Pedestrian-level wind conditions in the space underneath lift-up buildings

被引:34
作者
Zhang, Xuelin [1 ]
Tse, K. T. [1 ]
Weerasuriya, A. U. [1 ]
Kwok, K. C. S. [2 ]
Niu, Jianlei [3 ]
Lin, Zhang [4 ]
Mak, Cheuk Ming [5 ]
机构
[1] Hong Kong Univ Sci & Technol, Dept Civil & Environm Engn, Kowloon, Hong Kong, Peoples R China
[2] Univ Sydney, Sch Civil Engn, Darlington, NSW 2006, Australia
[3] Univ Sydney, Fac Architecture Design & Planning, Darlington, NSW, Australia
[4] City Univ Hong Kong, Div Bldg Sci & Technol, Kowloon, Hong Kong, Peoples R China
[5] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
Lift-up building; Pedestrian wind comfort; Multivariable regression analysis; Wind tunnel test; HONG-KONG; CITY BREATHABILITY; ENVIRONMENT; DESIGN; HIGHRISE; COMFORT; TUNNEL; OPTIMIZATION; ENHANCEMENT; SIMULATION;
D O I
10.1016/j.jweia.2018.05.015
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Lift-up buildings are advantageous in improving the wind circulation in a congested and compact city. However, the wind conditions in the void underneath a lift-up building, also known as the lift-up area, are vital for wind comfort of occupants of lift-up buildings. This study tested 28 lift-up buildings in a boundary layer wind tunnel to assess the influence of key design parameters; height and width of the main structure, and height, width, depth, and the shape of the central core on the wind conditions in the lift-up area. The results of the analyses show a significant influence of building height on the magnitude of wind speeds in the lift-up area while the width of the central core controls the area with low wind speeds. Tall buildings with short lift-up cores have small areas with acceptable pedestrian wind comfort, which can be increased by adopting corner modifications for the central core. The area of acceptable pedestrian wind comfort increases in oblique wind directions as the areas of high (>3.5 m s(-1)) and low (<1.5 m s(-1)) wind speeds are decreased. Finally, a non-linear second-order multivariable regression model is developed to predict pedestrian wind comfort in the lift-up area.
引用
收藏
页码:58 / 69
页数:12
相关论文
共 31 条
[11]  
HKBD (Hong Kong Buildings Department), 2005, 1 SUST DEV STRAT HON
[12]  
HKBD (Hong Kong Buildings Department), 2016, APP152 HKBD
[13]  
HKCEDD (Hong Kong Civil Engineering and Development Department), 2010, GREEN MAST PLAN
[14]  
HKPD (Hong Kong Planning Department), 2006, HONG KONG PLANN STAN
[15]   A SIMPLE OMNIDIRECTIONAL SENSOR FOR WIND-TUNNEL STUDIES OF PEDESTRIAN-LEVEL WINDS [J].
IRWIN, HPAH .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1981, 7 (03) :219-239
[16]   Optimization procedures for enhancement of city breathability using arcade design in a realistic high-rise urban area [J].
Juan, Yu-Hsuan ;
Yang, An-Shik ;
Wen, Chih-Yung ;
Lee, Yee-Ting ;
Wang, Po-Chun .
BUILDING AND ENVIRONMENT, 2017, 121 :247-261
[17]   Detached eddy simulation of pedestrian-level wind and gust around an elevated building [J].
Liu, Jianlin ;
Niu, Jianlei ;
Mak, Cheuk Ming ;
Xia, Qian .
BUILDING AND ENVIRONMENT, 2017, 125 :168-179
[18]  
Melbourne W., 1971, P INT C WIND EFF BUI
[19]   Improving the wind environment in high-density cities by understanding urban morphology and surface roughness: A study in Hong Kong [J].
Ng, Edward ;
Yuan, Chao ;
Chen, Liang ;
Ren, Chao ;
Fung, Jimmy C. H. .
LANDSCAPE AND URBAN PLANNING, 2011, 101 (01) :59-74
[20]  
Penwarden A., 1975, WIND ENV BUILDINGS B