Automatic baseline correction method for the open-path Fourier transform infrared spectra by using simple iterative averaging

被引:48
作者
Shen, Xianchun [1 ,2 ]
Xu, Liang [1 ]
Ye, Shubin [2 ]
Hu, Rong [2 ]
Jin, Ling [1 ]
Xu, Hanyang [1 ]
Liu, Wenqing [1 ]
机构
[1] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Environm Opt & Technol, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
WAVELET TRANSFORM;
D O I
10.1364/OE.26.00A609
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
It's necessary to remove the baseline from the spectra, which measured by open-path Fourier transform infrared spectrometry, for further spectral analysis such as qualitative and quantitative analysis. An automatic baseline correction method, the Iterative Averaging method, is presented. Baseline corrected by this method is accurate, and it also shows more precise than other methods when it is applied to Fourier Transform Infrared experimental spectra and simulated data. This method solves the key technology of the real-time on-line spectral analysis of OP-FTIR and improves the capability and adaptability of the unsupervised on-line system effectively. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:A609 / A614
页数:6
相关论文
共 16 条
[1]   Automatic Baseline Recognition for the Correction of Large Sets of Spectra Using Continuous Wavelet Transform and Iterative Fitting [J].
Bertinetto, Carlo G. ;
Vuorinen, Tapani .
APPLIED SPECTROSCOPY, 2014, 68 (02) :155-164
[2]   FAST AND PRECISE AUTOMATIC BASE-LINE CORRECTION OF ONE-DIMENSIONAL AND 2-DIMENSIONAL NMR-SPECTRA [J].
DIETRICH, W ;
RUDEL, CH ;
NEUMANN, M .
JOURNAL OF MAGNETIC RESONANCE, 1991, 91 (01) :1-11
[3]   A perfect smoother [J].
Eilers, PHC .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3631-3636
[4]  
Lan TG, 2007, CHIN OPT LETT, V5, P613
[5]   Morphological weighted penalized least squares for background correction [J].
Li, Zhong ;
Zhan, De-Jian ;
Wang, Jia-Jun ;
Huang, Jing ;
Xu, Qing-Song ;
Zhang, Zhi-Min ;
Zheng, Yi-Bao ;
Liang, Yi-Zeng ;
Wang, Hong .
ANALYST, 2013, 138 (16) :4483-4492
[6]   Optimal Choice of Baseline Correction for Multivariate Calibration of Spectra [J].
Liland, Kristian Hovde ;
Almoy, Trygve ;
Mevik, Bjorn-Helge .
APPLIED SPECTROSCOPY, 2010, 64 (09) :1007-1016
[7]   Baseline correction of high resolution spectral profile data based on exponential smoothing [J].
Liu, Xinbo ;
Zhang, Zhimin ;
Liang, Yizeng ;
Sousa, Pedro F. M. ;
Yun, Yonghuan ;
Yu, Ling .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2014, 139 :97-108
[8]   Asymmetric least squares for multiple spectra baseline correction [J].
Peng, Jiangtao ;
Peng, Silong ;
Jiang, An ;
Wei, Jiping ;
Li, Changwen ;
Tan, Jie .
ANALYTICA CHIMICA ACTA, 2010, 683 (01) :63-68
[9]  
Pirzer M., 2008, U.S Pat.,, Patent No. [7359815, US 7,359,815 B2]
[10]   A fully automated iterative moving averaging (AIMA) technique for baseline correction [J].
Prakash, Bhaskaran David ;
Wei, Yap Chun .
ANALYST, 2011, 136 (15) :3130-3135