A transducer based on enzyme-induced degradation of thin polymer films monitored by surface plasmon resonance

被引:27
作者
Sumner, C [1 ]
Sabot, A [1 ]
Turner, K [1 ]
Krause, S [1 ]
机构
[1] Univ Sheffield, Dept Chem, Sheffield S3 7HF, S Yorkshire, England
关键词
D O I
10.1021/ac000411y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel transducer based on the dissolution of biodegradable polymer films as a direct result of enzymatic reaction has been developed. Three polymers were investigated for use in the transducer: a poly(ester amide), which is degraded by the proteolytic enzyme alpha -chymotrypsin; a dextran hydrogel, which is degraded by dextranase; and poly(trimethylene) succinate, which is degraded by a lipase. Degradation of the polymer films was monitored by surface plasmon resonance (SPR) and impedance measurements. SPR was shown to be suitable for a greater variety of materials, since it does not require the polymer film to be electrically insulating, Rate of degradation was shown to be directly related to enzyme concentration for each polymer/enzyme couple. The poly(ester amide)alpha -chymotrypsin couple proved to be the most sensitive, Degradation of the films was complete in less than 20 min for enzyme concentrations greater than 9 x 10(-9) mol dm(-3). Enzyme concentrations as low as 4 x 10(-11) mol dm(-3) were detected in less than 30 min. The transducer has great potential for the detection of enzyme concentrations as web as for use in immunosensing where the enzyme degrading the polymer would be the enzyme label.
引用
收藏
页码:5225 / 5232
页数:8
相关论文
共 12 条
  • [1] HETEROCHAIN POLYMERS BASED ON NATURAL AMINO-ACIDS - SYNTHESIS AND ENZYMATIC-HYDROLYSIS OF REGULAR POLY(ESTER AMIDE)S BASED ON BIS(L-PHENYLALANINE) ALPHA,OMEGA-ALKYLENE DIESTERS AND ADIPIC ACID
    ARABULI, N
    TSITLANADZE, G
    EDILASHVILI, L
    KHARADZE, D
    GOGUADZE, T
    BERIDZE, V
    GOMURASHVILI, Z
    KATSARAVA, R
    [J]. MACROMOLECULAR CHEMISTRY AND PHYSICS, 1994, 195 (06) : 2279 - 2289
  • [2] BRONDSTED H, 1995, STP PHARMA SCI, V5, P60
  • [3] Brondsted H, 1995, EUR J PHARM BIOPHARM, V41, P341
  • [4] Dynamic surface events measured by simultaneous probe microscopy and surface plasmon detection
    Chen, XY
    Davies, MC
    Roberts, CJ
    Shakesheff, KM
    Tendler, SJB
    Williams, PM
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (08) : 1451 - 1455
  • [5] Electrochemical sensor for measurement of urea and creatinine in serum based on ac impedance measurement of enzyme-catalyzed polymer transformation
    Ho, WO
    Krause, S
    McNeil, CJ
    Pritchard, JA
    Armstrong, RD
    Athey, D
    Rawson, K
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (10) : 1940 - 1946
  • [6] Surface plasmon resonance sensors: review
    Homola, J
    Yee, SS
    Gauglitz, G
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2) : 3 - 15
  • [7] KURONO Y, 1985, CHEM PHARM BULL, V33, P3966
  • [8] ELECTROCHEMICAL SENSORS BASED ON IMPEDANCE MEASUREMENT OF ENZYME-CATALYZED POLYMER DISSOLUTION - THEORY AND APPLICATIONS
    MCNEIL, CJ
    ATHEY, D
    BALL, M
    HO, WO
    KRAUSE, S
    ARMSTRONG, RD
    WRIGHT, JD
    RAWSON, K
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (21) : 3928 - 3935
  • [9] Use of substrate coated electrodes and AC impedance spectroscopy for the detection of enzyme activity
    Saum, AGE
    Cumming, RH
    Rowell, FJ
    [J]. BIOSENSORS & BIOELECTRONICS, 1998, 13 (05) : 511 - 518
  • [10] Surface design of SPR-based immunosensor for the effective binding of antigen or antibody in the evanescent field using mixed polymer matrix
    Toyama, S
    Shoji, A
    Yoshida, Y
    Yamauchi, S
    Ikariyama, Y
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1998, 52 (1-2) : 65 - 71