Computer Navigation Helps Reduce the Incidence of Noise After Ceramic-on-Ceramic Total Hip Arthroplasty

被引:18
作者
Shah, Siddharth M. [1 ]
Deep, Kamal [1 ]
Siramanakul, Chaiyaporn [1 ,2 ]
Mahajan, Vivek [1 ,3 ]
Picard, Frederic [1 ]
Allen, David J. [1 ]
机构
[1] Golden Jubilee Natl Hosp, Dept Orthopaed, Agamemnon St, Clydebank G81 4DY, Scotland
[2] Banphaeo Hosp, Dept Orthopaed Surg, Bangkok 10120, Thailand
[3] Indian Spinal Injuries Ctr, New Delhi 110070, India
关键词
computer navigation; squeaking; noise; ceramic-on-ceramic; total hip arthroplasty; ACETABULAR COMPONENT ORIENTATION; LEG LENGTH; SQUEAKING; BEARING; RELIABILITY; ACCURATE; VALIDITY; OFFSET;
D O I
10.1016/j.arth.2017.04.019
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Noise after ceramic-on-ceramic (CoC) total hip arthroplasty (THA) is a well-recognized problem. Computer navigation has been shown to achieve desired implant orientation. Our aim was (1) to compare the incidence of noise between navigated and conventional CoC THAs and (2) to determine the factors associated with noise. Methods: All patients undergoing CoC THA between March 2009 and August 2012 were considered for this study. Information regarding hip noise was obtained via telephone or postal interview. A comparable cohort of patients in navigated and conventional groups was used to evaluate the incidence of noise. Results: A total of 375 CoC THAs using the same implant (202 navigated and 173 conventional) were evaluated. Patients <65 years of age had significantly greater incidence of noise (22.4% vs 6.1%; P < .001). To ensure similarity, a subgroup of cohort < 65 years and a 32-mm head size was used to compare the incidence of noise between the navigated (68 THAs) and conventional (118 THAs) groups. Overall incidence of noise was significantly greater in the conventional group (28%) as compared with the navigated group (10%; P = .005). The relative risk of noise for the conventional vs the navigated group was 2.7 (P = .01), and for squeaking was 1.9 (P = .2). Squeaking THAs had significantly lower cup anteversion (13.4 degrees +/- 5.2 degrees) as compared with the silent THAs (17.6 degrees +/- 6.9 degrees; P = .01). Conclusion: Navigated CoC THAs were 2.7 x less likely to have noise as compared with the conventional ones. Squeaking THAs had significantly lower cup anteversion as compared with the silent ones. Patients of age < 65 years had significantly greater incidence of noise after CoC THA. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:2783 / 2787
页数:5
相关论文
共 20 条
[1]   Incidence and Factors Associated with Squeaking in Alumina-on-Alumina THA [J].
Choi, Il-Yong ;
Kim, Yee-Suk ;
Hwang, Kyu-Tae ;
Kim, Young-Ho .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (12) :3234-3239
[2]   Hip Offset in Total Hip Arthroplasty Quantitative Measurement with Navigation [J].
Dastane, Manish ;
Dorr, Lawrence D. ;
Tarwala, Rupesh ;
Wan, Zhinian .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) :429-436
[3]  
Deep K, 2014, ORTHOP TRAUMA, V28, P309
[4]   Leg length discrepancy in computer navigated total hip arthroplasty - how accurate are we? [J].
Ellapparadja, Pregash ;
Mahajan, Vivek ;
Atiya, Sami ;
Sankar, Biju ;
Deep, Kamal .
HIP INTERNATIONAL, 2016, 26 (05) :438-443
[5]   Reproduction of Hip Offset and Leg Length in Navigated Total Hip Arthroplasty: How Accurate Are We? [J].
Ellapparadja, Pregash ;
Mahajan, Vivek ;
Deakin, Angela H. ;
Deep, Kamal .
JOURNAL OF ARTHROPLASTY, 2015, 30 (06) :1002-1007
[6]   Clicking and Squeaking: In Vivo Correlation of Sound and Separation for Different Bearing Surfaces [J].
Glaser, Diana ;
Komistek, Richard D. ;
Cates, Harold E. ;
Mahfouz, Mohamed R. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A :112-120
[7]   High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings [J].
Keurentjes, J. C. ;
Kuipers, R. M. ;
Wever, D. J. ;
Schreurs, B. W. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (06) :1438-1443
[8]   DISLOCATIONS AFTER TOTAL HIP-REPLACEMENT ARTHROPLASTIES [J].
LEWINNEK, GE ;
LEWIS, JL ;
TARR, R ;
COMPERE, CL ;
ZIMMERMAN, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (02) :217-220
[9]   Reliability and Validity of Measuring Acetabular Component Orientation by Plain Anteroposterior Radiographs [J].
Lu, Ming ;
Zhou, Yi-Xin ;
Du, Hui ;
Zhang, Ji ;
Liu, Jian .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (09) :2987-2994
[10]   The incidence of noise generation arising from the large-diameter Delta Motion ceramic total hip bearing [J].
McDonnell, S. M. ;
Boyce, G. ;
Bare, J. ;
Young, D. ;
Shimmin, A. J. .
BONE & JOINT JOURNAL, 2013, 95B (02) :160-165