Biomechanical evaluation of proximal tibia behaviour with the use of femoral stems in revision TKA: An in vitro and finite element analysis

被引:26
|
作者
Completo, A. [1 ]
Rego, A. [1 ]
Fonseca, F. [2 ]
Ramos, A. [1 ]
Relvas, C. [1 ]
Simoes, J. A. [1 ]
机构
[1] Univ Aveiro, Dept Engn Mecan, P-3810193 Aveiro, Portugal
[2] Univ Coimbra, Hosp Univ Coimbra, Fac Med, P-3004504 Coimbra, Portugal
关键词
Revision total knee arthroplasty; Femur; Tibia; Press-fit stem; Cemented stem; Experimental strains; TOTAL KNEE ARTHROPLASTY; BONE-MINERAL DENSITY; CANCELLOUS BONE; FOLLOW-UP; COMPONENTS; CEMENT; ALLOGRAFT; FIXATION; FAILURE; STRAINS;
D O I
10.1016/j.clinbiomech.2009.10.011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Recognized failure mechanisms after revision total knee arthroplasty include failure of fixation, instability and loosening. Thus, extended stems have been used to improve fixation and stability. In clinical cases where the stem is only applied in the femur, a question concerning the structural aspect of tibia may arise: Does a stemmed femur changes the structural behaviour of proximal tibia? It seems, that question has not yet been fully answered and the use of stems in the opposite bone structure requires further analysis. Methods: Proximal cortex strains were measured with tri-axial strain gauges in synthetic tibias for three different types of implanted femurs, with two constrained implants. To assess the strains at the cancellous bone under the tibial tray. it was considered a closest physiological load condition with the use of finite element models. Findings: No significant differences of the mean of the tibial cortex strains for the stemmed femur relatively to the stemless femur were observed. The R 2 and slopes values of the linear regressions between experimental and finite element strains were close to one indicating good correlations. The strain behaviour of cancellous bone under the tibial tray is not completely immune to the use of femoral stem extensions. However, the level of this alteration is relatively small when compared with the strain magnitudes. Interpretation: The main insight given by the present study could probably lie in the fact that the use of femoral stems does not contribute to an increase of the risk of failure of the tibia. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:159 / 165
页数:7
相关论文
共 50 条
  • [1] Biomechanical evaluation of different reconstructive techniques of proximal tibia in revision total knee arthroplasty: An in-vitro and finite element analysis
    Completo, A.
    Duarte, R.
    Fonseca, F.
    Simoes, J. A.
    Ramos, A.
    Relvas, C.
    CLINICAL BIOMECHANICS, 2013, 28 (03) : 291 - 298
  • [2] Biomechanical Analysis of Femoral Stem Features in Hinged Revision TKA with Valgus or Varus Deformity: A Comparative Finite Elements Study
    Bori, Edoardo
    Innocenti, Bernardo
    APPLIED SCIENCES-BASEL, 2023, 13 (04):
  • [3] Finite Element Analysis for the Treatment of Proximal Femoral Fracture
    Hsu, Ching-Chi
    Lin, Jinn
    Amaritsakul, Yongyut
    Antonius, Takalamesar
    Chao, Ching-Kong
    CMC-COMPUTERS MATERIALS & CONTINUA, 2009, 11 (01): : 1 - 13
  • [4] Do Metaphyseal Cones and Stems Provide Any Biomechanical Advantage for Moderate Contained Tibial Defects in Revision TKA? A Finite-Element Analysis Based on a Cadaver Model
    Quevedo Gonzalez, Fernando J.
    Meyers, Kathleen N.
    Schraut, Nicholas
    Mehrotra, Kapil G.
    Lipman, Joseph D.
    Wright, Timothy M.
    Ast, Michael P.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2021, 479 (11) : 2534 - 2546
  • [5] Biomechanical evaluation of ortho-bridge system and proximal femoral nail antirotation in intertrochanteric fractures with lateral wall fracture based on finite element analysis
    Long, Yuntao
    Liu, Na
    Huang, Xiaomeng
    Liang, Weiming
    Liu, Jianke
    Huang, Zhaozhao
    Zhang, Yanhui
    Wang, Wen
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [6] Biomechanical analysis of proximal tibia bone grafting and the effect of the size of osteotomy using a validated finite element model
    Ng, David Q. K.
    Lim, Chin Tat
    Ramruttun, Amit K.
    Tan, Ken Jin
    Wang, Wilson
    Chong, Desmond Y. R.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2019, 57 (08) : 1823 - 1832
  • [7] A Biomechanical and Finite Element Analysis of Femoral Neck Notching During Hip Resurfacing
    Davis, Edward T.
    Olsen, Michael
    Zdero, Rad
    Papini, Marcello
    Waddell, James P.
    Schemitsch, Emil H.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (04):
  • [8] Biomechanical evaluation of implant techniques for ipsilateral femoral neck and shaft fractures: A finite element analysis
    Xiao, Yukun
    He, Kui
    Tan, Xiaoqi
    Wei, Daiqing
    Yan, Jiyuan
    Yang, Yunkang
    Xiang, Feifan
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2025, 164
  • [9] Is it reasonable to shorten the length of cemented stems? A finite element analysis and biomechanical experiment
    Li, Junyan
    Xiong, Liang
    Lei, Chao
    Wu, Xinyu
    Mao, Xinzhan
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [10] Assessment of the suitability of biodegradable rods for use in posterior lumbar fusion: An in-vitro biomechanical evaluation and finite element analysis
    Tsuang, Fon-Yih
    Hsieh, Yueh-Ying
    Kuo, Yi-Jie
    Chen, Chia-Hsien
    Lin, Feng-Huei
    Chen, Chen-Sheng
    Chiang, Chang-Jung
    PLOS ONE, 2017, 12 (11):