Primary Robotic-Arm Assisted Total Hip Arthroplasty: An Analysis of 501 Hips With 44-Month Follow-up

被引:8
作者
Domb, Benjamin G. [1 ,2 ,3 ]
Chen, Jeffrey W. [4 ]
Kyin, Cynthia [1 ]
Bheem, Rishika [1 ]
Karom, Jarod [1 ,5 ]
Shapira, Jacob [1 ]
Rosinsky, Philip J. [1 ]
Lall, Ajay C. [1 ,2 ,3 ]
Maldonado, David R. [6 ]
机构
[1] Amer Hip Inst Res Fdn, Chicago, IL USA
[2] Amer Hip Inst, 999 E Touhy Ave, Chicago, IL 60018 USA
[3] AMITA Hlth St Alexius Med Ctr, Hoffman Estates, IL USA
[4] Vanderbilt Univ, Sch Med, Nashville, TN 37212 USA
[5] Univ Alabama, Tuscaloosa, AL USA
[6] Kerlan Jobe Orthopaed Inst, Los Angeles, CA USA
关键词
UNICOMPARTMENTAL KNEE ARTHROPLASTY; DIRECT ANTERIOR; PLACEMENT; RISK; ACCURACY; POSITION;
D O I
10.3928/01477447-20210201-01
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of this study was to report patient-reported outcome measurements in a large group of patients who underwent robotic-arm assisted primary total hip arthroplasty (THA). Prospectively collected data were retrospectively reviewed between April 2012 and May 2017. Primary THAs using the Mako robotic-arm assisted (Mako Surgical Corp [Stryker]) with minimum 2-year follow-up for Harris Hip Score (HHS) and Forgotten Joint Score-12 (FJS-12) were included. Exclusion criteria were body mass index (BMI) of 40 kg/m(2) or greater, age younger than 21 years, workers' compensation, or unwillingness to participate. Visual analog scale (VAS) score for pain and patient satisfaction score were obtained. Intraoperative measurements for leg length, global offset, acetabular inclination, and version were documented. A total of 501 hips were included, with 57.29% of the patients being female. Mean follow-up was 43.99 +/- 15.59 months. Mean age was 58.70 +/- 9.41 years. Mean BMI was 28.41 +/- 4.55 kg/m(2). Mean HHS was 90.87 +/- 13.45, mean FJS-12 was 79.97 +/- 25.87, mean VAS score was 1.20 +/- 2.06, and mean patient satisfaction score was 8.85 +/- 2.08. Intraoperative values for acetabular inclination and version were 40.0 degrees +/- 2.2 degrees and 20.5 degrees +/- 2.4 degrees, respectively. The rate of revision due to instability was 0.2%. Patients who received primary robotic-arm assisted THA reported excellent results at 44-month follow-up for multiple patient-reported outcome measurements. Consistency in acetabular cup placement accuracy was achieved regarding the Lewinnek and Callanan safe zones.
引用
收藏
页码:70 / 76
页数:7
相关论文
共 42 条
[1]   What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component Position [J].
Abdel, Matthew P. ;
von Roth, Philipp ;
Jennings, Matthew T. ;
Hanssen, Arlen D. ;
Pagnano, Mark W. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (02) :386-391
[2]   Outpatient Total Hip Arthroplasty in the United States: A Population-based Comparative Analysis of Complication Rates [J].
Arshi, Armin ;
Leong, Natalie L. ;
Wang, Christopher ;
Buser, Zorica ;
Wang, Jeffrey C. ;
SooHoo, Nelson F. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2019, 27 (02) :61-67
[3]   Robot-assisted total hip arthroplasty [J].
Banerjee, Samik ;
Cherian, Jeffery J. ;
Elmallah, Randa K. ;
Pierce, Todd P. ;
Jauregui, Julio J. ;
Mont, Michael A. .
EXPERT REVIEW OF MEDICAL DEVICES, 2016, 13 (01) :47-56
[4]   Comparison of Minimally Invasive Direct Anterior Versus Posterior Total Hip Arthroplasty Based on Inflammation and Muscle Damage Markers [J].
Bergin, Patrick F. ;
Doppelts, Jason D. ;
Kephart, Curtis J. ;
Benke, Michael T. ;
Graeter, James H. ;
Holmes, Andrew S. ;
Haleem-Smith, Hana ;
Tuan, Rocky S. ;
Unger, Anthony S. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (15) :1392-1398
[5]   Indications for early hip revision surgery in the UK - a re-analysis of NJR data [J].
Bolland, Ben J. ;
Whitehouse, Sarah L. ;
Timperley, A. John .
HIP INTERNATIONAL, 2012, 22 (02) :145-152
[6]   Risk of Complication and Revision Total Hip Arthroplasty Among Medicare Patients with Different Bearing Surfaces [J].
Bozic, Kevin J. ;
Ong, Kevin ;
Lau, Edmund ;
Kurtz, Steven M. ;
Vail, Thomas P. ;
Rubash, Harry E. ;
Berry, Daniel J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (09) :2357-2362
[7]   The John Charnley Award Risk Factors for Cup Malpositioning Quality Improvement Through a Joint Registry at a Tertiary Hospital [J].
Callanan, Mark C. ;
Jarrett, Bryan ;
Bragdon, Charles R. ;
Zurakowski, David ;
Rubash, Harry E. ;
Freiberg, Andrew A. ;
Malchau, Henrik .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) :319-329
[8]  
Clement ND, 2019, BONE JOINT J, V101B, P1063, DOI 10.1302/0301-620X.101B9.BJJ-2018-1658.R1
[9]   Minimum 5-Year Outcomes of Robotic-assisted Primary Total Hip Arthroplasty With a Nested Comparison Against Manual Primary Total Hip Arthroplasty: A Propensity Score-Matched Study [J].
Domb, Benjamin G. ;
Chen, Jeffrey W. ;
Lall, Ajay C. ;
Perets, Itay ;
Maldonado, David R. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2020, 28 (20) :847-856
[10]  
Domb Benjamin G, 2017, Surg Technol Int, V31, P389