There are many ways in which imaging systems can be evaluated. The aim of the present paper is to provide an overview of a number of selected approaches to evaluating imaging systems, often encountered by the medical physicist, and discuss their validity and reliability. Specifically, it will cover (i) characterisation of an imaging system in terms of its detective quantum efficiency using linear-systems analysis; (ii) attempts to calculate relevant measures directly in images using the Rose model and the pixel signal-to-noise ratio; (iii) task-based methods incorporating human observers such as receiver-operating characteristics and (iv) visual grading-based methods using experienced radiologists as observers.
引用
收藏
页码:26 / 36
页数:11
相关论文
共 69 条
[1]  
Altman DG., 1991, PRACTICAL STAT MED R
[2]   Visual grading characteristics (VGC) analysis:: a non-parametric rank-invariant statistical method for image quality evaluation [J].
Bath, M. ;
Mansson, L. G. .
BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (951) :169-176
[3]   Nodule detection in digital chest radiography:: Part of image background acting as pure noise [J].
Båth, M ;
Håkansson, M ;
Börjesson, S ;
Kheddache, S ;
Grahn, A ;
Bochud, FO ;
Verdun, FR ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :102-108
[4]   Nodule detection in digital chest radiography:: Introduction to the radius chest trial [J].
Båth, M ;
Håkansson, M ;
Börjesson, S ;
Kheddache, S ;
Grahn, A ;
Ruschin, M ;
Tingberg, A ;
Mattsson, S ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :85-91
[5]   Nodule detection in digital chest radiography:: Effect of anatomical noise [J].
Båth, M ;
Håkansson, M ;
Börjesson, S ;
Hoeschen, C ;
Tischenko, O ;
Kheddache, S ;
Vikgren, J ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :109-113
[6]   Evaluation of the imaging properties of two generations of a CCD-based system for digital chest radiography [J].
Båth, M ;
Sund, P ;
Månsson, LG .
MEDICAL PHYSICS, 2002, 29 (10) :2286-2297
[7]  
BATH M, 2003, THESIS GOTEBORG GOTE
[8]   Estimation of the noisy component of anatomical backgrounds [J].
Bochud, FO ;
Valley, JF ;
Verdun, FR ;
Hessler, C ;
Schnyder, P .
MEDICAL PHYSICS, 1999, 26 (07) :1365-1370
[9]   The impact of acoustic noise found within clinical departments on radiology performance [J].
Brennan, Patrick C. ;
Ryan, John ;
Evanoff, Mike ;
Toomey, Rachel ;
O'Beirne, Aaron ;
Manning, David ;
Chakraborty, Dev P. ;
McEntee, Mark .
ACADEMIC RADIOLOGY, 2008, 15 (04) :472-476
[10]   Ambient lighting: Effect of illumination on soft-copy viewing of radiographs of the wrist [J].
Brennan, Patrick C. ;
McEntee, Mark ;
Evanoff, Michael ;
Phillips, Peter ;
O'Connor, William T. ;
Manning, David J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (02) :W177-W180