Quantification of perfusion and permeability in breast tumors with a deconvolution-based analysis of second-bolus T1-DCE data

被引:33
作者
Makkat, S. [1 ]
Luypaert, R. [1 ]
Sourbron, S. [1 ]
Stadnik, T. [1 ]
De Mey, J. [1 ]
机构
[1] Vrije Univ Brussels, Dept Radiol, Acad Ziekenhuis, BEFY, B-1090 Brussels, Belgium
关键词
breast tumors; dynamic MRI; blood flow; model-independent quantification; deconvolution;
D O I
10.1002/jmri.20937
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To test the feastibility of using a second-bolus injection, added to a routine breast MRI examination, to measure regionasl perfusion and permeability in human breast tumors. Materials and Methodsd: In 30 pastients with breast tumors, first a routine whole-breast T1-DCE sequence was applied, and the slice where the lesion enhanced maximally was located. At the slice position, T1-weighted MR images were acquired at 0.3-second resolution using a second-bolus dynamic inversion recovery (IR)-prepared turbo field echo (TFE) sequence. A pixel-by-pixel model-independent deconvolution of the relative signal enhancement was performed to estimate the tumor blood fow (TBF), tumor volume of distribution (TV), mean transit time (E). In addition to this pilot study, a first appraisal of its sensitivity of tissue type wa made on the basis of a small patient cohort. Results: In the malignant tumors, the parametric maps clearly delineated tumors from the breast tissue and enabled visualization of the heterogeneity. The deconvolution analysis provided objective para,etric maps of tumor perfusion with a mean TBF (84 +/- 48 mL / 100 mL / minute) in malignant tumors in the high range of literature values. Conclusions: In terms of these perfusion values, our method appears promising to quantitatively characterize tumor pathophysiology. However, the number of patients was limited, and the separation between malignant and benign groups was not clear-cut. Additional parameters generated through compartment modelding may inprove the dtumor differentiation.
引用
收藏
页码:1159 / 1167
页数:9
相关论文
共 42 条
[1]   BREAST-TUMORS - COMPARATIVE ACCURACY OF MR-IMAGING RELATIVE TO MAMMOGRAPHY AND US FOR DEMONSTRATING EXTENT [J].
BOETES, C ;
MUS, RDM ;
HOLLAND, R ;
BARENTSZ, JO ;
STRIJK, SP ;
WOBBES, T ;
HENDRIKS, JHCL ;
RUYS, SHJ .
RADIOLOGY, 1995, 197 (03) :743-747
[2]   MR CHARACTERIZATION OF SUSPICIOUS BREAST-LESIONS WITH A GADOLINIUM-ENHANCED TURBOFLASH SUBTRACTION TECHNIQUE [J].
BOETES, C ;
BARENTSZ, JO ;
MUS, RD ;
VANDERSLUIS, RF ;
VANERNING, LJTO ;
HENDRIKS, JHCL ;
HOLLAND, R ;
RUYS, SHJ .
RADIOLOGY, 1994, 193 (03) :777-781
[3]   Microcirculation and microvasculature in breast tumors: Pharmacokinetic analysis of dynamic MR image series [J].
Brix, G ;
Kiessling, F ;
Lucht, R ;
Darai, S ;
Wasser, K ;
Delorme, S ;
Griebel, J .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (02) :420-429
[4]   Quantification of bolus-tracking MRI: Improved characterization of the tissue residue function using Tikhonov regularization [J].
Calamante, F ;
Gadian, DG ;
Connelly, A .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (06) :1237-1247
[5]  
Calamante F, 2000, MAGN RESON MED, V44, P466, DOI 10.1002/1522-2594(200009)44:3<466::AID-MRM18>3.0.CO
[6]  
2-M
[7]  
Cenic A, 2000, AM J NEURORADIOL, V21, P462
[8]   Quantification of the extraction fraction for gadopentetate across breast cancer capillaries [J].
Daldrup, HE ;
Shames, DM ;
Husseini, W ;
Wendland, MF ;
Okuhata, Y ;
Brasch, RC .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (04) :537-543
[9]  
Degani H, 2003, THROMB HAEMOSTASIS, V89, P25
[10]   Breast cancer: Regional blood flow and blood volume measured with magnetic susceptibility-based MR imaging - Initial results [J].
Delille, JP ;
Slanetz, PJ ;
Yeh, ED ;
Kopans, DB ;
Garrido, L .
RADIOLOGY, 2002, 223 (02) :558-565