Biomechanical evaluation of proximal tibia behaviour with the use of femoral stems in revision TKA: An in vitro and finite element analysis

被引:26
|
作者
Completo, A. [1 ]
Rego, A. [1 ]
Fonseca, F. [2 ]
Ramos, A. [1 ]
Relvas, C. [1 ]
Simoes, J. A. [1 ]
机构
[1] Univ Aveiro, Dept Engn Mecan, P-3810193 Aveiro, Portugal
[2] Univ Coimbra, Hosp Univ Coimbra, Fac Med, P-3004504 Coimbra, Portugal
关键词
Revision total knee arthroplasty; Femur; Tibia; Press-fit stem; Cemented stem; Experimental strains; TOTAL KNEE ARTHROPLASTY; BONE-MINERAL DENSITY; CANCELLOUS BONE; FOLLOW-UP; COMPONENTS; CEMENT; ALLOGRAFT; FIXATION; FAILURE; STRAINS;
D O I
10.1016/j.clinbiomech.2009.10.011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Recognized failure mechanisms after revision total knee arthroplasty include failure of fixation, instability and loosening. Thus, extended stems have been used to improve fixation and stability. In clinical cases where the stem is only applied in the femur, a question concerning the structural aspect of tibia may arise: Does a stemmed femur changes the structural behaviour of proximal tibia? It seems, that question has not yet been fully answered and the use of stems in the opposite bone structure requires further analysis. Methods: Proximal cortex strains were measured with tri-axial strain gauges in synthetic tibias for three different types of implanted femurs, with two constrained implants. To assess the strains at the cancellous bone under the tibial tray. it was considered a closest physiological load condition with the use of finite element models. Findings: No significant differences of the mean of the tibial cortex strains for the stemmed femur relatively to the stemless femur were observed. The R 2 and slopes values of the linear regressions between experimental and finite element strains were close to one indicating good correlations. The strain behaviour of cancellous bone under the tibial tray is not completely immune to the use of femoral stem extensions. However, the level of this alteration is relatively small when compared with the strain magnitudes. Interpretation: The main insight given by the present study could probably lie in the fact that the use of femoral stems does not contribute to an increase of the risk of failure of the tibia. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:159 / 165
页数:7
相关论文
共 50 条
  • [41] Biomechanical evaluation of three different configurations of external fixators for treating distal third tibia fracture: Finite element analysis in axial, bending and torsion load
    Wahab, Abdul Hadi Abdul
    Wui, Ng Bing
    Kadir, Mohammed Rafiq Abdul
    Ramlee, Muhammad Hanif
    COMPUTERS IN BIOLOGY AND MEDICINE, 2020, 127 (127)
  • [42] Biomechanical study of two alternative methods for the treatment of vertical femoral neck fractures - A finite element analysis
    Xia, Yutong
    Zhang, Wendong
    Hu, Hai
    Yan, Lianqi
    Zhan, Shi
    Wang, Jingcheng
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 211
  • [43] Performance of modified anatomic plates is comparable to proximal femoral nail, dynamic hip screw and anatomic plates: Finite element and biomechanical testing
    Oken, O. Fuad
    Soydan, Zafer
    Yildirim, A. Ozgur
    Gulcek, Murat
    Ozlu, Korhan
    Ucaner, Ahmet
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (10): : 1077 - 1083
  • [44] Finite Element Analysis of Mechanical Characteristics of Internal Fixation for Treatment of Proximal Femoral Osteolytic Lesions in Children
    Wang, Yi-chen
    Yang, Dan
    Zhao, Li-hua
    Xiao, Bo
    Ma, Qi-chao
    Dong, Liang-chao
    Li, Xiang
    Zhang, Yu-guo
    Zhang, Zi-ming
    Luo, Yi
    ORTHOPAEDIC SURGERY, 2023, 15 (02) : 628 - 638
  • [45] Finite element analysis modelling of proximal femoral fractures, including post-fixation periprosthetic fractures
    Noor, Saqib
    Pridham, Cerianne
    Fawcett, Tim
    Barclay, Mark
    Feng, Y. T.
    Hassan, Oubay
    Pallister, Ian
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (06): : 791 - 795
  • [46] Influence of the proximal screws of buttress plates on the stability of vertical femoral neck fractures: a finite element analysis
    Zhan, Shi
    Jiang, Dajun
    Xu, Jian
    Ling, Ming
    Yang, Kai
    Li, Yuehua
    Jia, Weitao
    Hu, Hai
    Zhang, Changqing
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [47] Proximal femoral bionic nail-a novel internal fixation system for the treatment of femoral neck fractures: a finite element analysis
    Ding, Kai
    Zhu, Yanbin
    Zhang, Yifan
    Li, Yonglong
    Wang, Haicheng
    Li, Jiaxing
    Chen, Wei
    Zhang, Qi
    Zhang, Yingze
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [48] Comparison of in situ and in vitro CT scan-based finite element model predictions of proximal femoral fracture load
    Keyak, JH
    Falkinstein, Y
    MEDICAL ENGINEERING & PHYSICS, 2003, 25 (09) : 781 - 787
  • [49] The use of frictional and bonded contact models in finite element analysis for internal fixation of tibia fracture
    Huzni, Syifaul
    Oktiandar, Fikri
    Fonna, Syarizal
    Rahiem, Fazal
    Angriani, Lilis
    FRATTURA ED INTEGRITA STRUTTURALE-FRACTURE AND STRUCTURAL INTEGRITY, 2022, 16 (61): : 130 - 139
  • [50] BIOMECHANICAL EVALUATION OF LOCKING COMPRESSION PLATE (LCP) VERSUS DYNAMIC COMPRESSION PLATE (DCP): A FINITE ELEMENT ANALYSIS
    Suaimi, Muhammad Khairul Asyraf
    Ab Rashid, Amir Mustakim
    Nasution, Ahmad Kafrawi
    Seng, Gan Hong
    Kadir, Mohammed Rafiq Abdul
    Ramlee, Muhammad Hanif
    JURNAL TEKNOLOGI-SCIENCES & ENGINEERING, 2022, 84 (03): : 125 - 131