Microdialysis based device for continuous extravascular monitoring of blood glucose

被引:11
作者
Feichtner, Franz [1 ]
Schaller, Roland [1 ]
Fercher, Andreas [1 ]
Ratzer, Maria [1 ]
Ellmerer, Martin [2 ]
Plank, Johannes [2 ]
Krause, Bernd [3 ]
Pieber, Thomas [1 ,2 ]
Schaupp, Lukas [1 ,2 ]
机构
[1] Joanneum Res GmbH, Inst Med Technol & Hlth Management, A-8010 Graz, Austria
[2] Med Univ Graz, Div Endocrinol & Nucl Med, Dept Internal Med, A-8036 Graz, Austria
[3] Gambro Dialysatoren GmbH, D-72379 Hechingen, Germany
关键词
Microdialysis; Sampling; Glucose monitoring; Extravascular; In vitro study; Clinical trial; SUBCUTANEOUS ADIPOSE-TISSUE; INTENSIVE INSULIN THERAPY; INTRAVENOUS MICRODIALYSIS; INTERSTITIAL FLUID; PHARMACOKINETICS; HUMANS; EFFICIENCY; ACCURACY; PROBE;
D O I
10.1007/s10544-010-9396-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Glycemic control of intensive care patients can be beneficial for this patient group but the continuous determination of their glucose concentration is challenging. Current continuous glucose monitoring systems based on the measurement of interstitial fluid glucose concentration struggle with sensitivity losses, resulting from biofouling or inflammation reactions. Their use as decision support systems for the therapeutic treatment is moreover hampered by physiological time delays as well as gradients in glucose concentration between plasma and interstitial fluid. To overcome these drawbacks, we developed and clinically evaluated a system based on microdialysis of whole blood. Venous blood is heparinised at the tip of a double lumen catheter and pumped through a membrane based micro-fluidic device where protein-free microdialysate samples are extracted. Glucose recovery as an indicator of long term stability was studied in vitro with heparinised bovine blood and remained highly stable for 72 h. Clinical performance was tested in a clinical trial in eight healthy volunteers undergoing an oral glucose tolerance test. Glucose concentrations of the new system and the reference method correlated at a level of 0.96 and their mean relative difference was 1.9 +/- 11.2%. Clinical evaluation using Clark's Error Grid analysis revealed that the obtained glucose concentrations were accurate and clinically acceptable in 99.6% of all cases. In conclusion, results of the technical and clinical evaluation suggest that the presented device delivers microdialysate samples suitable for accurate and long term stable continuous glucose monitoring in blood.
引用
收藏
页码:399 / 407
页数:9
相关论文
共 36 条
[1]   Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid [J].
Bantle, JP ;
Thomas, W .
JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1997, 130 (04) :436-441
[2]  
Castejon AM, 1999, J PHARMACOL EXP THER, V291, P960
[3]  
CHEN ZD, 1993, J PHARMACOL TOXICOL, V29, P111
[4]   EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE [J].
CLARKE, WL ;
COX, D ;
GONDERFREDERICK, LA ;
CARTER, W ;
POHL, SL .
DIABETES CARE, 1987, 10 (05) :622-628
[5]   Intravascular source of adenosine during forearm ischemia in humans - Implications for reactive hyperemia [J].
Costa, F ;
Sulur, P ;
Angel, M ;
Cavalcante, J ;
Haile, V ;
Christman, B ;
Biaggioni, I .
HYPERTENSION, 1999, 33 (06) :1453-1457
[6]   Methodological issues in microdialysis sampling for pharmacokinetic studies [J].
de Lange, ECM ;
de Boer, AG ;
Breimer, DD .
ADVANCED DRUG DELIVERY REVIEWS, 2000, 45 (2-3) :125-148
[7]  
Dizdar N, 1999, ACTA NEUROL SCAND, V100, P231
[8]  
Dizdar N, 1999, CLIN CHEM, V45, P1813
[9]   Measurement of glucose and metabolites in subcutaneous adipose tissue during hyperglycemia with microdialysis at various perfusion flow rates [J].
Ekberg, NR ;
Wisniewski, N ;
Brismar, K ;
Ungerstedt, U .
CLINICA CHIMICA ACTA, 2005, 359 (1-2) :53-64
[10]   Clinical evaluation of alternative-site glucose measurements in patients after major cardiac surgery [J].
Ellmerer, M ;
Haluzik, M ;
Blaha, J ;
Kremen, J ;
Svacina, S ;
Toller, W ;
Mader, J ;
Schaupp, L ;
Plank, J ;
Pieber, T .
DIABETES CARE, 2006, 29 (06) :1275-1281