Spatial-resolution enhancement in computed tomography

被引:7
作者
Pan, XC [1 ]
Yu, LF [1 ]
Kao, CM [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
computed tomography (CT); image reconstruction; image resolution;
D O I
10.1109/TMI.2004.840846
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We propose an approach that combines an asymmetric fan-beam configuration and a new reconstruction algorithm to enhancing spatial resolution in computed tomography (CT). The asymmetric configuration can be achieved by changing the center of rotation (COR) from the conventional symmetric configuration. It does not, however, require new detectors and X-ray source nor alter the relative geometry between the detector and the X-ray source. By effectively reducing the distance of the COR to the X-ray source, the asymmetric configuration can increase the effective sampling density in projection data without reducing the size of the field of view (FOV). The proposed algorithm, on the other hand, can reconstruct images directly from data acquired with this asymmetric configuration. We performed numerical studies to demonstrate and validate the proposed acquisition/reconstruction approach. Results in these studies confirm that the proposed approach can lead to enhanced spatial resolution in reconstructed images. The proposed acquisition/reconstruction approach may find applications in micro-CT and industrial CT in which the CORs may be changed.
引用
收藏
页码:246 / 253
页数:8
相关论文
共 11 条
  • [1] ASYMMETRIC FAN TRANSMISSION CT ON SPECT SYSTEMS
    CHANG, W
    LONCARIC, S
    HUANG, G
    SANPITAK, P
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (05) : 913 - 928
  • [2] Transmission CT reconstruction for offset fan beam collimation
    Gilland, DR
    Jaszczak, RJ
    Coleman, RE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) : 1602 - 1606
  • [3] Hsieh J., 2003, Computed tomography: principles, design, artifacts, and recent advances
  • [4] High resolution computed tomography and MRI for monitoring lung tumor growth in mice undergoing radioimmunotherapy: Correlation with histology
    Kennel, SJ
    Davis, IA
    Branning, J
    Pan, HJ
    Kabalka, GW
    Paulus, MJ
    [J]. MEDICAL PHYSICS, 2000, 27 (05) : 1101 - 1107
  • [5] Transmission image reconstruction and redundant information in SPECT with asymmetric fanbeam collimation
    La Rivière, PJ
    Pan, XC
    Gilland, D
    Kao, CM
    Chang, W
    Jaszczak, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1357 - 1363
  • [6] A processing technique for the truncated projections of asymmetric-fan-beam transmission imaging
    Loncaric, S
    Chang, W
    Huang, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (06) : 2292 - 2297
  • [7] Image reconstruction with shift-variant filtration and its implication for noise and resolution properties in fan-beam computed tomography
    Pan, XC
    Yu, LF
    [J]. MEDICAL PHYSICS, 2003, 30 (04) : 590 - 600
  • [8] A new X-ray computed tomography system for laboratory mouse imaging
    Paulus, MJ
    Sari-Sarraf, H
    Gleason, SS
    Bobrek, M
    Hicks, JS
    Johnson, DK
    Behel, JK
    Thompson, LH
    Allen, WC
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 558 - 564
  • [9] Molecular imaging in small animals - Roles for micro-CT
    Ritman, EL
    [J]. JOURNAL OF CELLULAR BIOCHEMISTRY, 2002, : 116 - 124
  • [10] X-ray micro-CT with a displaced detector array
    Wang, G
    [J]. MEDICAL PHYSICS, 2002, 29 (07) : 1634 - 1636