Measurement and prediction of the indoor airflow in a room ventilated with a commercial wind tower

被引:67
作者
Calautit, John Kaiser [1 ]
Hughes, Ben Richard [1 ]
机构
[1] Univ Leeds, Sch Civil Engn, Leeds LS2 9JT, W Yorkshire, England
关键词
Air change effectiveness; Air change rate; CFD; Indoor air quality; Mean age of air; Wind tower/catcher; Wind tunnel; NATURAL VENTILATION; HEAT-TRANSFER; CFD; LOOP; HOT;
D O I
10.1016/j.enbuild.2014.08.015
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper introduces a method for a full assessment of the internal air movement characteristics in a room ventilated with a commercial wind tower using scaled wind tunnel and computational fluid dynamics (CFD) analysis. An accurate geometrical representation of the experimental situation was recreated in the CFD simulation. The experimental investigation was carried out using a closed-loop low speed wind tunnel and the indoor air flow distribution was measured and compared with the CFD analysis. Good correlation between the numerical and experimental results was observed (10% average error). Flow visualisation was also conducted to further analyse the airflow structure within the room. The work assessed several ventilation parameters to describe the indoor airflow characteristics such as the mean age of air (MAA), air change rate, and air change effectiveness (ACE). The MAA was calculated using the steady-state method, by solving an additional partial differential equation describing the transport of the scalar "age of air". The numerical analysis of the MAA allowed to detect less or insufficiently ventilated areas. The CFD code could be useful for the calculation of the MAA and ACE, allowing reduction in time and cost in the evaluation of indoor air quality in buildings ventilated with wind tower or similar device. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:367 / 377
页数:11
相关论文
共 33 条
[1]  
AHSRAE, 1997, 1291997 AHSRAE ANSI
[2]  
AHSRAE, 2005, ASHRAE HDB FUNDAMENT
[3]  
Awbi H.B., 2003, Ventilation of Buildings
[4]  
Calautit J.K., 2014, BUILDING ENV
[5]   Wind tunnel and CFD study of the natural ventilation performance of a commercial multi-directional wind tower [J].
Calautit, John Kaiser ;
Hughes, Ben Richard .
BUILDING AND ENVIRONMENT, 2014, 80 :71-83
[6]   Numerical Investigation of the Integration of Heat Transfer Devices into Wind Towers [J].
Calautit, John Kaiser ;
Hughes, Ben Richard ;
Ghani, Saud .
7TH CONFERENCE ON SUSTAINABLE DEVELOPMENT OF ENERGY, WATER AND ENVIRONMENT SYSTEMS (SDEWES), 2013, 34 :43-48
[7]   A validated design methodology for a closed-loop subsonic wind tunnel [J].
Calautit, John Kaiser ;
Chaudhry, Hassam Nasarullah ;
Hughes, Ben Richard ;
Sim, Lik Fang .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2014, 125 :180-194
[8]   A numerical investigation into the feasibility of integrating green building technologies into row houses in the Middle East [J].
Calautit, John Kaiser ;
Hughes, Ben Richard ;
Ghani, Saud Abdul .
ARCHITECTURAL SCIENCE REVIEW, 2013, 56 (04) :279-296
[9]   CFD analysis of a heat transfer device integrated wind tower system for hot and dry climate [J].
Calautit, John Kaiser ;
Hughes, Ben Richard ;
Chaudhry, Hassam Nasarullah ;
Ghani, Saud Abdul .
APPLIED ENERGY, 2013, 112 :576-591
[10]   Comparison between evaporative cooling and a heat pipe assisted thermal loop for a commercial wind tower in hot and dry climatic conditions [J].
Calautit, John Kaiser ;
Chaudhry, Hassam Nasarullah ;
Hughes, Ben Richard ;
Ghani, Saud Abdul .
APPLIED ENERGY, 2013, 101 :740-755