Improvement in the Operative Temperature Measurement of Radiant Cooling Panels

被引:0
|
作者
Moftakhari, Ardeshir
Novoselac, Atila
机构
来源
ASHRAE TRANSACTIONS 2020, VOL 126 | 2020年 / 126卷
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Radiant systems have the potential for effective environmental control in the indoor space. When properly coupled with a chiller, they improve the chiller's efficiency by utilizing higher water temperature. When considering the interior surface temperatures in the room with radiant panels, they may cause highly non-uniform temperature distribution with the overall lower surface mean radiant temperatures (MRT). For this reason, both air and surface MRT are affecting 1) thermal comfort and 2) space cooling load of radiant systems and should be considered together. When considering overall thermal sensation in the systems comparison, the same room operative temperature (that is based on room air and MRT) should be used instead of the same air temperature, which results in effective lower daily cooling energy demand for radiant systems. However, implementation of operative temperature into the control system of radiant panels can be quite challenging because MRT sensors are prone to inaccurate and non-precise measurements. Typically, combined effect of air and MRT is measured by the globe thermometer, and this globe temperature is varying with the type of globe thermometer, operation condition of radiant systems, and geometry of the room. This study investigates the effect of different operation parameters, such as sensor shape, color, position, solar radiation, proximity to the air distribution systems, in the implementation of the operative temperature control for radiant systems. A set of experiments were carried out in the state-of-the-art Thermal Facade Laboratory at the University of Texas at Austin that enables simultaneous system and envelope performance comparisons. The results show rooms with radiant systems do possess lower mean radiant temperature (MRT) comparing to those with all-air systems. Also, the results indicate positioning the MRT sensor at the room center produce most accurate operative temperature measurement for full-sphere shape. In terms of sensor color, the black generally overestimates and the white underestimates the room operative temperature. Proximity to air distribution systems and exposure to solar radiation also deviate the measured temperature from the actual room operative temperature.
引用
收藏
页码:419 / 426
页数:8
相关论文
共 50 条
  • [21] Numerical Prediction of Mean Radiant Temperature in Radiant Cooling Indoor Environments
    Xing Daoming
    Li Nianping
    JOURNAL OF THERMAL SCIENCE, 2022, 31 (02) : 359 - 369
  • [22] Numerical Prediction of Mean Radiant Temperature in Radiant Cooling Indoor Environments
    Daoming Xing
    Nianping Li
    Journal of Thermal Science, 2022, 31 : 359 - 369
  • [23] Reconstruction of hydronic radiant cooling panels: Conceptual design and numerical simulation
    Xing, Daoming
    Li, Nianping
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2022, 30
  • [24] Erratum to: Study on dynamic variation of dew point temperature at attached air layer of radiant ceiling cooling panels
    Wufeng Jin
    Jingda Ma
    Chen Bi
    Zhiqiang Wang
    Choi Bong Soo
    Pan Gao
    Building Simulation, 2021, 14 : 1861 - 1861
  • [25] Simplified cooling capacity estimation model for top insulated metal ceiling radiant cooling panels
    Jeong, JW
    Mumma, SA
    APPLIED THERMAL ENGINEERING, 2004, 24 (14-15) : 2055 - 2072
  • [26] Thermal environment and thermal comfort built by decoupled radiant cooling units with low radiant cooling temperature
    Liang, Yuying
    Zhang, Nan
    Wu, Huijun
    Xu, Xinhua
    Du, Ke
    Yang, Jianming
    Sun, Qin
    Dong, Kaijun
    Huang, Gongsheng
    BUILDING AND ENVIRONMENT, 2021, 206 (206)
  • [27] Cooling load characteristics of indoor spaces conditioned by decoupled radiant cooling unit with low radiant temperature
    Liang, Yuying
    Zhang, Nan
    Wu, Huijun
    Xu, Xinhua
    Yang, Jianming
    Huang, Gongsheng
    BUILDING SIMULATION, 2022, 15 (12) : 2067 - 2079
  • [28] Cooling load characteristics of indoor spaces conditioned by decoupled radiant cooling unit with low radiant temperature
    Yuying Liang
    Nan Zhang
    Huijun Wu
    Xinhua Xu
    Jianming Yang
    Gongsheng Huang
    Building Simulation, 2022, 15 : 2067 - 2079
  • [29] Experimental evaluation of thermal environment built by decoupled radiant cooling system with low radiant cooling temperature
    Guo, Yanling
    Du, Ke
    Wu, Huijun
    Li, Xuemei
    Huang, Huakun
    Liu, Jia
    Huang, Gongsheng
    Xu, Xinhua
    JOURNAL OF BUILDING ENGINEERING, 2024, 92
  • [30] The theory of measurement of medium radiant temperature
    Hruska, F.
    Annals of DAAAM for 2003 & Proceedings of the 14th International DAAAM Symposium: INTELLIGENT MANUFACTURING & AUTOMATION: FOCUS ON RECONSTRUCTION AND DEVELOPMENT, 2003, : 189 - 190