Relationship between implant stability on the abutment and platform level by means of resonance frequency analysis: A cross-sectional study

被引:6
作者
Lages, Frederico Santos [1 ]
Douglas-de-Oliveira, Dhelfeson Willya [1 ]
Ibelli, Guilherme Siqueira [2 ]
Assaf, Fatimah [2 ]
Queiroz, Thallita Pereira [2 ]
Costa, Fernando Oliveira [1 ]
机构
[1] Univ Fed Minas Gerais, Dept Periodontol, Belo Horizonte, MG, Brazil
[2] Univ Ctr Araraquara, Dept Implantol, Sao Paulo, Brazil
关键词
TITANIUM IMPLANTS; IMMEDIATE; VIVO;
D O I
10.1371/journal.pone.0181873
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Resonance frequency analysis (RFA) has become the main tool used to assess the osseointegration of dental implants. The objective of this study was to verify the relationship between the ISQ values with different prosthetic abutments and with the implant platform. The hypothesis was that ISQ values changes according to the abutment height. Twelve patients were included, whose contribution to the study was 31 dental implants (external hexagon connection implants, 4.1x10 mm). The temporary implant-supported crown and prosthetic components were removed and the following smartpegs were inserted, one at a time: type 1, in the implant platform (G1); type A3, in the microunit component with 1mm transmucosal height (G2) and type A3, in the microunit component with 5mm transmucosal height (G3). In all the smartpegs, RFA measurements were taken on mesial, distal, buccal and lingual surfaces. All evaluations were performed by a single calibrated examiner (ICC = 0.989). Data were analyzed by Friedman and Spearman correlation tests and log-linear marginal regression (p<0.05). The mean age of participants was 52.83 (+/- 3.77) years. There was statistically significant difference (p<0.001) among the mean ISQ of G1 (88.27 +/- 5.70); G2 (72.75 +/- 4.73) and G3 (66.33 +/- 3.67). There was statistically significant negative correlation between the ISQ and the measurement distance (rs:-0.852; p<0.001; R2:0.553). Measurement distance was significantly associated (p< 0.001) with ISQ value in the log-linear regression. The abutment height has a significant impact on resonance frequency analysis measurements. The higher the transmucosal abutment height, the lower the implant stability quotient value. Clinically, the ISQ measured on the abutment cannot be compared with values measured on the implant platform.
引用
收藏
页数:8
相关论文
共 31 条
[1]   Early Loading at 21 Days of Non-Submerged Titanium Implants With a Chemically Modified Sandblasted and Acid-Etched Surface: 3-Year Results of a Prospective Study in the Posterior Mandible [J].
Bornstein, Michael M. ;
Wittneben, Julia-Gabriela ;
Bragger, Urs ;
Buser, Daniel .
JOURNAL OF PERIODONTOLOGY, 2010, 81 (06) :809-818
[2]   Reliability of 2 Implant Stability Measuring Methods in Assessment of Various Periimplant Bone Loss: An In Vitro Study With the Periotest and Osstell Mentor [J].
Choi, Han-Hee ;
Chung, Chae-Heon ;
Kim, Su-Gwan ;
Son, Mee-Kyoung .
IMPLANT DENTISTRY, 2014, 23 (01) :51-56
[3]   Marginal bone resorption around immediate and delayed loaded implants supporting a locator-retained mandibular overdenture. A 1-year randomised controlled trial [J].
Elsyad, M. A. ;
Elsaih, E. A. ;
Khairallah, A. S. .
JOURNAL OF ORAL REHABILITATION, 2014, 41 (08) :608-618
[4]   Immediate and Early Loading of Oxidized Tapered Implants in the Partially Edentulous Maxilla: A 1-Year Prospective Clinical, Radiographic, and Resonance Frequency Analysis Study [J].
Fischer, Kerstin ;
Backstrom, Mats ;
Sennerby, Lars .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2009, 11 (02) :69-80
[5]  
Fitzmaurice G., 2011, Applied Longitudinal Data Analysis, V2nd
[6]   The use of short, wide implants in posterior areas with reduced bone height: A retrospective investigation [J].
Griffin, TJ ;
Cheung, WS .
JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (02) :139-144
[7]  
Gupta Rajiv K, 2011, Indian J Dent Res, V22, P567, DOI 10.4103/0970-9290.90300
[8]   Immediate vs. early loading of SLA implants in the posterior mandible: 5-year results of randomized controlled clinical trial [J].
Kokovic, Vladimir ;
Jung, Ronald ;
Feloutzis, Andreas ;
Todorovic, Vladimir S. ;
Jurisic, Milan ;
Haemmerle, Christoph H. F. .
CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (02) :E114-E119
[9]   The Effect of Healing Abutment Reconnection and Disconnection on Soft and Hard Peri-implant Tissues: A Short-Term Randomized Controlled Clinical Trial [J].
Koutouzis, Theofilos ;
Koutouzis, Giasemi ;
Gadalla, Hana ;
Neiva, Rodrigo .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (03) :807-814
[10]   Osstell Resonance Frequency Measurement Values as a Prognostic Factor in Implant Dentistry [J].
Krafft, Tim ;
Graef, Friedrich ;
Karl, Matthias .
JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (04) :E133-E137