Critical parameters in a supported liquid membrane extraction technique for ionizable organic compounds with a stagnant acceptor phase

被引:31
作者
Chimuka, Luke [1 ]
Msagati, Titus A. M. [2 ]
Cukrowska, Ewa [1 ]
Tutu, Hlanganani [1 ]
机构
[1] Univ Witwatersrand, Sch Chem, ZA-2050 Johannesburg, Johannesburg, South Africa
[2] Univ KwaZulu Natal, Sch Chem, ZA-4001 Durban, South Africa
关键词
Supported liquid membrane extraction technique; Critical parameters; Ionizable organic compounds; ENVIRONMENTAL WATER SAMPLES; MASS-TRANSFER; CHROMATOGRAPHY; MICROEXTRACTION; TEMPERATURE; ENRICHMENT; HERBICIDES; AMINES;
D O I
10.1016/j.chroma.2010.01.004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The reviews cover important critical parameters that are often optimized in a supported liquid membrane extraction technique in both flat sheet and hollow fibre designs for ionizable organic molecules. Understanding of these parameters can enable one to predict the behavior of the compound before hand and thus reduce the number of optimization experiments. Moreover, less number of experiments can be also generated using statistical techniques which are now becoming more commonly used. Supported liquid membrane extraction optimal parameters such as the conditions of the pH of the acceptor and donor phases should easily be fixed from the pKa values of the compounds. Other parameters, including the polarity of the compound can help to predict the partitioning into the membrane and the behavior of the compound. The influence of parameters such as temperature on the mass transfer in supported liquid membrane depends on the design of the module, experimental design and type of mass transfer controlling the extraction process. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2318 / 2325
页数:8
相关论文
共 33 条
[11]  
Chimuka L, 2006, ACS SYM SER, V926, P149
[12]   Influence of temperature on mass transfer in an incomplete trapping supported liquid membrane extraction of triazole fungicides [J].
Chimuka, Luke ;
Michel, Monika ;
Cukrowska, Ewa ;
Buszewski, Boguslaw .
JOURNAL OF SEPARATION SCIENCE, 2009, 32 (07) :1043-1050
[13]   Evaluation of flat sheet and hollow fiber supported liquid membranes for fructose pertraction from a mixture of sugars [J].
Di Luccio, M ;
Smith, BD ;
Kida, T ;
Alves, TLM ;
Borges, CP .
DESALINATION, 2002, 148 (1-3) :213-220
[14]   Liquid membrane extraction in analytical sample preparation I.: Principles [J].
Jönsson, JÅ ;
Mathiasson, L .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (05) :318-325
[15]   Liquid membrane extraction in analytical sample preparation II.: Applications [J].
Jönsson, JÅ ;
Mathiasson, L .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (05) :325-334
[16]   MASS-TRANSFER KINETICS FOR ANALYTICAL ENRICHMENT AND SAMPLE PREPARATION USING SUPPORTED LIQUID MEMBRANES IN A FLOW SYSTEM WITH STAGNANT ACCEPTOR LIQUID [J].
JONSSON, JA ;
LOVKVIST, P ;
AUDUNSSON, G ;
NILVE, G .
ANALYTICA CHIMICA ACTA, 1993, 277 (01) :9-24
[17]   Supported liquid membrane work-up in combination with liquid chromatography and electrochemical detection for the determination of chlorinated phenols in natural water samples [J].
Knutsson, M ;
Mathiasson, L ;
Jonsson, JA .
CHROMATOGRAPHIA, 1996, 42 (3-4) :165-170
[18]   Development of a simple hollow fibre supported liquid membrane extraction method to extract and preconcentrate dinitrophenols in environmental samples at ng L-1 level by liquid chromatography [J].
Lezamiz, Jon ;
Jonsson, Jan Ake .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1152 (1-2) :226-233
[19]   Passive extraction and clean-up of phenoxy acid herbicides in samples from a groundwater plume using hollow fiber supported liquid membranes [J].
Liu, Jing-Fu ;
Toraeng, Lars ;
Mayer, Philipp ;
Joensson, Jan Ake .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1160 (1-2) :56-63
[20]  
Megersa N, 2001, J SEP SCI, V24, P567, DOI [10.1002/1615-9314(20010801)24:7<567::AID-JSSC567>3.0.CO