Efficiency of contrast enhanced ultrasound for immediate assessment of ablation status after intraoperative radiofrequency ablation of hepatic malignancies

被引:16
作者
da Silva, N. Platz Batista [1 ]
Beyer, L. P. [1 ]
Hottenrott, M. C. [2 ]
Hackl, C. [2 ]
Schlitt, H. J. [2 ]
Stroszczynski, C. [1 ]
Wiggermann, P. [1 ]
Jung, E. M. [1 ]
机构
[1] Univ Hosp Regensburg, Dept Radiol, Franz Josef Strauss Allee 11, D-93053 Regensburg, Germany
[2] Univ Hosp Regensburg, Dept Surg, Regensburg, Germany
关键词
CEUS; radiofrequency ablation; liver surgery; intraoperative ultrasound; HEPATOCELLULAR-CARCINOMA; THERMAL ABLATION; EFSUMB GUIDELINES; LIVER METASTASES; SURGERY; ELASTOGRAPHY; LESIONS; CEUS; MICROVASCULARIZATION; RECOMMENDATIONS;
D O I
10.3233/CH-179112
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AIM: To evaluate the efficiency of intraoperative contrast enhanced ultrasound (Io-CEUS) for assessment of radiofrequency ablation (RFA) during liver tumor surgery. MATERIAL AND METHODS: Retrospective analysis was performed on a total number of 18 patients out of over 500 patients who underwent combined liver tumor surgery and RFAof 27 hepatic tumors between 02/2011 and 12/2016. Io-CEUS was performed by bolus injections of up to 10 ml sulphur hexaflourid microbubbles for diagnostic purposes. To guide the RFA up to 20 ml microbubbles were applied to monitor the procedure and assess the ablation status finally. A fully avascular area or absence of any residual vascularization intratumorally was considered technical success. These findings were correlated to findings of follow-up imaging results (CEUS, MRI, CT) at least 1 up to 40 months (mean 11 months) after surgery. RESULTS: 13 male and 5 female patients aged between 45-77 years (mean 59.2 +/- 17.1 years) with 26 malignant and one most probable benign hepatic lesion were treated with intraoperative RFA. Io-CEUS detected 23 preoperatively unknown liver lesions leading to a change in therapy in 13/ 18 cases (72,2%). All 27 treated lesions showed an avascular area immediately after RFA. According to follow-up imaging results (1 month - 3 years after surgery, mean follow-up time 11 months), 2/18 patients had local recurrences, 8 patients had distant intrahepatic recurrences or extrahepatic recurrence, 8 patients remained tumor-free. Thereby, a success rate of CEUS guided RFA of 89% could be obtained concerning the targeted liver lesions. CONCLUSION: Modern intraoperative ultrasound using B-mode and Io-CEUS is a valuable tool for optimization of diagnostic and therapeutic intraoperative liver procedures and ablative therapies.
引用
收藏
页码:357 / 368
页数:12
相关论文
共 31 条
[11]   Evaluation of quantitative contrast harmonic imaging to assess malignancy of liver tumors: A prospective controlled two-center study [J].
Jung, E. M. ;
Clevert, D. A. ;
Schreyer, A. G. ;
Schmitt, S. ;
Rennert, J. ;
Kubale, R. ;
Feuerbach, S. ;
Jung, F. .
WORLD JOURNAL OF GASTROENTEROLOGY, 2007, 13 (47) :6356-6364
[12]   Characterization of microvascularization of liver tumor lesions with high resolution linear ultrasound and contrast enhanced ultrasound (CEUS) during surgery: First results [J].
Jung, E. M. ;
Ross, C. J. ;
Rennert, J. ;
Scherer, M. N. ;
Farkas, S. ;
von Breitenbuch, P. ;
Schnitzbauer, A. A. ;
Piso, P. ;
Lamby, P. ;
Menzel, C. ;
Schreyer, A. G. ;
Feuerbach, S. ;
Schlitt, H. J. ;
Loss, M. .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2010, 46 (2-3) :89-99
[13]   Contrast-Enhanced Sonography With Abdominal Virtual Sonography in Monitoring Radiofrequency Ablation of Hepatocellular Carcinoma [J].
Kisaka, Yoshiyasu ;
Hirooka, Masashi ;
Koizumi, Yohei ;
Abe, Masanori ;
Matsuura, Bunzo ;
Hiasa, Yoichi ;
Onji, Morikazu .
JOURNAL OF CLINICAL ULTRASOUND, 2010, 38 (03) :138-144
[14]   Intraoperative radiofrequency ablation for hepatocellular carcinoma in 112 patients with cirrhosis: a surgeon's view [J].
Lee, Jung Yeon ;
Kim, Young Hoon ;
Roh, Young Hoon ;
Roh, Kyung Bin ;
Kim, Kwan Woo ;
Kang, Sung Hwa ;
Baek, Yang Hyun ;
Lee, Sung Wook ;
Han, Sang Young ;
Kwon, Hee Jin ;
Cho, Jin Han .
ANNALS OF SURGICAL TREATMENT AND RESEARCH, 2016, 90 (03) :147-156
[15]  
Lee Seok Joon, 2015, Korean J Hepatobiliary Pancreat Surg, V19, P98, DOI 10.14701/kjhbps.2015.19.3.98
[16]   Intraoperative high resolution linear contrast enhanced ultrasound (IOUS) for detection of microvascularization of malignant liver lesions before surgery or radiofrequeny ablation [J].
Loss, Martin ;
Schneider, Julia ;
Uller, Wibke ;
Wiggermann, P. ;
Scherer, Marcus N. ;
Jung, Wolfgang ;
Schlitt, Hans J. ;
Stroszczynski, Christian ;
Jung, Ernst M. .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2012, 50 (1-2) :65-77
[17]   Comparison of contrast enhanced ultrasound and contrast enhanced CT or MRI in monitoring percutaneous thermal ablation procedure in patients with hepatocellular carcinoma: A multi-center study in China [J].
Lu, Ming-De ;
Yu, Xiao-Ling ;
Li, An-Hua ;
Jiang, Tian-An ;
Chen, Min-Hua ;
Zhao, Bao-Zhen ;
Zhou, Xiao-Dong ;
Wang, Jin-Rui .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (11) :1736-1749
[18]   Intraprocedural contrast-enhanced ultrasound (CEUS) in liver percutaneous radiofrequency ablation: Clinical impact and health technology assessment [J].
Mauri G. ;
Porazzi E. ;
Cova L. ;
Restelli U. ;
Tondolo T. ;
Bonfanti M. ;
Cerri A. ;
Ierace T. ;
Croce D. ;
Solbiati L. .
Insights into Imaging, 2014, 5 (2) :209-216
[19]  
Onkologie L., 2013, DIAGNOSTIK THERAPIE
[20]   Image-Based Monitoring of Magnetic Resonance-Guided Thermoablative Therapies for Liver Tumors [J].
Rempp, Hansjoerg ;
Clasen, Stephan ;
Pereira, Philippe L. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 35 (06) :1281-1294