Zhaoyang
    Sheehan, John
    Bi, Xiaoming
    Liu, Xin
    Carr, James
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (06) : 1523 - 1532
  • [9] MRI of the regions of inner ear and cerebellopontine angle using a 3D T-2-weighted turbo spin-echo sequence: Comparison with conventional 2D T-2-weighted turbo spin-echo sequences and T-1-weighted spin-echo sequences.
    Czerny, C
    Trattnig, S
    Baumgartner, WD
    Gstottner, W
    Imhof, H
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (04): : 377 - 383
  • [10] High resolution imaging of the intracranial vessel wall at 3 and 7 T using 3D fast spin echo MRI
    Zhu, Chengcheng
    Haraldsson, Henrik
    Tian, Bing
    Meisel, Karl
    Ko, Nerissa
    Lawton, Michael
    Grinstead, John
    Ahn, Sinyeob
    Laub, Gerhard
    Hess, Christopher
    Saloner, David
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2016, 29 (03) : 559 - 570